Ömer Karagöz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ömer Karagöz has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Kerem Aybar
Department of Metallurgical and Materials, Faculty of Engineering and Architecture, Eskişehir Osmangazi University, Eskişehir, Türkiye
2 shared publications - Mehmet Canbaz
Department of Civil Engineering, Eskisehir Osmangazi University, 26040 Eskisehir, Türkiye
2 shared publications - Serdal Ünal
Eskişehir Osmangazi Üniversitesi
2 shared publications
Latest Publications
- 19 December 2025
- Published by Eskisehir Osmangazi Universitesi Muhendislik ve Mimarlik Fakultesi Dergisi in Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi
- Vol. 33 (3) , 1997-2004
COMPARATIVE ANALYSIS OF MECHANICAL PROPERTIES OF EPOXY COATED AND UNCOATED REINFORCEMENT BAR
This study aims to enhance the mechanical and bond performance of reinforcing bars embedded in concrete by applying epoxy coatings as a protective layer against external effects. For this purpose, epoxy-coated and uncoated rebars with a diameter of 10 mm and length of 30 cm were embedded into 15×15×15 cm concrete blocks using two different methods: cast-in-place and post-installed with chemical anchoring after curing. Each specimen contained a single rebar, and mechanical tests including yield strength, tensile strength, fracture strength, reduction of area, elongation at break, toughness, modulus of elasticity, and adherence strength were conducted. The results showed that epoxy coating slightly improved mechanical properties such as yield and tensile strength, while enhancing toughness and maintaining sufficient ductility. Although a slight decrease in stiffness and plastic strain capacity was observed, the coating increased the reliability of yield behavior. Most notably, adherence strength was significantly improved by epoxy coating, particularly in post-installed specimens, where an increase of over 30% was recorded. Overall, epoxy coating proved to be an effective solution for improving both mechanical integrity and adhesion performance of reinforcing bars, especially in conditions where chemical durability and long-term performance are critical.
- 19 December 2025
- Published by Eskisehir Osmangazi Universitesi Muhendislik ve Mimarlik Fakultesi Dergisi in Eskişehir Osmangazi Üniversitesi Mühendislik ve Mimarlık Fakültesi Dergisi
- Vol. 33 (3) , 1997-2004
COMPARATIVE ANALYSIS OF MECHANICAL PROPERTIES OF EPOXY COATED AND UNCOATED REINFORCEMENT BAR
This study aims to enhance the mechanical and bond performance of reinforcing bars embedded in concrete by applying epoxy coatings as a protective layer against external effects. For this purpose, epoxy-coated and uncoated rebars with a diameter of 10 mm and length of 30 cm were embedded into 15×15×15 cm concrete blocks using two different methods: cast-in-place and post-installed with chemical anchoring after curing. Each specimen contained a single rebar, and mechanical tests including yield strength, tensile strength, fracture strength, reduction of area, elongation at break, toughness, modulus of elasticity, and adherence strength were conducted. The results showed that epoxy coating slightly improved mechanical properties such as yield and tensile strength, while enhancing toughness and maintaining sufficient ductility. Although a slight decrease in stiffness and plastic strain capacity was observed, the coating increased the reliability of yield behavior. Most notably, adherence strength was significantly improved by epoxy coating, particularly in post-installed specimens, where an increase of over 30% was recorded. Overall, epoxy coating proved to be an effective solution for improving both mechanical integrity and adhesion performance of reinforcing bars, especially in conditions where chemical durability and long-term performance are critical.
- 12 December 2025
- Published by Kirsehir Ahi Evran University in Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi
- Vol. 8 (2) , 100-108
Performance of SIMCON in Structural Retrofitting Under Freeze–Thaw Exposure
This study investigates the freeze-thaw (F-T) durability and mechanical performance of Slurry Infiltrated Mat Concrete (SIMCON) produced with two different binders, Portland cement (CEM I 42.5R) and calcium aluminate cement (CAC). SIMCON composites were fabricated by infiltrating cement pastes into randomly oriented steel wool mats, aiming for improved fiber distribution and matrix-reinforcement interaction. Specimens were subjected to 0, 15, and 30 F-T cycles and evaluated on the basis of unit weight, ultrasonic pulse velocity (UPV), flexural strength, and compressive strength. The results showed that all properties deteriorated with increasing number of cycles; however, CAC-based composites consistently outperformed their CEM I counterparts. After 30 cycles, CAC specimens retained 54% higher compressive strength and exhibited slower deterioration rates in UPV and flexural strength. The superior performance of CAC is attributed to its denser, more stable microstructure and its improved resistance to internal cracking and moisture damage. These findings demonstrate that CAC is a promising binder for SIMCON in infrastructure and retrofit applications exposed to harsh environmental conditions where long-term durability is critical.
- 12 December 2025
- Published by Kirsehir Ahi Evran University in Sürdürülebilir Mühendislik Uygulamaları ve Teknolojik Gelişmeler Dergisi
- Vol. 8 (2) , 100-108
Performance of SIMCON in Structural Retrofitting Under Freeze–Thaw Exposure
This study investigates the freeze-thaw (F-T) durability and mechanical performance of Slurry Infiltrated Mat Concrete (SIMCON) produced with two different binders, Portland cement (CEM I 42.5R) and calcium aluminate cement (CAC). SIMCON composites were fabricated by infiltrating cement pastes into randomly oriented steel wool mats, aiming for improved fiber distribution and matrix-reinforcement interaction. Specimens were subjected to 0, 15, and 30 F-T cycles and evaluated on the basis of unit weight, ultrasonic pulse velocity (UPV), flexural strength, and compressive strength. The results showed that all properties deteriorated with increasing number of cycles; however, CAC-based composites consistently outperformed their CEM I counterparts. After 30 cycles, CAC specimens retained 54% higher compressive strength and exhibited slower deterioration rates in UPV and flexural strength. The superior performance of CAC is attributed to its denser, more stable microstructure and its improved resistance to internal cracking and moisture damage. These findings demonstrate that CAC is a promising binder for SIMCON in infrastructure and retrofit applications exposed to harsh environmental conditions where long-term durability is critical.