HTHaiguo Tang

Haiguo Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haiguo Tang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Efficient VF-PSD Modulation Scheme for CLLC Resonant Converter Featuring Full/Half-Bridge Compatibility and Optimized Frequency Range

    by Chaofan Cui, Haiguo Tang, Linxiao Gong, Junzhong Xu, Feng Zhang, Yong Wang

    The CLLC converter is an attractive option for battery charging applications due to their bidirectional power flow and soft-switching characteristics. However, the voltage gain curve of the CLLC converter is flat in the buck region, and existing variable-frequency or phase-shift variable-frequency modulation still require a wide switching frequency range, which increases the switching and core losses. To address this issue, a variable frequency - phase shift – duty cycle (VF-PSD) modulation is proposed in this paper. The proposed modulation features narrow frequency range, full ZVS range, and lower RMS current by introducing asymmetric duty cycle control. Notably, when voltage gain M≤0.5, the system automatically switches to half-bridge mode, further decreasing switching loss and conduction loss. A multi-harmonic model is employed to indirectly analyze the time domain characteristics of the CLLC converter under VF-PSD. Then, the optimal combinations of modulation variables are obtained through an offline particle swarm optimization (PSO) algorithm. Finally, the advantages of VF-PSD modulation are verified through a 1-kW CLLC converter experimental prototype.

  • An Improved DPWM Method Featuring Minimized-Switching-Losses and Reduced-Common-Mode-Voltage in 3L-NPC Converters Over Full Power Factor Range

    by Xing Fang, Haiguo Tang, Lingchao Kong, Linxiao Gong, Weidong Qie, Feng Zhang, Junzhong Xu, Yong Wang

    Modulation strategies of three-level neutral-point-clamped (3L-NPC) converters to suppress switching losses and common-mode (CM) voltage have gained widespread attention. However, existing methods primarily focus on unit power factor (PF) conditions, leading to optimization failure over a wide PF operating range. To address this limitation, this paper proposes a novel discontinuous pulse width modulation (DPWM) strategy that effectively minimizes both switching losses and CM voltage over the full range of leading and lagging PF angles. For switching loss reduction, a new region division method is introduced based on current magnitude boundaries and the modulation index. For peak-to-peak CM-voltage reduction, an optimal combination of clamping phases and voltage levels is analytically derived and systematically analyzed, restricting the peak-to-peak CM voltage to Udc/3 for all PF conditions. Furthermore, a simplified zero-sequence injection flowchart is developed to facilitate the rapid real-time implementation of the algorithm. Comprehensive performance evaluations, including switching losses, CM voltage characteristics, and neutral point NP voltage self-balancing capability, demonstrate the superiority of the proposed method over traditional PWM methods. Finally, simulation and experimental results validate the accuracy and effectiveness of the proposed method.

  • Effect of Zero-Sequence Control on Neutral-Point Voltage Balancing in Three-Level Grid-Forming Converters

    by Lingchao Kong, Chao Wu, Haiguo Tang, Da Xie, Yong Wang

    Most studies on grid-forming (GFM) converters have focused on two-level topologies, whereas three-level converters are more prevalent in industrial applications. Compared to two-level structures, three-level converters require additional neutral-point (NP) voltage balancing control. The strong coupling between the nonlinear dynamics of the NP voltage and the GFM control loops presents a critical challenge in the study of three-level GFM converters. Specifically: 1) The inherent NP voltage imbalance in three-level topologies leads to output voltage distortion, degrading the grid-support capability of GFM converters. 2) The closed-loop voltage regulation in GFM control further exacerbates the voltage distortion caused by NP imbalance, creating an unstable feedback loop. To address this challenge, this paper develops a linearized model of a three-level GFM converter that comprehensively integrates the GFM control loops and NP voltage dynamics. Based on this model, theoretical analysis reveals that the zero-sequence control in the GFM control loop is the decisive factor influencing NP voltage balance. Building on this insight, a novel decoupling control strategy is proposed to effectively eliminate the coupling between zero-sequence control and NP voltage dynamics. The proposed method demonstrates robust NP voltage balancing performance under various conditions. Finally, experimental results validate the accuracy of the theoretical model and the effectiveness of the proposed control scheme.


  • Open Access

    Stability Analysis of DC Microgrids Under Distributed Control Considering Converter Dynamics

    by Kehui Zhou, Haiguo Tang, Xiaochao Hou, Yi Zhang, Wenhui Mo, Zhangjie Liu

    DC microgrids (DCMGs) have attracted increasing attention owing to their high efficiency and compatibility with renewable energy sources. However, maintaining system stability under distributed control remains challenging, as the coupling between controller and converter dynamics leads to a high-order system, particularly when numerous converters are involved. For such high-order systems, singular perturbation theory can decouple the dynamics into fast and slow subsystems, allowing the overall stability to be inferred when the fast subsystem responds sufficiently faster than the slow one. Nevertheless, existing studies have not quantified how much faster the converter dynamics must be relative to the controller dynamics to ensure overall stability, which may lead to the failure of stabilization control. Moreover, when system parameters are uncertain—such as under varying load conditions—traditional stability analysis methods face difficulties in deriving explicit analytical criteria. To address these issues, this paper presents a comprehensive stability analysis of DC microgrids based on singular perturbation theory and the small-gain theorem. First, singular perturbation theory is employed to decompose the high-order DCMG into a boundary-layer subsystem and a reduced-order subsystem, and explicit analytical stability conditions are derived for each. Second, based on the small-gain theorem, it is rigorously proven that when both subsystems are stable, smaller filter capacitances, inductances, and controller gain coefficients enhance the system’s stability—and a quantitative analytical criterion is further derived to quantify this relationship. Third, under uncertain load conditions, the singular value inequality is utilized to derive analytical conditions for robust stability. Simulation results show that the relative error between the stability bound derived by the proposed conditions and the actual stability bound is about 15.4% for constant loads, and approximately 44.4% for uncertain loads—verifying the proposed method’s low-conservatism advantage under constant loads and effective robustness under uncertain loads.

  • An Online Safe-Fast Start-Up Strategy for LC -DAB Converter Based on Resonant-Voltage-Limitation

    by Lingfeng Jiang, Minqian Wang, Haiguo Tang, Yuxuan Li, Linxiao Gong, Junzhong Xu, Yong Wang

    Unlike L-DAB converters, where startup safety primarily focuses on limiting peak inductor current, LC-DAB converters require additional attention due to the overvoltage issue of resonant capacitors, causing immediate dielectric breakdown and permanent damage. Therefore, limiting the peak resonant voltage should be prioritized as a critical condition for ensuring safe startup in LC-DAB converters, which has not yet been effectively solved. To address this issue, a closed-loop safe-fast startup strategy for LC-DAB converters is proposed in this article. By keeping the peak voltage of the resonant capacitor (vrmax) to its allowable maximum during the startup process, the proposed strategy ensures converter safety while maximizing output power, thereby accelerating the startup process. First, a time-domain model of the LC-DAB converter is established through state plane trajectory analysis. Based on this model, the optimal phase shift combination that limits vrmax while maximizing output power is derived. Furthermore, smooth variation of the phase-shift angles and online optimization over a wide voltage and load range can be realized based on real-time sampling of the input and output voltages for the proposed strategy, demonstrating strong engineering applicability. Experimental results show that, compared to conventional startup strategies for LC-DAB converters, the proposed method reduces startup time by up to 73.85% under safe resonant voltage limitation.

  • Transient Inrush Current Analysis and Suppression for Grid-Forming Converters Under Grid Faults

    by Zhenzhen Xie, Tong Zhao, Haiguo Tang, Linxiao Gong, Yongzihao Dai, Chao Wu, Yong Wang, Frede Blaabjerg

    Grid-forming (GFM) converters have emerged as essential technologies for ensuring the stability of power systems dominated by renewable energy sources. Nevertheless, their restricted overcurrent capacity may trigger protection during grid faults. While existing studies emphasize the design and optimization of overcurrent mitigation strategies, precise characterization of fault current and dynamic analysis of transient inrush current are still lacking, leading to occurrences of protection malfunction. To bridge this research gap, this article considers the impact of filter parameters and current loop parameters on the equivalent impedance of the converter, and on this basis, establishes a precise fault current characterization model for GFM converters. Based on the model, the key factors influencing inrush current can be analyzed, including voltage amplitude, impedance magnitude, and power angle. Finally, a precise virtual impedance-based inrush current suppression method is proposed, which effectively limits the inrush current to the desired level while ensuring system stability. Both theoretical analysis and experimental results are carried out to validate the robustness and adaptability of the proposed strategy under various grid strengths and grid voltage sags.