Maria Sarkiri
Research Subjects
Maria Sarkiri has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alexis Spiliotopoulos
Akmelogi SMPC Athens Greece
1 shared publication - Aristeidis Hristos Zibis
Department of Anatomy, Faculty of Medicine, School of Health Sciences, University of Thessaly, 41110 Larisa, Greece
1 shared publication - Athanasios Batagiannis
University of Berne
1 shared publication - Charoula Kousiatza
Akmelogi SMPC, 17237 Athens, Greece
1 shared publication - Ermioni D. Pasiou
Laboratory for Testing and Materials, Department of Mechanics, School of Applied Mathematical and Physical Sciences, Zografou Campus, National Technical University of Athens, 157 73 Athens, Greece
1 shared publication - Georgios Banis
Akmelogi SMPC Athens Greece
1 shared publication
Latest Publications
- Open Access
- 31 October 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (4) , e70484
Does the ratio of stem‐to‐femur length matter? A validated finite element analysis
Purpose: Total hip arthroplasty is among the most successful orthopedic procedures; however, approximately 10%–20% of patients require revision surgery within 15–20 years. Potential failure mechanisms at the bone–implant interface include stress shielding and excessive micromotion. This experimental work aims at examining the optimal ratio of femur length and stem length with respect to primary stability and stress shielding effect, employing a validated finite element analysis. Methods: One hundred human femora were reconstructed from computed tomography (CT) scans, and for each femur, 13 personalized cementless stems were designed with varying lengths (70–130 mm, in 5 mm increments), resulting in 1300 finite element models. Each model was analyzed under standardized joint and muscle loading conditions. The model was validated experimentally after cadaveric implantation with digital image correlation (DIC) under static loading. Primary outcomes included micromotion at the bone–implant interface and proximal stress shielding. Optimal stem length was determined as the ratio of stem‐to‐femur length that minimized the combined normalized scores of micromotion and stress shielding. The effect of stem‐to‐femur length ratio was analysed with linear regression. Results: The analysis revealed a correlation between femoral length and stem length. Longer stems provided better initial stability and reduced micromotion. On the other hand, shorter stems demonstrated less proximal stress shielding and a better stress distribution resembling that of the intact femur. The optimal stem length was found to be 18.5% ± 2.7% (mean ± SD) of the femur length in terms of the mean of calculated micromotions and stress shielding, indicating that personalized stem length selection can enhance the bone–implant osseointegration. Conclusion: The selection of a stem length that corresponds proportionally to femoral length can improve primary stability and stress shielding upon implantation, highlighting the importance of enhancing initial fixation in order to extend the lifespan of hip replacements. Level of Evidence: N/A.
- 31 October 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (4) , e70484
Open AccessDoes the ratio of stem‐to‐femur length matter? A validated finite element analysis
Purpose: Total hip arthroplasty is among the most successful orthopedic procedures; however, approximately 10%–20% of patients require revision surgery within 15–20 years. Potential failure mechanisms at the bone–implant interface include stress shielding and excessive micromotion. This experimental work aims at examining the optimal ratio of femur length and stem length with respect to primary stability and stress shielding effect, employing a validated finite element analysis. Methods: One hundred human femora were reconstructed from computed tomography (CT) scans, and for each femur, 13 personalized cementless stems were designed with varying lengths (70–130 mm, in 5 mm increments), resulting in 1300 finite element models. Each model was analyzed under standardized joint and muscle loading conditions. The model was validated experimentally after cadaveric implantation with digital image correlation (DIC) under static loading. Primary outcomes included micromotion at the bone–implant interface and proximal stress shielding. Optimal stem length was determined as the ratio of stem‐to‐femur length that minimized the combined normalized scores of micromotion and stress shielding. The effect of stem‐to‐femur length ratio was analysed with linear regression. Results: The analysis revealed a correlation between femoral length and stem length. Longer stems provided better initial stability and reduced micromotion. On the other hand, shorter stems demonstrated less proximal stress shielding and a better stress distribution resembling that of the intact femur. The optimal stem length was found to be 18.5% ± 2.7% (mean ± SD) of the femur length in terms of the mean of calculated micromotions and stress shielding, indicating that personalized stem length selection can enhance the bone–implant osseointegration. Conclusion: The selection of a stem length that corresponds proportionally to femoral length can improve primary stability and stress shielding upon implantation, highlighting the importance of enhancing initial fixation in order to extend the lifespan of hip replacements. Level of Evidence: N/A.