Keqiang Tai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Keqiang Tai has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chao Huo
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication - Dan Sun
College of Electrical Engineering, Zhejiang University, Hangzhou 310027, China
1 shared publication - Guankun Zhao
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication - Heng Nian
Zhejiang University
1 shared publication - Meng Wang
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication - Penghan Li
Northwest Branch of State Grid Corporation of China, Xi’an 710048, China
1 shared publication
Latest Publications
- Open Access
Robust Planning of Battery–Hydrogen Hybrid Energy Storage Under Heatwave-Induced Source–Load Uncertainty
Extreme heat events can cause sustained load growth, reduced renewable power output, and increased source–load uncertainty, posing challenges to supply–demand balance in power systems with high renewable penetration. To address hourly power fluctuations and cross-day energy deficits under extreme heat conditions, this study proposes a two-stage robust planning method for coordinated battery–hydrogen energy storage. The proposed method constructs a wind–PV–load uncertainty set based on historical heatwave events, where quantile-based boundaries, disturbance budgets, and variation rate constraints are introduced to characterize adverse source–load variations. The storage capacity configuration and worst-case operation scheduling are integrated into a unified framework and solved using the column-and-constraint generation (C&CG) algorithm. Case studies demonstrate that the proposed method reduces the system load shedding rate to 0.01% and the wind and PV curtailment rate to 3.15%. Compared with no-storage and single-storage schemes, the battery–hydrogen hybrid energy storage system effectively improves system resilience and reduces renewable energy curtailment under heatwave scenarios.
Open AccessRobust Planning of Battery–Hydrogen Hybrid Energy Storage Under Heatwave-Induced Source–Load Uncertainty
Extreme heat events can cause sustained load growth, reduced renewable power output, and increased source–load uncertainty, posing challenges to supply–demand balance in power systems with high renewable penetration. To address hourly power fluctuations and cross-day energy deficits under extreme heat conditions, this study proposes a two-stage robust planning method for coordinated battery–hydrogen energy storage. The proposed method constructs a wind–PV–load uncertainty set based on historical heatwave events, where quantile-based boundaries, disturbance budgets, and variation rate constraints are introduced to characterize adverse source–load variations. The storage capacity configuration and worst-case operation scheduling are integrated into a unified framework and solved using the column-and-constraint generation (C&CG) algorithm. Case studies demonstrate that the proposed method reduces the system load shedding rate to 0.01% and the wind and PV curtailment rate to 3.15%. Compared with no-storage and single-storage schemes, the battery–hydrogen hybrid energy storage system effectively improves system resilience and reduces renewable energy curtailment under heatwave scenarios.
- Open Access
Control Strategy for Enhancing Frequency Support Capability of Renewable Energy Plants Under Asymmetric Grid Voltage Dips
With the increasing penetration of renewable energy generation, large-scale voltage dips may cause significant active power deficits and threaten system frequency stability. To address the issue, this article proposes a two-stage control strategy to enhance the frequency support capability of renewable energy plants by maximizing converter utilization during asymmetric grid voltage dips. First, a qualitative analysis of converter active power capacity considering current capacity constraints under grid faults is conducted to establish the basis for mitigating system-wide active power deficits. Second, individual phase current constraints are formulated for converters under asymmetric voltage conditions to achieve full utilization of converter capacity. Based on this, a two-stage control strategy for renewable energy plants is proposed, where plant-level convex optimization models for both pre-fault and post-fault conditions are established. By optimally allocating current references of converters within the plants, the requirement of grid codes is satisfied, and the overall frequency support capability of plants is effectively improved. Simulation results demonstrate that the proposed strategy raises the system frequency nadir from 49.58 Hz to 49.66 Hz under a minor fault and from 49.06 Hz to 49.11 Hz under a severe fault, confirming its effectiveness in enhancing the frequency support capability of renewable energy plants.
Open AccessControl Strategy for Enhancing Frequency Support Capability of Renewable Energy Plants Under Asymmetric Grid Voltage Dips
With the increasing penetration of renewable energy generation, large-scale voltage dips may cause significant active power deficits and threaten system frequency stability. To address the issue, this article proposes a two-stage control strategy to enhance the frequency support capability of renewable energy plants by maximizing converter utilization during asymmetric grid voltage dips. First, a qualitative analysis of converter active power capacity considering current capacity constraints under grid faults is conducted to establish the basis for mitigating system-wide active power deficits. Second, individual phase current constraints are formulated for converters under asymmetric voltage conditions to achieve full utilization of converter capacity. Based on this, a two-stage control strategy for renewable energy plants is proposed, where plant-level convex optimization models for both pre-fault and post-fault conditions are established. By optimally allocating current references of converters within the plants, the requirement of grid codes is satisfied, and the overall frequency support capability of plants is effectively improved. Simulation results demonstrate that the proposed strategy raises the system frequency nadir from 49.58 Hz to 49.66 Hz under a minor fault and from 49.06 Hz to 49.11 Hz under a severe fault, confirming its effectiveness in enhancing the frequency support capability of renewable energy plants.