Jonas Smits
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jonas Smits has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
- Antonia Agapi Pontiki
School of Biomedical Engineering & Imaging Sciences, King’s College London, St Thomas Hospital, London SE1 7EH, UK
2 shared publications - Calum Byrne
St Thomas Hospital, London SE1 7EH, UK
2 shared publications - Camille Benoist
Caranx Medical, 400 Promenade des Anglais, 06200 Nice, France
2 shared publications - Carlo Saija
School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
2 shared publications - Emmanuel Vander Poorten
Department of Mechanical Engineering, Katholieke Universiteit (KU) Leuven, Leuven, Belgium
2 shared publications - Eric Sejor
Caranx Medical, 400 Promenade des Anglais, 06200 Nice, France
2 shared publications
Latest Publications
- Open Access
- 16 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 933
Development and Evaluation of a Reusable Self-Healing Ultrasound Phantom for Vascular Access
Ultrasound-guided femoral vascular access (UFVA) is a crucial step in cardiovascular intervention, yet training models remain costly, anatomically limited, or insufficiently durable. This research aimed to develop and evaluate a reusable, self-healing vascularised leg phantom in collaboration with clinicians. This bifurcating vascular model was cast in Plastisol using a customisable silicone mould design. The material exhibited a Shore OO hardness of 18.0 ± 2.2, a speed of sound of 1454 ± 15 m/s, an acoustic attenuation of 1.66 ± 0.02 × 106 kg/m2s, and healed 18G needle lesions within 3 h. Training capabilities were evaluated in a workshop involving 18 medical students: FVA times improved by more than 60% after 5 min of free practice. Qualitative feedback was collected from 31 medical educators via a seven-question Likert survey, with most reporting they would adopt the phantom for teaching. Phantoms cost £7.87 for materials, yet educators valued the models at £100–£500, underscoring its perceived utility. Compared to commercial alternatives, this in-house production approach reduced costs by 10–60 times, achieving comparable durability and anatomical fidelity. This study establishes a scalable, ultra-low-cost method for producing anatomically realistic, self-healing vascular phantoms, validated for effective skill acquisition in both educational and research settings.
- 16 January 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (2) , 933
Open AccessDevelopment and Evaluation of a Reusable Self-Healing Ultrasound Phantom for Vascular Access
Ultrasound-guided femoral vascular access (UFVA) is a crucial step in cardiovascular intervention, yet training models remain costly, anatomically limited, or insufficiently durable. This research aimed to develop and evaluate a reusable, self-healing vascularised leg phantom in collaboration with clinicians. This bifurcating vascular model was cast in Plastisol using a customisable silicone mould design. The material exhibited a Shore OO hardness of 18.0 ± 2.2, a speed of sound of 1454 ± 15 m/s, an acoustic attenuation of 1.66 ± 0.02 × 106 kg/m2s, and healed 18G needle lesions within 3 h. Training capabilities were evaluated in a workshop involving 18 medical students: FVA times improved by more than 60% after 5 min of free practice. Qualitative feedback was collected from 31 medical educators via a seven-question Likert survey, with most reporting they would adopt the phantom for teaching. Phantoms cost £7.87 for materials, yet educators valued the models at £100–£500, underscoring its perceived utility. Compared to commercial alternatives, this in-house production approach reduced costs by 10–60 times, achieving comparable durability and anatomical fidelity. This study establishes a scalable, ultra-low-cost method for producing anatomically realistic, self-healing vascular phantoms, validated for effective skill acquisition in both educational and research settings.
- Open Access
- 17 November 2025
- Published by Springer Nature in Research Square
Development and Evaluation of a Reusable Self-Healing Phantom for Ultrasound-Guided Femoral Vascular Access
Purpose :: Femoral vascular access is a common and often crucial step for cardiovascular intervention. With the growing demand for treatment, increasing pressure is placed on centres to develop new technologies and train more operators. Phantoms have been shown to have positive impacts on training across multiple fields of medicine. Methods :: Using an informed selection of materials, a vascularised leg phantom was developed in collaboration with clinicians. The material properties were investigated and the ability of the phantom to withstand multiple needle punctures was examined. The phantom was then evaluated in a training workshop with 18 medical students, tracking their procedural time before and after 5 minutes of practice. In a separate evaluation, the phantom was demonstrated to 31 medical educators who provided structured feedback using a 7-question survey via a 5-point Likert scale. Results :: Material analysis showed that the phantom had a OO shore hardness of 18.0±2.2, a speed of sound of 1454±15m/s, and could recover from 18-20G needle damage within three hours. Results showed that most students improved their vascular access time by over 60\% after 5 minutes of free practice on the phantom. Most educators said that they would use this phantom for training operators before and whilst training on patients. The total material costs for this phantom were £7.87, yet medical educators valued it at £100-£500 on average. Conclusion :: The methods hereby described propose a viable solution for crafting custom vascular access phantoms for industrial manufacturers, research centres, and training centres with manufacturing capabilities, costing many times less than existing commercial solutions. The phantom was shown to have a positive impact on students, and educators reported they would use it for training. Beyond education, the realistic anatomy, physical properties, and training capabilities achieved with these simple low-cost methods could find numerous applications in academic or industrial research.
- 17 November 2025
- Published by Springer Nature in Research Square
Open AccessDevelopment and Evaluation of a Reusable Self-Healing Phantom for Ultrasound-Guided Femoral Vascular Access
Purpose :: Femoral vascular access is a common and often crucial step for cardiovascular intervention. With the growing demand for treatment, increasing pressure is placed on centres to develop new technologies and train more operators. Phantoms have been shown to have positive impacts on training across multiple fields of medicine. Methods :: Using an informed selection of materials, a vascularised leg phantom was developed in collaboration with clinicians. The material properties were investigated and the ability of the phantom to withstand multiple needle punctures was examined. The phantom was then evaluated in a training workshop with 18 medical students, tracking their procedural time before and after 5 minutes of practice. In a separate evaluation, the phantom was demonstrated to 31 medical educators who provided structured feedback using a 7-question survey via a 5-point Likert scale. Results :: Material analysis showed that the phantom had a OO shore hardness of 18.0±2.2, a speed of sound of 1454±15m/s, and could recover from 18-20G needle damage within three hours. Results showed that most students improved their vascular access time by over 60\% after 5 minutes of free practice on the phantom. Most educators said that they would use this phantom for training operators before and whilst training on patients. The total material costs for this phantom were £7.87, yet medical educators valued it at £100-£500 on average. Conclusion :: The methods hereby described propose a viable solution for crafting custom vascular access phantoms for industrial manufacturers, research centres, and training centres with manufacturing capabilities, costing many times less than existing commercial solutions. The phantom was shown to have a positive impact on students, and educators reported they would use it for training. Beyond education, the realistic anatomy, physical properties, and training capabilities achieved with these simple low-cost methods could find numerous applications in academic or industrial research.
- Open Access
- 21 October 2025
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 12, 1650228
Towards autonomous robot-assisted transcatheter heart valve implantation: in vivo teleoperation and phantom validation of AI-guided positioning
Transcatheter Aortic Valve Implantation (TAVI) is a minimally invasive procedure in which a transcatheter heart valve (THV) is implanted within the patient’s diseased native aortic valve. The procedure is increasingly chosen even for intermediate-risk and younger patients, as it combines complication rates comparable to open-heart surgery with the advantage of being far less invasive. Despite its benefits, challenges remain in achieving accurate and repeatable valve positioning, with inaccuracies potentially leading to complications such as THV migration, coronary obstruction, and conduction disturbances (CD). The latter often requires a permanent pacemaker implantation as a costly and life-changing mitigation. Robotic assistance may offer solutions, enhancing precision, standardization, and reducing radiation exposure for clinicians. This article introduces a novel solution for robot-assisted TAVI, addressing the growing need for skilled clinicians and improving procedural outcomes. We present an in-vivo animal demonstration of robotic-assisted TAVI, showing feasibility of tele-operative instrument control and THV deployment. This, done at safer distances from radiation sources by a single operator. Furthermore, THV positioning and deployment under supervised autonomy is demonstrated on phantom, and shown to be feasible using both camera- and fluoroscopy-based imaging feedback and AI. Finally, an initial operator study probes performance and potential added value of various technology augmentations with respect to a manual expert operator, indicating equivalent to superior accuracy and repeatability using robotic assistance. It is concluded that robot-assisted TAVI is technically feasible in-vivo, and presents a strong case for a clinically meaningful application of level-3 autonomy. These findings support the potential of surgical robotic technology to enhance TAVI accuracy and repeatability, ultimately improving patient outcomes and expanding procedural accessibility.
- 21 October 2025
- Published by Frontiers Media SA in Frontiers in Robotics and AI
- Vol. 12, 1650228
Open AccessTowards autonomous robot-assisted transcatheter heart valve implantation: in vivo teleoperation and phantom validation of AI-guided positioning
Transcatheter Aortic Valve Implantation (TAVI) is a minimally invasive procedure in which a transcatheter heart valve (THV) is implanted within the patient’s diseased native aortic valve. The procedure is increasingly chosen even for intermediate-risk and younger patients, as it combines complication rates comparable to open-heart surgery with the advantage of being far less invasive. Despite its benefits, challenges remain in achieving accurate and repeatable valve positioning, with inaccuracies potentially leading to complications such as THV migration, coronary obstruction, and conduction disturbances (CD). The latter often requires a permanent pacemaker implantation as a costly and life-changing mitigation. Robotic assistance may offer solutions, enhancing precision, standardization, and reducing radiation exposure for clinicians. This article introduces a novel solution for robot-assisted TAVI, addressing the growing need for skilled clinicians and improving procedural outcomes. We present an in-vivo animal demonstration of robotic-assisted TAVI, showing feasibility of tele-operative instrument control and THV deployment. This, done at safer distances from radiation sources by a single operator. Furthermore, THV positioning and deployment under supervised autonomy is demonstrated on phantom, and shown to be feasible using both camera- and fluoroscopy-based imaging feedback and AI. Finally, an initial operator study probes performance and potential added value of various technology augmentations with respect to a manual expert operator, indicating equivalent to superior accuracy and repeatability using robotic assistance. It is concluded that robot-assisted TAVI is technically feasible in-vivo, and presents a strong case for a clinically meaningful application of level-3 autonomy. These findings support the potential of surgical robotic technology to enhance TAVI accuracy and repeatability, ultimately improving patient outcomes and expanding procedural accessibility.
- 28 July 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (2) , 301-309
Combined OCT distance and FBG force sensing cannulation needle for retinal vein cannulation: in vivo animal validation
Retinal vein cannulation is an experimental procedure during which a clot-dissolving drug is injected into an obstructed retinal vein. However, due to the fragility and minute size of retinal veins, such procedure is considered too risky to perform manually. With the aid of surgical robots, key limiting factors such as: unwanted eye rotations, hand tremor and instrument immobilization can be tackled. However, local instrument anatomy distance and force estimation remain unresolved issues. A reliable, real-time local interaction estimation between instrument tip and the retina could be a solution. This paper reports on the development of a combined force and distance sensing cannulation needle, and its experimental validation during in vivo animal trials.
- 28 July 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 14 (2) , 301-309
Combined OCT distance and FBG force sensing cannulation needle for retinal vein cannulation: in vivo animal validation
Retinal vein cannulation is an experimental procedure during which a clot-dissolving drug is injected into an obstructed retinal vein. However, due to the fragility and minute size of retinal veins, such procedure is considered too risky to perform manually. With the aid of surgical robots, key limiting factors such as: unwanted eye rotations, hand tremor and instrument immobilization can be tackled. However, local instrument anatomy distance and force estimation remain unresolved issues. A reliable, real-time local interaction estimation between instrument tip and the retina could be a solution. This paper reports on the development of a combined force and distance sensing cannulation needle, and its experimental validation during in vivo animal trials.
- 24 May 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (10) , 1676-1685
In-Human Robot-Assisted Retinal Vein Cannulation, A World First
Retinal Vein Occlusion (RVO) is a blinding disease caused by one or more occluded retinal veins. Current treatment methods only focus on symptom mitigation rather than targeting a solution for the root cause of the disorder. Retinal vein cannulation is an experimental eye surgical procedure which could potentially cure RVO. Its goal is to dissolve the occlusion by injecting an anticoagulant directly into the blocked vein. Given the scale and the fragility of retinal veins on one end and surgeons’ limited positioning precision on the other, performing this procedure manually is considered to be too risky. The authors have been developing robotic devices and instruments to assist surgeons in performing this therapy in a safe and successful manner. This work reports on the clinical translation of the technology, resulting in the world-first in-human robot-assisted retinal vein cannulation. Four RVO patients have been treated with the technology in the context of a phase I clinical trial. The results show that it is technically feasible to safely inject an anticoagulant into a \(100\,{\mu} {\rm m}\)-thick retinal vein of an RVO patient for a period of 10 min with the aid of the presented robotic technology and instrumentation.- 24 May 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (10) , 1676-1685
In-Human Robot-Assisted Retinal Vein Cannulation, A World First
Retinal Vein Occlusion (RVO) is a blinding disease caused by one or more occluded retinal veins. Current treatment methods only focus on symptom mitigation rather than targeting a solution for the root cause of the disorder. Retinal vein cannulation is an experimental eye surgical procedure which could potentially cure RVO. Its goal is to dissolve the occlusion by injecting an anticoagulant directly into the blocked vein. Given the scale and the fragility of retinal veins on one end and surgeons’ limited positioning precision on the other, performing this procedure manually is considered to be too risky. The authors have been developing robotic devices and instruments to assist surgeons in performing this therapy in a safe and successful manner. This work reports on the clinical translation of the technology, resulting in the world-first in-human robot-assisted retinal vein cannulation. Four RVO patients have been treated with the technology in the context of a phase I clinical trial. The results show that it is technically feasible to safely inject an anticoagulant into a \(100\,{\mu} {\rm m}\)-thick retinal vein of an RVO patient for a period of 10 min with the aid of the presented robotic technology and instrumentation.