Hirohito Yamazaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hirohito Yamazaki has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Keizo Ishii
Cyclotron and Radioisotope Center, Tohoku University, Sendai 980-8578, Japan
11 shared publications - Shigeo Matsuyama
Department of Quantum Science and Energy Engineering, Tohoku University, Sendai, Japan
10 shared publications - Atsuki Terakawa
Cyclotron and Radioisotope Center, Tohoku University, Sendai 980-8578, Japan
6 shared publications - Yoshinori Miura
Center for Advanced Instrumental Analysis, Kyushu University, Kasuga, Japan
5 shared publications K. Sera
Cyclotron Research Center, Iwate Medical University, Tomegamori, Takizawa 020-0173, Japan
4 shared publicationsM. Fujiwara
Department of Quantum Science and Energy Engineering, Tohoku University, Aramaki-Aza-Aoba 6-6-01-2, Aoba-ku, Sendai 980-8579, Japan
4 shared publications
Latest Publications
- Open Access
- 25 March 2021
- Published by Physical Society of Japan
- Vol. 4
Measurement of Radioactivity Produced in Concrete at the J-PARC Accelerator Tunnel
- 25 March 2021
- Published by Physical Society of Japan
- Vol. 4
Open AccessMeasurement of Radioactivity Produced in Concrete at the J-PARC Accelerator Tunnel
- Open Access
- 23 May 2016
- Published by Physical Society of Japan
The Performance Study of an Electro-Magnetic Calorimeter for the LEPS2/BGOegg Experiment
- 23 May 2016
- Published by Physical Society of Japan
Open AccessThe Performance Study of an Electro-Magnetic Calorimeter for the LEPS2/BGOegg Experiment
- 1 January 2014
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 24 (01n02) , 41-47
Concentration of cisplatin-incorporated polymeric micelles in a murine solid tumor evaluated using PIXE analysis
We report an elemental analysis of murine solid tumors treated with cisplatin-incorporated polymeric micelles (NC-6004) to evaluate the concentration of the drug in the tumor tissue using conventional particle-induced X-ray emission (PIXE) analysis, as well as the spatial distribution in the tumor section using sub-millimeter PIXE analysis. The results reveal that the platinum concentration in the tumor treated with NC-6004 was higher than in that treated with cisplatin, whereas no significant difference was found in platinum concentration between NC-6004 and cisplatin samples in the normal tissue. This suggests that NC-6004 can both provide therapeutic efficacy and reduce the side effects caused by conventional treatment using cisplatin. These results show that PIXE analysis is a powerful tool for research into drug delivery systems.
- 1 January 2014
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 24 (01n02) , 41-47
Concentration of cisplatin-incorporated polymeric micelles in a murine solid tumor evaluated using PIXE analysis
We report an elemental analysis of murine solid tumors treated with cisplatin-incorporated polymeric micelles (NC-6004) to evaluate the concentration of the drug in the tumor tissue using conventional particle-induced X-ray emission (PIXE) analysis, as well as the spatial distribution in the tumor section using sub-millimeter PIXE analysis. The results reveal that the platinum concentration in the tumor treated with NC-6004 was higher than in that treated with cisplatin, whereas no significant difference was found in platinum concentration between NC-6004 and cisplatin samples in the normal tissue. This suggests that NC-6004 can both provide therapeutic efficacy and reduce the side effects caused by conventional treatment using cisplatin. These results show that PIXE analysis is a powerful tool for research into drug delivery systems.
- 1 January 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 22 (01n02) , 101-106
ANALYSIS OF TRACE ELEMENTS IN PRE- AND POST-NATAL TOOTH ENAMEL USING MICRO-PIXE
Naturally shed deciduous teeth are potentially useful as a biomarker of environmental exposure. To assess the prenatal environment of child, we tried to present the neonatal line on the elemental maps and investigate the trace elements in pre- and post-natally formed tooth enamel using micro-PIXE. Generally, the neonatal line is observed more clearly in the tooth from child who has some difficulties at birth. In this study, five deciduous teeth from five children with developmental disorders were used for analysis. Seven trace elements ( Na , Mg , Si , Cl , Fe , Zn , and Sr ) were detected in enamel of all five teeth. The line, it was thought neonatal line, was observed on the elemental map of Ca and P in the tooth from the child with serious birth complications. In order to compare the elemental concentration between pre- and post-natal enamel, concentration variation of elements were projected along the line perpendicular to the neonatal line. Lower Ca concentration in prenatal enamel was observed. By tracing the location of neonatal line on the other elemental maps, the concentrations of detected trace elements were compared in the same way. The differences of concentration of these trace elements between pre- and post-natal enamel were not clear because of much statistic variation. We could determine the trace elemental profiles and concentrations around the neonatal line in the enamel from the child with serious birth complications.
- 1 January 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 22 (01n02) , 101-106
ANALYSIS OF TRACE ELEMENTS IN PRE- AND POST-NATAL TOOTH ENAMEL USING MICRO-PIXE
Naturally shed deciduous teeth are potentially useful as a biomarker of environmental exposure. To assess the prenatal environment of child, we tried to present the neonatal line on the elemental maps and investigate the trace elements in pre- and post-natally formed tooth enamel using micro-PIXE. Generally, the neonatal line is observed more clearly in the tooth from child who has some difficulties at birth. In this study, five deciduous teeth from five children with developmental disorders were used for analysis. Seven trace elements ( Na , Mg , Si , Cl , Fe , Zn , and Sr ) were detected in enamel of all five teeth. The line, it was thought neonatal line, was observed on the elemental map of Ca and P in the tooth from the child with serious birth complications. In order to compare the elemental concentration between pre- and post-natal enamel, concentration variation of elements were projected along the line perpendicular to the neonatal line. Lower Ca concentration in prenatal enamel was observed. By tracing the location of neonatal line on the other elemental maps, the concentrations of detected trace elements were compared in the same way. The differences of concentration of these trace elements between pre- and post-natal enamel were not clear because of much statistic variation. We could determine the trace elemental profiles and concentrations around the neonatal line in the enamel from the child with serious birth complications.
- 1 January 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 22 (01n02) , 45-50
PIXE ANALYSIS OF DYES USED IN TRADITIONAL JAPANESE CARPETS (NABESHIMA-DANTSU)
NABESHIMA-DANTSU is the name of the first Japanese-made carpets which have been produced in the Nabeshima domain (Saga Prefecture) since the later Edo period. The NABESHIMA-DANTSU carpets have been woven from one kind of cotton, and have been dyed with various dyes and color fixatives. We analyzed pieces of the NABESHIMA-DANTSU carpets stored in the Saga Prefectural Museum and the Saga Prefectural Art Museum, by using PIXE method in order to detect dyeing methods used in them. We also analyzed dyes, color fixatives and cotton used in the traditional Japanese dyeing method. From the NABESHIMA-DANTSU carpets, small amounts of dyed and non-dyed samples were picked up and were analyzed by in-air PIXE system at Tohoku University. It was found that Fe and Cu are related to the parts dyed orange, and Al is related to the parts dyed green. The analysis of cotton dyed by the traditional Japanese method shows the similar results. It means that both colors in the NABESHIMA-DANTSU carpets were dyed by the traditional Japanese method which uses natural dyes. From literature documentation, it is considered that synthetic dyes were mainly used during the Taisho era. The present result shows that natural dyes might have been used in the Taisho era. In this research the PIXE method has proved to be very effective for the analysis of dyeing methods.
- 1 January 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 22 (01n02) , 45-50
PIXE ANALYSIS OF DYES USED IN TRADITIONAL JAPANESE CARPETS (NABESHIMA-DANTSU)
NABESHIMA-DANTSU is the name of the first Japanese-made carpets which have been produced in the Nabeshima domain (Saga Prefecture) since the later Edo period. The NABESHIMA-DANTSU carpets have been woven from one kind of cotton, and have been dyed with various dyes and color fixatives. We analyzed pieces of the NABESHIMA-DANTSU carpets stored in the Saga Prefectural Museum and the Saga Prefectural Art Museum, by using PIXE method in order to detect dyeing methods used in them. We also analyzed dyes, color fixatives and cotton used in the traditional Japanese dyeing method. From the NABESHIMA-DANTSU carpets, small amounts of dyed and non-dyed samples were picked up and were analyzed by in-air PIXE system at Tohoku University. It was found that Fe and Cu are related to the parts dyed orange, and Al is related to the parts dyed green. The analysis of cotton dyed by the traditional Japanese method shows the similar results. It means that both colors in the NABESHIMA-DANTSU carpets were dyed by the traditional Japanese method which uses natural dyes. From literature documentation, it is considered that synthetic dyes were mainly used during the Taisho era. The present result shows that natural dyes might have been used in the Taisho era. In this research the PIXE method has proved to be very effective for the analysis of dyeing methods.
- 1 January 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 22 (01n02) , 37-43
IMPROVEMENT OF THE DETECTION EFFICIENCY OF THE IN-AIR SUBMILLI-PIXE CAMERA FOR BIOLOGICAL APPLICATIONS
The detection efficiency of the submilli-PIXE camera was improved by installing a new X-ray detector with a smaller distance from specimens. The distortion of elemental images caused by position dependent detection efficiency was corrected by estimating the detection efficiency based on the geometrical configuration of the detection system. The detection efficiency of characteristic X-rays from heavy elements such as iron and bromine became from 11 to 23 times higher than the previous system. The signal to noise ratios was improved from 1.8 to 2.5 times higher and detection limit was also decreased from 1/8 to 1/6 compared to the previous system. The in-air submilli-PIXE camera with improved detection system can be useful to biological applications.
- 1 January 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 22 (01n02) , 37-43
IMPROVEMENT OF THE DETECTION EFFICIENCY OF THE IN-AIR SUBMILLI-PIXE CAMERA FOR BIOLOGICAL APPLICATIONS
The detection efficiency of the submilli-PIXE camera was improved by installing a new X-ray detector with a smaller distance from specimens. The distortion of elemental images caused by position dependent detection efficiency was corrected by estimating the detection efficiency based on the geometrical configuration of the detection system. The detection efficiency of characteristic X-rays from heavy elements such as iron and bromine became from 11 to 23 times higher than the previous system. The signal to noise ratios was improved from 1.8 to 2.5 times higher and detection limit was also decreased from 1/8 to 1/6 compared to the previous system. The in-air submilli-PIXE camera with improved detection system can be useful to biological applications.
- 1 January 2011
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 21 (03n04) , 125-131
PIXE ANALYSIS OF A MURINE FIBROSARCOMA TUMOR TREATED WITH A VASCULAR DISRUPTING AGENT AVE8062
Spatial distributions of principal elements in a NFSa fibrosarcoma tumor treated with a vascular disruption agent, AVE8062 (a derivative of combretastatin A-4) at a single dose of 40 mg/kg were evaluated on the basis of particle-induced X-ray emission (PIXE) analysis using a submillimeter-sized proton beam. We found not only potassium and sulfur concentrations at the periphery of the treated tumor but also a ring-shaped calcium distribution in the area between the inner necrotic region and the periphery. These observations were supported by results for quantitative evaluation of elemental concentrations in the tumor samples obtained from conventional PIXE analysis based on the internal standard method. It is suggested that the potassium and sulfur concentrations are related to residual viable cells at the tumor periphery which are commonly observed in VDA treatments whereas the ring of calcium concentration just inside the tumor periphery is possibly derived from hypoxia-induced response.
- 1 January 2011
- Published by World Scientific Pub Co Pte Ltd in International Journal of PIXE
- Vol. 21 (03n04) , 125-131
PIXE ANALYSIS OF A MURINE FIBROSARCOMA TUMOR TREATED WITH A VASCULAR DISRUPTING AGENT AVE8062
Spatial distributions of principal elements in a NFSa fibrosarcoma tumor treated with a vascular disruption agent, AVE8062 (a derivative of combretastatin A-4) at a single dose of 40 mg/kg were evaluated on the basis of particle-induced X-ray emission (PIXE) analysis using a submillimeter-sized proton beam. We found not only potassium and sulfur concentrations at the periphery of the treated tumor but also a ring-shaped calcium distribution in the area between the inner necrotic region and the periphery. These observations were supported by results for quantitative evaluation of elemental concentrations in the tumor samples obtained from conventional PIXE analysis based on the internal standard method. It is suggested that the potassium and sulfur concentrations are related to residual viable cells at the tumor periphery which are commonly observed in VDA treatments whereas the ring of calcium concentration just inside the tumor periphery is possibly derived from hypoxia-induced response.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 3709-3710
Prototype of TlBr detector array for ultra high resolution PET
We developed a prototype of TlBr semiconductor detector array for high resolution PET scanner with less than 1mm FWHM. We obtained an energy resolution of ∼20% FWHM for 511 keV and a coincidence time resolution of ∼50nsec FWHM at a detector bias 100V. This result expects the capability of application of TlBr detector array to a high resolution PET scanner. The TlBr detector arrays with the present time resolution performance can be applied to a small PET scanner for the PET study using small animals such as rats and mice.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 3709-3710
Prototype of TlBr detector array for ultra high resolution PET
We developed a prototype of TlBr semiconductor detector array for high resolution PET scanner with less than 1mm FWHM. We obtained an energy resolution of ∼20% FWHM for 511 keV and a coincidence time resolution of ∼50nsec FWHM at a detector bias 100V. This result expects the capability of application of TlBr detector array to a high resolution PET scanner. The TlBr detector arrays with the present time resolution performance can be applied to a small PET scanner for the PET study using small animals such as rats and mice.
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 1589-1592
FDG imaging of 1mm tumor with an ultra high resolution animal PET
Recently, we reported an animal semiconductor PET with the spatial resolution of 0.8 mm FWHM within the central 20 mm-diameter of FOV for the purpose of biomedical study using rats and mice. This ultra high spatial resolution was obtained by the use of small CdTe elements of 1.1mm x 1.0 mm x 5 mm. The FOV of this PET is 64 mm in diameter and 26 mm in axis. We applied to observe small tumors in mouse and succeeded to 1 Q obtain [ F]FDG images of mouse mammary carcinoma of ~1mm size.
- 1 May 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457928,p. 1589-1592
FDG imaging of 1mm tumor with an ultra high resolution animal PET
Recently, we reported an animal semiconductor PET with the spatial resolution of 0.8 mm FWHM within the central 20 mm-diameter of FOV for the purpose of biomedical study using rats and mice. This ultra high spatial resolution was obtained by the use of small CdTe elements of 1.1mm x 1.0 mm x 5 mm. The FOV of this PET is 64 mm in diameter and 26 mm in axis. We applied to observe small tumors in mouse and succeeded to 1 Q obtain [ F]FDG images of mouse mammary carcinoma of ~1mm size.