Bo Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bo Zhang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Qingguo Xie
Huazhong University of Science and Technology
3 shared publications - Ang Li
Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Bingxuan Li
Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei, China
2 shared publications - Lei Fang
Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Lin Wan
School of Software Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Ao Qiu
Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Performance Evaluation of a High-Sensitivity Preclinical PET/CT Scanner
The Trans-PET Explorist 180 Positron Emission Tomography/Computed Tomography (PET/CT) (E180) represents the most recent generation of the RAYCAN preclinical Trans-PET series, incorporating multi voltage threshold (MVT) readout technology. It features a transaxial field of view (FOV) of 160 mm and an axial FOV of 200 mm. This study aims to evaluate the performance of the E180 system according to the National Electrical Manufacturers Association (NEMA) NU4-2008 standards, alongside multi-phantom and animal studies to assess its performance in high-throughput scenarios. Employing 2D-filtered back projection (FBP) reconstruction, the system achieved a transaxial full width at half maximum (FWHM) resolution of (1.69 ± 0.12) mm at the center of the FOV. Derenzo phantom imaging resolved 1.20 mm size features. The peak absolute sensitivity was (7.6 ± 0.16)% within a 350 to 650 keV energy window. Scatter fractions were measured at (16 ± 1.3)%, (28 ± 1.8)%, and (47.0 ± 2.6)%, while peak noise equivalent count rates (NECRs) achieved (1540± 21) kcps at (129±3) MBq, (727±17) kcps at (94±4) MBq, and (100± 11) kcps at (114 ± 2) MBq for mouse-, rat-, and monkey-like phantoms, respectively. In the image quality phantom study, recovery coefficients (RCs) for the 1 mm to 5 mm rods ranged from (11.0±1.7)% to (113.8±2.8)%, with image uniformity of (7.0 ± 0.4)% and spill-over ratios (SORs) of (5.1 ± 1.3)% and (4.2 ± 0.9)% for the water- and air-filled regions, respectively. Dynamic imaging in both individual and multiple mice enabled clear visualization of ¹⁸F-FDG uptake kinetics within major organs, such as the brain and myocardium. Concurrent imaging of two and four image quality phantoms, alongside four mice, demonstrated the system's capability for simultaneous multi-target imaging. These features render the E180 exceptionally suitable for high-throughput dynamic imaging of experimental animals.
- 4 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. PP (24697311) , 1
Performance Evaluation of a High-Sensitivity Preclinical PET/CT Scanner
The Trans-PET Explorist 180 Positron Emission Tomography/Computed Tomography (PET/CT) (E180) represents the most recent generation of the RAYCAN preclinical Trans-PET series, incorporating multi voltage threshold (MVT) readout technology. It features a transaxial field of view (FOV) of 160 mm and an axial FOV of 200 mm. This study aims to evaluate the performance of the E180 system according to the National Electrical Manufacturers Association (NEMA) NU4-2008 standards, alongside multi-phantom and animal studies to assess its performance in high-throughput scenarios. Employing 2D-filtered back projection (FBP) reconstruction, the system achieved a transaxial full width at half maximum (FWHM) resolution of (1.69 ± 0.12) mm at the center of the FOV. Derenzo phantom imaging resolved 1.20 mm size features. The peak absolute sensitivity was (7.6 ± 0.16)% within a 350 to 650 keV energy window. Scatter fractions were measured at (16 ± 1.3)%, (28 ± 1.8)%, and (47.0 ± 2.6)%, while peak noise equivalent count rates (NECRs) achieved (1540± 21) kcps at (129±3) MBq, (727±17) kcps at (94±4) MBq, and (100± 11) kcps at (114 ± 2) MBq for mouse-, rat-, and monkey-like phantoms, respectively. In the image quality phantom study, recovery coefficients (RCs) for the 1 mm to 5 mm rods ranged from (11.0±1.7)% to (113.8±2.8)%, with image uniformity of (7.0 ± 0.4)% and spill-over ratios (SORs) of (5.1 ± 1.3)% and (4.2 ± 0.9)% for the water- and air-filled regions, respectively. Dynamic imaging in both individual and multiple mice enabled clear visualization of ¹⁸F-FDG uptake kinetics within major organs, such as the brain and myocardium. Concurrent imaging of two and four image quality phantoms, alongside four mice, demonstrated the system's capability for simultaneous multi-target imaging. These features render the E180 exceptionally suitable for high-throughput dynamic imaging of experimental animals.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 779-788
Head-to-Head Comparison of Brain Imaging Quality Between Brain-Dedicated PET and Whole-Body PET Based on Phantom and Clinical Data
A comprehensive comparison of imaging quality between the brain-dedicated all-digital PET system, DigitMI i30, and the whole-body DigitMI 930 system was performed using a series of phantom studies and clinical evaluations. Image quality was assessed with the point source and Derenzo phantom for spatial resolution, the National Electrical Manufacturers Association (NEMA) image quality phantom for contrast recovery coefficient and background variability, and the Hoffman phantom for gray-white matter contrast, signal-to-noise ratio (SNR), and coefficient of variation (COV). Clinical data were further analyzed to evaluate gray-white matter contrast, SNR, COV, and image sharpness. The DigitMI i30 achieved finer central spatial resolution (2.0 mm vs. 2.4 mm), although its resolution degraded faster than the DigitMI 930 with radial offset. In NEMA image quality tests, the DigitMI i30 exhibited higher contrast recovery coefficient (77.2% vs. 64.9%) and lower background variability (6.5% vs. 7.2%) for the 10 mm sphere. Hoffman phantom results and clinical data further confirmed its advantages, revealing sharper anatomical detail and improved gray-white matter contrast. These findings demonstrate that the physical advantages of a brain-dedicated PET system translate into clinically meaningful improvements, supporting its value as a precise and reliable tool for neuroimaging.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (5) , 779-788
Head-to-Head Comparison of Brain Imaging Quality Between Brain-Dedicated PET and Whole-Body PET Based on Phantom and Clinical Data
A comprehensive comparison of imaging quality between the brain-dedicated all-digital PET system, DigitMI i30, and the whole-body DigitMI 930 system was performed using a series of phantom studies and clinical evaluations. Image quality was assessed with the point source and Derenzo phantom for spatial resolution, the National Electrical Manufacturers Association (NEMA) image quality phantom for contrast recovery coefficient and background variability, and the Hoffman phantom for gray-white matter contrast, signal-to-noise ratio (SNR), and coefficient of variation (COV). Clinical data were further analyzed to evaluate gray-white matter contrast, SNR, COV, and image sharpness. The DigitMI i30 achieved finer central spatial resolution (2.0 mm vs. 2.4 mm), although its resolution degraded faster than the DigitMI 930 with radial offset. In NEMA image quality tests, the DigitMI i30 exhibited higher contrast recovery coefficient (77.2% vs. 64.9%) and lower background variability (6.5% vs. 7.2%) for the 10 mm sphere. Hoffman phantom results and clinical data further confirmed its advantages, revealing sharper anatomical detail and improved gray-white matter contrast. These findings demonstrate that the physical advantages of a brain-dedicated PET system translate into clinically meaningful improvements, supporting its value as a precise and reliable tool for neuroimaging.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04022
Analytic model of trans-axial sensitivity in cylindrical PET systems based on solid angle
In positron emission tomography (PET), a clear theoretical model describing how system sensitivity varies as a source is moved trans-axially within the field of view (FOV) is lacking. The current understanding and practical intuition often suggest that sensitivity is maximum at the center of the FOV, an assumption reflected in standardized protocols. In this work, we derive an analytic model for the trans-axial-plane sensitivity distribution in a cylindrical PET scanner based on solid angle. The model, formulated as a function of trans-axial offset from the center, is validated through both Monte Carlo simulations and physical experiments on a representative system. We find that the derived theoretical distribution is essentially consistent with simulation and experimental results, revealing a non-intuitive feature: sensitivity increases with trans-axial offset, peaks at the edge of the FOV, and drops off sharply beyond it. This study provides the first closed-form model of trans-axial geometric sensitivity in cylindrical PET scanners, offering a vital benchmark for isolating detector technology improvements and revealing a non-intuitive, offset-dependent sensitivity profile that enables new protocol optimization strategies.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04022
Analytic model of trans-axial sensitivity in cylindrical PET systems based on solid angle
In positron emission tomography (PET), a clear theoretical model describing how system sensitivity varies as a source is moved trans-axially within the field of view (FOV) is lacking. The current understanding and practical intuition often suggest that sensitivity is maximum at the center of the FOV, an assumption reflected in standardized protocols. In this work, we derive an analytic model for the trans-axial-plane sensitivity distribution in a cylindrical PET scanner based on solid angle. The model, formulated as a function of trans-axial offset from the center, is validated through both Monte Carlo simulations and physical experiments on a representative system. We find that the derived theoretical distribution is essentially consistent with simulation and experimental results, revealing a non-intuitive feature: sensitivity increases with trans-axial offset, peaks at the edge of the FOV, and drops off sharply beyond it. This study provides the first closed-form model of trans-axial geometric sensitivity in cylindrical PET scanners, offering a vital benchmark for isolating detector technology improvements and revealing a non-intuitive, offset-dependent sensitivity profile that enables new protocol optimization strategies.