SSShenxing Shi

Shenxing Shi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shenxing Shi has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Xinzhou Dong

    State Key Laboratory on Power System Department of Electrical Engineering Tsinghua University Beijing 100084 People's Republic of China

    2 shared publications
  • Aoyu Lei

    State Key Laboratory on Power System Department of Electrical Engineering Tsinghua University Beijing 100084 People's Republic of China

    1 shared publication
  • Hongyi Yang

    Ultra High Voltage Branch, State Grid Fujian Electric Power Co., Ltd., Fuzhou 350013, China

    1 shared publication
  • Huina Hong

    Ultra High Voltage Branch, State Grid Fujian Electric Power Co., Ltd., Fuzhou 350013, China

    1 shared publication
  • Kaixin Zhang

    Department of Electrical Engineering, Tsinghua University, Beijing 100084, China

    1 shared publication
  • Sohrab Mirsaeidi

    State Key Laboratory on Power System Department of Electrical Engineering Tsinghua University Beijing 100084 People's Republic of China

    1 shared publication

Latest Publications

  • Open Access

    Wave-Speed-Independent Traveling Wave Fault Location Method for Flexible DC Transmission Lines

    by Huina Hong, Zhiwei Cheng, Hongyi Yang, Kaixin Zhang, Shenxing Shi, Wenjing Zhang, Zhiwei Zhuo, Weifeng Dong

    Accurate fault location in flexible DC transmission lines is essential for ensuring rapid fault clearance and system reliability. However, traditional traveling-wave methods are often affected by wave velocity variations and synchronization errors. To address these issues, this paper proposes an improved double-ended traveling-wave fault location method specifically designed for flexible DC transmission systems. The method utilizes the inherent smoothing reactors of DC lines to simplify the identification of reflected waves and introduces a location algorithm that is independent of wave velocity and synchronous timing accuracy. By integrating the advantages of both single-ended and double-ended approaches, the proposed method significantly enhances location accuracy. Simulation results and comparisons with conventional double-ended methods verify its superiority and robustness.


  • Open Access

    Travelling waves‐based fault location scheme for feeders in power distribution network

    by Shenxing Shi, Aoyu Lei, Xin He, Sohrab Mirsaeidi, Xinzhou Dong

    Fault location in distribution systems is difficult for multiple discontinuities, such as branch and junction points on feeders. This paper proposes a scheme for fault location in distribution systems using network topology information and circuit breaker reclosure‐generating travelling waves. Based on the topology information, the circuit breaker closure‐generating travelling waves can be got through analysis. When a permanent fault occurs, the circuit breaker reclosure‐generating travelling waves contain the information on fault position. In this paper, the difference between the pre‐fault travelling waves and post‐fault travelling waves induced by the breaker reclosing in a feeder, defined as reclosing superimposed travelling waves, is calculated. For the reclosing superimposed travelling waves, the initial travelling wave reflects the fault distance. Subsequently, wavelet transform is applied to extract the travelling wave reflected from the fault point. Finally, the time difference between the reclosing instant and the arrival instant of the reflected travelling wave is employed to calculate the fault distance. In order to verify the effectiveness of the proposed scheme, several simulations were carried out using ATP‐EMTP software. The simulation results indicated that the proposed scheme can be effective in fault location for distributed feeders, regardless of grounding system type.


  • Open Access

    Travelling waves‐based identification of sub‐health condition of feeders in power distribution system

    by Shenxing Shi, Zhonghong Hu, Zhao Ma, Xinzhou Dong

    The majority of faults in power distribution system are caused by natural degradation of feeders. In addition, travelling waves will be generated during degradation of feeders. This study proposes a method based on travelling waves to identify sub‐health condition, which represents the degradation of feeder before the feeder fails into a permanent fault. In the method, traveling waves in the power distribution system are monitored in real time. Then, the location of travelling wave source is determined by the polarity of travelling waves, which is extracted using wavelet transform. Finally, the degradation of feeder is identified when all the other possibilities to generate travelling waves are ruled out using the characteristics of power‐frequency voltages and currents accompanied with travelling waves. Simulation results have verified that the proposed method is feasible and effective.