MAMichelle Vanessa Anggarkusuma

Michelle Vanessa Anggarkusuma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michelle Vanessa Anggarkusuma has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimizing Fluid Resuscitation Strategies: A Network Meta-analysis of Effectiveness and Safety for Hemorrhagic Shock Patients in Emergency Settings

    by Fan Maitri Aldian, Visuddho Visuddho, Michelle Vanessa Anggarkusuma, Jesphine Arbi Wijaya, Anthony Camilo Lim, Galen Chandrawira, Yan Efrata Sembiring, Bambang Pujo Semedi, Jeswant Dillon

    Introduction: Hemorrhagic shock is a life-threatening condition and remains a leading cause of death worldwide. Current European guidelines lack recommendations for one fluid type over another in the management of hemorrhagic shock. This study explores the effectiveness and safety of colloids and crystalloids in resuscitation of hemorrhagic shock patients. Methods: We conducted a systematic search in PubMed, Cochrane Cenral Register of Controlled Trials (CENTRAL), Scopus, Web of Science, ProQuest, and Cumulative Index to Nursing and Allied Health Literature (CINAHL) up to January 3, 2024. We performed data analyses using Rstudio v.4.4.1 in Frequentist network meta-analysis with DerSimonian-Laird random-effects model. Subgroup and network meta-regression analyses was also performed in Bayesian methods. We analyzed safety aspects using meta-proportions with generalized linear mixed models models. Results: A total of 3,693 patients from 23 randomized controlled trials were included in this study. Synthetic colloid demonstrated the lowest mortality rate (odds ratio 0.37, 95% CI, 0.15-0.93; P-score = .94) with the lowest fluid input requirement (mean difference -1.02; 95% CI, -1.62 to -0.41; P-score = .75). Subgroup and network meta-regression analysis revealed none of the covariates significantly influenced these two outcomes. Regarding safety aspects, isotonic crystalloid caused the most diverse adverse events, with acute respiratory distress syndrome (prop = 0.067) and overload syndrome (prop = 0.063) being the most common adverse events. Conclusion: This study provides robust evidence favoring the initial use of synthetic colloid in the management of patients with hemorrhagic shock.


  • Open Access

    Diagnostic performance of digital and traditional stethoscopes for detecting pneumonia-associated crackles in pediatric pneumonia patients

    by Muchammad Fahrul Udin, Michelle Vanessa Anggarkusuma, Raymundus Florentino Mariano Pareira, Farah Sajidah, Muhammad Abdul Raziq, Stanley Bulain, Nasim Amar, Hotma Lestari, Muhammad Yusuf, Ery Olivianto, et al.

    Background Advancements in healthcare technology have enabled the development of digital stethoscopes, enhancing auscultation in telemedicine practices. By remotely capturing and transmitting respiratory sounds, these devices improve physical examinations as well as the diagnosis and monitoring of respiratory diseases, particularly in remote or underserved areas. Objective To evaluate the sensitivity and specificity of a piezoelectric sensor-based digital stethoscope compared to a conventional stethoscope in detecting crackles associated with pediatric pneumonia. Methods This prospective comparative study involved 30 randomly selected pediatric pneumonia patients. Two pediatric pulmonologists independently assessed breath sounds in six lung areas using both digital and conventional stethoscopes. Findings were compared to evaluate the digital stethoscope’s sensitivity and specificity in detecting crackles, with the conventional stethoscope serving as the reference standard. Results The digital stethoscope demonstrated high sensitivity (>90%) and specificity (>90%) in detecting crackles, comparable to the conventional stethoscope. Examiner 1 achieved a sensitivity of 93.16%, a specificity of 97.10%, and an accuracy of 94.62%, while Examiner 2 achieved a sensitivity of 90.43%, a specificity of 91.55%, and an accuracy of 90.86%. The study highlights the potential of digital stethoscopes in telemedicine applications, particularly for pediatric respiratory assessments. Conclusion The digital stethoscope shows good diagnostic performance and may be a viable tool for remote auscultation. Its use may improve access to diagnostics in underserved areas or when in-person exams are difficult.