Haotian Tan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haotian Tan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Fuzeng Zhang
China Southern Power Grid Electric Power Research Institute Co., Ltd., Guangzhou 510663, China
2 shared publications - Kai Liu
China Southern Power Grid Electric Power Research Institute Co., Ltd., Guangzhou 510700, China
2 shared publications - Lujia Wang
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China
2 shared publications - Tienan Cao
China Southern Power Grid Electric Power Research Institute Co., Ltd., Guangzhou 510700, China
2 shared publications - Wei Lu
China Southern Power Grid Electric Power Research Institute Co., Ltd., Guangzhou 510700, China
2 shared publications - Xiaoguo Chen
China Southern Power Grid Electric Power Research Institute Co., Ltd., Guangzhou 510663, China
2 shared publications
Latest Publications
- Open Access
A Field Verification Denoising Method for Partial Discharge Ultrasonic Sensors Based on IPSO-Optimated Multivariate Variational Mode Decomposition Combined with Improved Wavelet Transforms
Field verification of contact-type ultrasonic sensors enables rapid evaluation of their sensitivity performance, thereby ensuring the accuracy of partial discharge (PD) ultrasonic monitoring results. However, during the verification process, both the standard sensor and the sensor under testing are inevitably affected by ambient noise when receiving verification signals, which can result in significant errors in the verification outcome. To address this issue, a noise suppression method is proposed in this study, which integrates multivariate variational mode decomposition (MVMD) optimized by an improved particle swarm optimization (IPSO) algorithm with a hyperbolic tangent-modulated exponential decay wavelet thresholding technique. First, the IPSO algorithm is employed to automatically optimize the parameters of MVMD. Then, the dominant components of the verification signal are selected based on the energy entropy of each decomposed mode. Subsequently, a novel wavelet threshold function incorporating hyperbolic tangent modulation and exponential decay is constructed and combined with an improved thresholding strategy to denoise the residual noise in the dominant components. Finally, a verification platform based on a real-type transformer is established. Both simulated and measured signals are denoised and subjected to sensitivity verification using the proposed method. Comparative analysis with noise-affected verification results demonstrates that the proposed method effectively suppresses noise in the verification signals and improves the accuracy of the sensitivity verification.
Open AccessA Field Verification Denoising Method for Partial Discharge Ultrasonic Sensors Based on IPSO-Optimated Multivariate Variational Mode Decomposition Combined with Improved Wavelet Transforms
Field verification of contact-type ultrasonic sensors enables rapid evaluation of their sensitivity performance, thereby ensuring the accuracy of partial discharge (PD) ultrasonic monitoring results. However, during the verification process, both the standard sensor and the sensor under testing are inevitably affected by ambient noise when receiving verification signals, which can result in significant errors in the verification outcome. To address this issue, a noise suppression method is proposed in this study, which integrates multivariate variational mode decomposition (MVMD) optimized by an improved particle swarm optimization (IPSO) algorithm with a hyperbolic tangent-modulated exponential decay wavelet thresholding technique. First, the IPSO algorithm is employed to automatically optimize the parameters of MVMD. Then, the dominant components of the verification signal are selected based on the energy entropy of each decomposed mode. Subsequently, a novel wavelet threshold function incorporating hyperbolic tangent modulation and exponential decay is constructed and combined with an improved thresholding strategy to denoise the residual noise in the dominant components. Finally, a verification platform based on a real-type transformer is established. Both simulated and measured signals are denoised and subjected to sensitivity verification using the proposed method. Comparative analysis with noise-affected verification results demonstrates that the proposed method effectively suppresses noise in the verification signals and improves the accuracy of the sensitivity verification.
- Open Access
Research on a Degradation Identification Method for GIS UHF Partial Discharge Sensors Based on S-Parameters
The ultra-high-frequency (UHF) detection method is highly accurate and has a fault localization function. At present, most gas-insulated switchgear (GIS) installations are equipped with online UHF monitoring devices to detect partial discharges. In order to ensure the accuracy of the detection results, UHF sensors need to be verified regularly. UHF sensors used for online monitoring are usually installed at the handhole of the GIS and cannot be removed. Measuring the laboratory verification indexes (e.g., equivalent height, dynamic range, etc.) of the sensors directly is very difficult. However, it is easier to measure S11 of the sensor for verification and S21 between it and the neighboring sensors by injecting power signals. Accordingly, this paper proposes a degradation identification method for GIS UHF sensors using a cross-comparison of S-parameters. When sensor sensitivity decreases, S11 increases while S21 decreases, both serving as effective indicators of performance degradation. In this study, the equivalent S-parameter network and the variation mechanisms of S11 and S21 during sensor verification were first analyzed. Normal and typically degraded sensor models were then constructed and coupled in different GIS structures for electromagnetic simulation. The simulation and on-site verification results show that S11 is mainly affected by the sensor’s intrinsic performance and installation conditions at the inspection port, whereas S21 is predominantly influenced by sensor performance and the propagation characteristics of the GIS structure. Through cross-comparison of S11 and S21 at corresponding positions across three phases, sensor aging or failure can be effectively identified, enabling rapid on-site verification without removing the sensors. The proposed method was successfully validated on actual GIS equipment at the China Southern Power Grid Research Institute. It exhibits high accuracy, efficiency, and strong engineering applicability, enabling the early detection of degraded sensors and providing valuable support for condition assessment and maintenance decision-making in GIS online monitoring systems.
Open AccessResearch on a Degradation Identification Method for GIS UHF Partial Discharge Sensors Based on S-Parameters
The ultra-high-frequency (UHF) detection method is highly accurate and has a fault localization function. At present, most gas-insulated switchgear (GIS) installations are equipped with online UHF monitoring devices to detect partial discharges. In order to ensure the accuracy of the detection results, UHF sensors need to be verified regularly. UHF sensors used for online monitoring are usually installed at the handhole of the GIS and cannot be removed. Measuring the laboratory verification indexes (e.g., equivalent height, dynamic range, etc.) of the sensors directly is very difficult. However, it is easier to measure S11 of the sensor for verification and S21 between it and the neighboring sensors by injecting power signals. Accordingly, this paper proposes a degradation identification method for GIS UHF sensors using a cross-comparison of S-parameters. When sensor sensitivity decreases, S11 increases while S21 decreases, both serving as effective indicators of performance degradation. In this study, the equivalent S-parameter network and the variation mechanisms of S11 and S21 during sensor verification were first analyzed. Normal and typically degraded sensor models were then constructed and coupled in different GIS structures for electromagnetic simulation. The simulation and on-site verification results show that S11 is mainly affected by the sensor’s intrinsic performance and installation conditions at the inspection port, whereas S21 is predominantly influenced by sensor performance and the propagation characteristics of the GIS structure. Through cross-comparison of S11 and S21 at corresponding positions across three phases, sensor aging or failure can be effectively identified, enabling rapid on-site verification without removing the sensors. The proposed method was successfully validated on actual GIS equipment at the China Southern Power Grid Research Institute. It exhibits high accuracy, efficiency, and strong engineering applicability, enabling the early detection of degraded sensors and providing valuable support for condition assessment and maintenance decision-making in GIS online monitoring systems.