Çağrı Havıtçıoğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Çağrı Havıtçıoğlu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Eren Akin
Department of Orthopaedics and Traumatology, Faculty of Medicine Dokuz Eylul University Izmir Turkey
2 shared publications - Mithat İbOlar
Department of Orthopaedics and Traumatology Bitlis State Hospital Bitlis Türkiye
2 shared publications - Onur Hapa
Department of Orthopedics, Dokuz Eylül University Faculty of Medicine, Izmir, Turkey
2 shared publications - Resit Bugra Husemoglu
Department of Biomechanics, Dokuz Eylül University, Institute of Health Sciences, İzmir, Türkiye
2 shared publications - Selahaddin Aydemir
Department of Orthopaedics and Traumatology, Dokuz Eylul University, Izmir, Turkey
2 shared publications - Burak Menderes Akdoğan
Department of Orthopaedics and Traumatology, Rize State Hospital, Rize, Türkiye
1 shared publication
Latest Publications
- 29 October 2026
- Published by Wiley in Arthroscopy
Labral Graft Volume Augmentation and Femoral Remplissage Have Positive Impact on Hip Distraction Stability After Excessive Cam Resection: An Ovine Model
Purpose: To biomechanically assess the effects of femoral remplissage and labral volume augmentation, individually and in combination, on restoring hip distraction stability after excessive cam resection in an ovine model. Methods: Forty‐eight fresh‐frozen ovine hips were randomized into 6 groups (n = 8): (1) remplissage, (2) baseline labral reconstruction, (3) combined baseline reconstruction, (4) increased thickness (2×), (5) combined augmented (2× + remplissage), and (6) excessive thickness (4×). A 10% over‐resection defect was created at the anterosuperior head‐neck junction. Autologous tendon grafts were fixed with 2.0 mm titanium anchors. Distraction testing at 90° flexion was performed under a 200 N load at 60 mm/min. Suction seal strength was defined as the peak resistance force (N) during femoral head separation. Two parameters were calculated: Δ 1 (Postop‐Intact) for residual loss and Δ 2 (Postop‐Excised) for stability recovery. Statistical analysis used Kruskal‐Wallis and Bonferroni‐corrected Mann‐Whitney U tests ( P < .003). Results: Excessive cam resection significantly reduced suction seal strength ( P < .001). The 4× reconstruction and 2× + remplissage groups achieved the best stability restoration (4×: Δ 1 = 0.78 N, Δ 2 = 24.06 N; 2× + remplissage: Δ 1 = 4.53 N, Δ 2 = 23.12 N; both P < .003 vs baseline). Remplissage alone provided partial recovery, whereas baseline reconstruction had the weakest performance (Δ 1 = 11.48 N, Δ 2 = 14.92 N). Increasing graft thickness improved both Δ 1 and Δ 2 , correlating with greater stability recovery. Conclusions: Standard labral reconstruction alone did not fully restore suction seal strength after excessive cam resection. Increasing graft volume improved distractive stability compared with the resected state, and combined 2× labral augmentation with femoral remplissage achieved stability restoration comparable to the 4× reconstruction group. Remplissage alone provided partial recovery but did not consistently restore intact‐level stability. Clinical Relevance: These findings suggest that increased graft thickness and femoral remplissage may improve distractive stability in an ex vivo over‐resection model.
- 29 October 2026
- Published by Wiley in Arthroscopy
Labral Graft Volume Augmentation and Femoral Remplissage Have Positive Impact on Hip Distraction Stability After Excessive Cam Resection: An Ovine Model
Purpose: To biomechanically assess the effects of femoral remplissage and labral volume augmentation, individually and in combination, on restoring hip distraction stability after excessive cam resection in an ovine model. Methods: Forty‐eight fresh‐frozen ovine hips were randomized into 6 groups (n = 8): (1) remplissage, (2) baseline labral reconstruction, (3) combined baseline reconstruction, (4) increased thickness (2×), (5) combined augmented (2× + remplissage), and (6) excessive thickness (4×). A 10% over‐resection defect was created at the anterosuperior head‐neck junction. Autologous tendon grafts were fixed with 2.0 mm titanium anchors. Distraction testing at 90° flexion was performed under a 200 N load at 60 mm/min. Suction seal strength was defined as the peak resistance force (N) during femoral head separation. Two parameters were calculated: Δ 1 (Postop‐Intact) for residual loss and Δ 2 (Postop‐Excised) for stability recovery. Statistical analysis used Kruskal‐Wallis and Bonferroni‐corrected Mann‐Whitney U tests ( P < .003). Results: Excessive cam resection significantly reduced suction seal strength ( P < .001). The 4× reconstruction and 2× + remplissage groups achieved the best stability restoration (4×: Δ 1 = 0.78 N, Δ 2 = 24.06 N; 2× + remplissage: Δ 1 = 4.53 N, Δ 2 = 23.12 N; both P < .003 vs baseline). Remplissage alone provided partial recovery, whereas baseline reconstruction had the weakest performance (Δ 1 = 11.48 N, Δ 2 = 14.92 N). Increasing graft thickness improved both Δ 1 and Δ 2 , correlating with greater stability recovery. Conclusions: Standard labral reconstruction alone did not fully restore suction seal strength after excessive cam resection. Increasing graft volume improved distractive stability compared with the resected state, and combined 2× labral augmentation with femoral remplissage achieved stability restoration comparable to the 4× reconstruction group. Remplissage alone provided partial recovery but did not consistently restore intact‐level stability. Clinical Relevance: These findings suggest that increased graft thickness and femoral remplissage may improve distractive stability in an ex vivo over‐resection model.
- Open Access
- 28 October 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
Interprofessional communication and early rehabilitation practices in orthopaedic surgery: a cross-sectional survey
- 28 October 2026
- Published by Springer Nature in BMC Musculoskeletal Disorders
Open AccessInterprofessional communication and early rehabilitation practices in orthopaedic surgery: a cross-sectional survey
- 7 October 2025
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 53 (13) , 3223-3229
Exploring Various Labral Reconstruction Techniques in an Ovine Hip Model: A Biomechanical Perspective
Background: Labral reconstruction using various graft materials, including autografts and allografts, is gaining popularity to address labral deficiencies. However, the biomechanical effects of graft size, type, and fixation techniques remain underexplored. Purpose/Hypothesis: The purpose was to evaluate the effects of graft size, graft type, tubularization, and anchor number on suction seal force and distractive stability in an ovine hip model. It was hypothesized that larger graft sizes and the use of allografts would improve the suction seal force and distractive stability compared with smaller grafts and fewer anchor numbers, while tubularization would have no significant effect. Study Design: Controlled laboratory study. Methods: A total of 40 sheep hip joints were randomly assigned to 5 groups. Labral excision was performed, followed by reconstruction using autografts or allografts. Ovine extensor tendons were chosen as autografts, whereas labrums from a different ovine hip were used for allografts. For group 1, autografts matching the original labral width were used. For group 2, autografts twice the original labral width were used. For group 3, allografts matching the original labral width were harvested from a different ovine hip. For group 4, autografts matching the original width were fixed with only 2 anchors. For group 5, autografts matching the original width were tubularized before use. Suction seal force was measured before and after reconstruction using an electromechanical testing system. Statistical analyses included Mann-Whitney U and Wilcoxon signed-rank tests ( P < .05). Results: Group 2 showed the highest improvement in suction seal force, outperforming all other groups ( P < .01). Group 4 exhibited the lowest distractive stability among all groups. Tubularization (group 5) did not enhance biomechanical performance ( P = .752). Group 3, reconstructed with an allograft, exhibited suction seal performance most closely approximating that of group 2, with no significant difference between them. Conclusion: The data from the ovine cadaveric model indicate that increasing the graft size enhances the suction sealing force; however, it remains below the measurements observed in an intact labrum. Furthermore, increasing the number of anchors and optimal graft selection improve postoperative biomechanical stability. Clinical Relevance: Optimizing graft size and fixation techniques in labral reconstruction may improve joint stability and suction seal function and may support surgical strategies aimed at improving outcomes and delaying the progression of osteoarthritis in patients with labral defects.
- 7 October 2025
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 53 (13) , 3223-3229
Exploring Various Labral Reconstruction Techniques in an Ovine Hip Model: A Biomechanical Perspective
Background: Labral reconstruction using various graft materials, including autografts and allografts, is gaining popularity to address labral deficiencies. However, the biomechanical effects of graft size, type, and fixation techniques remain underexplored. Purpose/Hypothesis: The purpose was to evaluate the effects of graft size, graft type, tubularization, and anchor number on suction seal force and distractive stability in an ovine hip model. It was hypothesized that larger graft sizes and the use of allografts would improve the suction seal force and distractive stability compared with smaller grafts and fewer anchor numbers, while tubularization would have no significant effect. Study Design: Controlled laboratory study. Methods: A total of 40 sheep hip joints were randomly assigned to 5 groups. Labral excision was performed, followed by reconstruction using autografts or allografts. Ovine extensor tendons were chosen as autografts, whereas labrums from a different ovine hip were used for allografts. For group 1, autografts matching the original labral width were used. For group 2, autografts twice the original labral width were used. For group 3, allografts matching the original labral width were harvested from a different ovine hip. For group 4, autografts matching the original width were fixed with only 2 anchors. For group 5, autografts matching the original width were tubularized before use. Suction seal force was measured before and after reconstruction using an electromechanical testing system. Statistical analyses included Mann-Whitney U and Wilcoxon signed-rank tests ( P < .05). Results: Group 2 showed the highest improvement in suction seal force, outperforming all other groups ( P < .01). Group 4 exhibited the lowest distractive stability among all groups. Tubularization (group 5) did not enhance biomechanical performance ( P = .752). Group 3, reconstructed with an allograft, exhibited suction seal performance most closely approximating that of group 2, with no significant difference between them. Conclusion: The data from the ovine cadaveric model indicate that increasing the graft size enhances the suction sealing force; however, it remains below the measurements observed in an intact labrum. Furthermore, increasing the number of anchors and optimal graft selection improve postoperative biomechanical stability. Clinical Relevance: Optimizing graft size and fixation techniques in labral reconstruction may improve joint stability and suction seal function and may support surgical strategies aimed at improving outcomes and delaying the progression of osteoarthritis in patients with labral defects.