Effective point of measurement calculations for cylindrical ionization chambers in kilovoltage x-ray beams
- 27 October 2025
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (21) , 215014
Abstract
Objective. Knowledge of the effective point of measurement (EPOM) of ionization chambers is needed in relative dosimetry for kilovoltage x-ray beams. This study used Monte Carlo calculations to determine EPOM of three cylindrical ionization chambers in kilovoltage x-ray beams. Approach. The EGSnrc Monte Carlo code was used for all calculations for central axis depth doses in a water phantom and in the air cavity of cylindrical ionization chambers in water. EPOM shifts were calculated for x-ray beams from 50 kVp to 300 kVp with half value layer (HVL) from 0.07 to 3.5 mm Cu, with field sizes from 5 to 15 cm diameter. Three cylindrical ionization chambers (NE 2571, Exradin A12 and PTW 30013) were realistically modelled in EGSnrc. The EPOM shift value was identified from the minimum deviation in the ratio of the dose-to-water and the dose-to-air in the chamber cavity, following published numerical methods. Main Results. EPOM shifts normalized to the radius (r) of the cylindrical chamber of the air cavity were calculated to be within 0.2 r of the central axis for HVLs between 0.5 and 3.5 mm Cu. For HVLs less than 0.5 mm Cu, the EPOM shift increased with decreasing HVL. The EPOM shift did not change significantly with field size. Once the EPOM shift is applied, residual differences between the dose-to-water depth curves and dose-to-air cavity depth curves were found to be less than 0.5% in most cases. Significance. Monte Carlo calculations confirm a zero EPOM shift for cylindrical ionization chambers in x-ray beams with HVLs greater than 0.5 mm Cu. The calculated EPOM shifts begin to deviate significantly from zero for HVLs less than 0.5 mm Cu. Current recommendations of a uniform zero EPOM shift for cylindrical ionization chambers in kilovoltage x-ray beams may be inadequate for accurate relative dosimetry in the entire medium-energy x-ray range.Keywords
This publication has 21 references indexed in Scilit:
- Experimental investigation of the effective point of measurement for plane‐parallel chambers used in electron beam dosimetryJournal of Applied Clinical Medical Physics, 2023
- SSRMP Recommendations No 9: Reference dosimetry in low and medium energy x-ray beamsZeitschrift für Medizinische Physik, 2023
- Technical Note: SpekPy v2.0—a software toolkit for modeling x‐ray tube spectraMedical Physics, 2021
- A validation of SpekPy: A software toolkit for modelling X-ray tube spectraPhysica Medica, 2020
- Advances in kilovoltage x-ray beam dosimetryPhysics in Medicine & Biology, 2014
- Consistency in reference radiotherapy dosimetry: resolution of an apparent conundrum when60Co is the reference quality for charged-particle and photon beamsPhysics in Medicine & Biology, 2013
- An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurementsPhysics in Medicine & Biology, 2010
- Measurement of percentage depth dose and lateral beam profile for kilovoltage x-ray therapy beamsPhysics in Medicine & Biology, 1997
- Calculations of ion chamber displacement effect corrections for medium-energy X-ray dosimetryPhysics in Medicine & Biology, 1995
- Correction factors for a cylindrical ionization chamber used in medium-energy X-ray beamsPhysics in Medicine & Biology, 1993