Guankun Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Guankun Zhao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chao Huo
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication - Dan Sun
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication - Heng Nian
Zhejiang University
1 shared publication - Keqiang Tai
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication - Meng Wang
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication - Penghan Li
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication
Latest Publications
- Open Access
Control Strategy for Enhancing Frequency Support Capability of Renewable Energy Plants Under Asymmetric Grid Voltage Dips
With the increasing penetration of renewable energy generation, large-scale voltage dips may cause significant active power deficits and threaten system frequency stability. To address the issue, this article proposes a two-stage control strategy to enhance the frequency support capability of renewable energy plants by maximizing converter utilization during asymmetric grid voltage dips. First, a qualitative analysis of converter active power capacity considering current capacity constraints under grid faults is conducted to establish the basis for mitigating system-wide active power deficits. Second, individual phase current constraints are formulated for converters under asymmetric voltage conditions to achieve full utilization of converter capacity. Based on this, a two-stage control strategy for renewable energy plants is proposed, where plant-level convex optimization models for both pre-fault and post-fault conditions are established. By optimally allocating current references of converters within the plants, the requirement of grid codes is satisfied, and the overall frequency support capability of plants is effectively improved. Simulation results demonstrate that the proposed strategy raises the system frequency nadir from 49.58 Hz to 49.66 Hz under a minor fault and from 49.06 Hz to 49.11 Hz under a severe fault, confirming its effectiveness in enhancing the frequency support capability of renewable energy plants.
Open AccessControl Strategy for Enhancing Frequency Support Capability of Renewable Energy Plants Under Asymmetric Grid Voltage Dips
With the increasing penetration of renewable energy generation, large-scale voltage dips may cause significant active power deficits and threaten system frequency stability. To address the issue, this article proposes a two-stage control strategy to enhance the frequency support capability of renewable energy plants by maximizing converter utilization during asymmetric grid voltage dips. First, a qualitative analysis of converter active power capacity considering current capacity constraints under grid faults is conducted to establish the basis for mitigating system-wide active power deficits. Second, individual phase current constraints are formulated for converters under asymmetric voltage conditions to achieve full utilization of converter capacity. Based on this, a two-stage control strategy for renewable energy plants is proposed, where plant-level convex optimization models for both pre-fault and post-fault conditions are established. By optimally allocating current references of converters within the plants, the requirement of grid codes is satisfied, and the overall frequency support capability of plants is effectively improved. Simulation results demonstrate that the proposed strategy raises the system frequency nadir from 49.58 Hz to 49.66 Hz under a minor fault and from 49.06 Hz to 49.11 Hz under a severe fault, confirming its effectiveness in enhancing the frequency support capability of renewable energy plants.