Charles B. Suskin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Charles B. Suskin has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Guy M. Genin
NSF Science and Technology Center for Engineering Mechanobiology, Washington University in St. Louis, MO, USA
2 shared publications - Joshua W. Osbun
Neurosurgery, Washington University in Saint Louis School of Medicine, Saint Louis, Missouri, USA
2 shared publications - Michael Y. Qiu
Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine , St. Louis, MO 63110; , St. Louis, MO 63130
2 shared publications - Mohamed Adel Zayed
Washington University in St. Louis
2 shared publications - Chase M. Hartquist
Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine , St. Louis, MO 63110; , St. Louis, MO 63130
1 shared publication - Halle R. Lowe
Division of Neurotechnology, Department of Neurological Surgery, Washington University School of Medicine , St. Louis, MO 63110; , St. Louis, MO 63130
1 shared publication
Latest Publications
- 23 October 2024
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 21 (219) , 20240333
Energy barriers govern catheter herniation during endovascular procedures: a 2.5D vascular flow model analysis
Endovascular procedures rely on navigating guidewires, catheters and other devices through tortuous vasculature to treat disease. A critical challenge in these procedures is catheter herniation, in which the device deviates from its intended path, often irrecoverably. To elucidate the mechanics of herniation, we developed a physical flow model of the aortic arch that enables direct measurement of device curvature during experimentally simulated neuroendovascular procedures conducted from an upper arterial access. Combined with measurements of initial, unstressed device shapes and flexural rigidities, the method enables the experimental estimation of the device bending energies during these simulated procedures. Characteristic energy profiles revealed distinct stages in both herniation and successful navigation, governed by the interplay between device properties and vascular anatomy. A deterministic progression from successful navigation to herniation was identified, with catheter systems following paths determined by measurable energy barriers. Increasing guidewire stiffness or decreasing catheter stiffness reduced the energy barrier for successful navigation while increasing that for herniation. This framework enables the prediction of endovascular herniation risk and offers unique insight into improved device design and clinical decision-making.
- 23 October 2024
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 21 (219) , 20240333
Energy barriers govern catheter herniation during endovascular procedures: a 2.5D vascular flow model analysis
Endovascular procedures rely on navigating guidewires, catheters and other devices through tortuous vasculature to treat disease. A critical challenge in these procedures is catheter herniation, in which the device deviates from its intended path, often irrecoverably. To elucidate the mechanics of herniation, we developed a physical flow model of the aortic arch that enables direct measurement of device curvature during experimentally simulated neuroendovascular procedures conducted from an upper arterial access. Combined with measurements of initial, unstressed device shapes and flexural rigidities, the method enables the experimental estimation of the device bending energies during these simulated procedures. Characteristic energy profiles revealed distinct stages in both herniation and successful navigation, governed by the interplay between device properties and vascular anatomy. A deterministic progression from successful navigation to herniation was identified, with catheter systems following paths determined by measurable energy barriers. Increasing guidewire stiffness or decreasing catheter stiffness reduced the energy barrier for successful navigation while increasing that for herniation. This framework enables the prediction of endovascular herniation risk and offers unique insight into improved device design and clinical decision-making.
- Open Access
Stability of navigation in catheter-based endovascular procedures
Endovascular procedures provide surgeons and other interventionalists with minimally invasive methods to treat vascular diseases by passing guidewires, catheters, sheaths and treatment devices into the vasculature to and navigate toward a treatment site. The efficiency of this navigation affects patient outcomes, but is frequently compromised by catheter “herniation”, in which the catheter-guidewire system bulges out from the intended endovascular pathway so that the interventionalist can no longer advance it. Here, we showed herniation to be a bifurcation phenomenon that can be predicted and controlled using mechanical characterizations of catheter-guidewire systems and patientspecific clinical imaging. We demonstrated our approach in laboratory models and, retrospectively, in patients who underwent procedures involving transradial neurovascular procedures with an endovascular pathway from the wrist, up in the arm, around the aortic arch, and into the neurovasculature. Our analyses identified a mathematical navigation stability criterion that predicted herniation in all of these settings. Results show that herniation can be predicted through bifurcation analysis, and provide a framework for selecting catheter-guidewire systems to avoid herniation in specific patient anatomy.
Open AccessStability of navigation in catheter-based endovascular procedures
Endovascular procedures provide surgeons and other interventionalists with minimally invasive methods to treat vascular diseases by passing guidewires, catheters, sheaths and treatment devices into the vasculature to and navigate toward a treatment site. The efficiency of this navigation affects patient outcomes, but is frequently compromised by catheter “herniation”, in which the catheter-guidewire system bulges out from the intended endovascular pathway so that the interventionalist can no longer advance it. Here, we showed herniation to be a bifurcation phenomenon that can be predicted and controlled using mechanical characterizations of catheter-guidewire systems and patientspecific clinical imaging. We demonstrated our approach in laboratory models and, retrospectively, in patients who underwent procedures involving transradial neurovascular procedures with an endovascular pathway from the wrist, up in the arm, around the aortic arch, and into the neurovasculature. Our analyses identified a mathematical navigation stability criterion that predicted herniation in all of these settings. Results show that herniation can be predicted through bifurcation analysis, and provide a framework for selecting catheter-guidewire systems to avoid herniation in specific patient anatomy.