Kazuhiko Oyu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kazuhiko Oyu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Nozaki
GE Healthcare, Hino, Japan
1 shared publication - Fumiyasu Tsushima
Department of Radiology, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
1 shared publication - Kana Saito
Department of Radiology, Hirosaki University Graduate School of Medicine, Hirosaki 036-8562, Japan
1 shared publication - Keita Watanabe
Department of Radiology, Kyoto Prefectural University of Medicine, Kyoto, Japan
1 shared publication - Sera Kasai
Department of Radiology, Hirosaki University, Hirosaki, Japan
1 shared publication Shingo Kakeda
Department of Radiology, Hirosaki University School of Medicine, Hirosaki, Japan
1 shared publication
Latest Publications
- 24 August 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1623-1635
Agreement and reproducibility of quantitative values depend on acquisition parameters in magnetic resonance fingerprinting
This study evaluated the effects of acquisition parameters on relaxation times measured using magnetic resonance fingerprinting (MRF). MRF enables the simultaneous acquisition of multiple quantitative maps by varying the flip angle (FA) and repetition time (TR) in a pseudo-random manner and by pattern-matching signal evolutions to a pre-calculated dictionary. To assess parameter dependency, multiple acquisition protocols were generated with varying numbers of echoes (500, 1000, 1500, and 3000), TR widths (12–14 ms, 12–17 ms, and 12–20 ms), and maximum FA ranges using the MRF Development Kit. The International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology system phantom was scanned ten times per condition on a 3-Tesla scanner. Coefficients of variation (CVs) and agreement were calculated for T1 and T2 values. Results indicated that 1500 and 3000 echoes produced comparable agreement and reproducibility (agreement within ± 7.77% and CVs ≤ 1.13% for both T1 and T2). At 500 echoes, CVs increased substantially and agreement decreased, with T2 values being more affected than T1 values. At 1000 echoes with an expanded TR width (12–20 ms), CVs were 1.15% or less and agreement was within ± 5.20%, comparable to higher echo counts while reducing scan time by approximately 20%. This study demonstrated that the number of echoes, TR width, and maximum FA significantly influence T1 and T2 agreement and reproducibility, suggesting that expanding the TR range can stabilize relaxation times even with fewer echoes.
- 24 August 2026
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1623-1635
Agreement and reproducibility of quantitative values depend on acquisition parameters in magnetic resonance fingerprinting
This study evaluated the effects of acquisition parameters on relaxation times measured using magnetic resonance fingerprinting (MRF). MRF enables the simultaneous acquisition of multiple quantitative maps by varying the flip angle (FA) and repetition time (TR) in a pseudo-random manner and by pattern-matching signal evolutions to a pre-calculated dictionary. To assess parameter dependency, multiple acquisition protocols were generated with varying numbers of echoes (500, 1000, 1500, and 3000), TR widths (12–14 ms, 12–17 ms, and 12–20 ms), and maximum FA ranges using the MRF Development Kit. The International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology system phantom was scanned ten times per condition on a 3-Tesla scanner. Coefficients of variation (CVs) and agreement were calculated for T1 and T2 values. Results indicated that 1500 and 3000 echoes produced comparable agreement and reproducibility (agreement within ± 7.77% and CVs ≤ 1.13% for both T1 and T2). At 500 echoes, CVs increased substantially and agreement decreased, with T2 values being more affected than T1 values. At 1000 echoes with an expanded TR width (12–20 ms), CVs were 1.15% or less and agreement was within ± 5.20%, comparable to higher echo counts while reducing scan time by approximately 20%. This study demonstrated that the number of echoes, TR width, and maximum FA significantly influence T1 and T2 agreement and reproducibility, suggesting that expanding the TR range can stabilize relaxation times even with fewer echoes.
- 22 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1377-1385
Deep-learning reconstruction enables about one minute 3D T1-weighted MRI: quantitative evaluation of Acceleration-quality Trade-offs and motion reduction
Purpose Deep learning-based reconstruction techniques, such as the prototype DL-Speed, have been developed to accelerate 3D T1-weighted imaging, but their clinical utility and impact on quantitative analysis have not been systematically validated. The purpose of this study is to evaluate the utility of a deep learning-based reconstruction method for substantially accelerating image acquisition without compromising quantitative image quality and morphometry. Methods Six healthy volunteers were scanned with 3D MPRAGE using acceleration factors ranging from 2 to 16. Image quality was assessed using the CAT12 Image Quality Rating (IQR), and morphometry with CAT12 global cortical thickness and total gray matter (GM) volume. In a clinical cohort of 40 patients, DL-Speed with 11-fold acceleration (1 min 10 s) was compared to conventional imaging (4 min 59 s). Head motion was quantified via total vector change (TVC) using volumetric navigators. Results In healthy volunteers, image quality remained within CAT12 Rank A at all acceleration levels; IQR followed a quadratic trend (R² = 0.98). Global cortical thickness decreased approximately linearly with acceleration (e.g., DLS2→DLS11: −0.068 mm [− 2.8%]; DLS2→DLS16: −0.140 mm [− 5.7%]). Total GM volume showed a shallow, monotonic decline (group means: 748.8 mL at DLS2 → 729.5 mL at DLS11 [− 2.6%] → 726.3 mL at DLS16 [− 3.0%]). In clinical cohort, DL-Speed significantly reduced head motion (TVC: 52.3 ± 9.4 mm vs. 140.4 ± 32.8 mm, p < 0.001) while maintaining acceptable image quality (IQR: 93.9 ± 1.0% vs. 94.8 ± 1.2%, p < 0.001). Bland–Altman analysis showed narrow limits of agreement (–2.49% to + 0.75%). Regarding cortical thickness and GM volume, we found significant correlations between conventional images and DL-Speed (thickness r = 0.97; GM r = 0.99; both p < 0.001). Conclusion DL-Speed enables about-one-minute 3D T1-weighted imaging that markedly reduces motion while preserving quantitative image integrity suitable for morphometry. Because image quality (IQR) follows a non-linear (quadratic) dependency whereas cortical thickness and GM volume decline nearly linearly, the data support a practical operating range (e.g., 6–11-fold acceleration) rather than a single optimal factor. Trial registration Not applicable.
- 22 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1377-1385
Deep-learning reconstruction enables about one minute 3D T1-weighted MRI: quantitative evaluation of Acceleration-quality Trade-offs and motion reduction
Purpose Deep learning-based reconstruction techniques, such as the prototype DL-Speed, have been developed to accelerate 3D T1-weighted imaging, but their clinical utility and impact on quantitative analysis have not been systematically validated. The purpose of this study is to evaluate the utility of a deep learning-based reconstruction method for substantially accelerating image acquisition without compromising quantitative image quality and morphometry. Methods Six healthy volunteers were scanned with 3D MPRAGE using acceleration factors ranging from 2 to 16. Image quality was assessed using the CAT12 Image Quality Rating (IQR), and morphometry with CAT12 global cortical thickness and total gray matter (GM) volume. In a clinical cohort of 40 patients, DL-Speed with 11-fold acceleration (1 min 10 s) was compared to conventional imaging (4 min 59 s). Head motion was quantified via total vector change (TVC) using volumetric navigators. Results In healthy volunteers, image quality remained within CAT12 Rank A at all acceleration levels; IQR followed a quadratic trend (R² = 0.98). Global cortical thickness decreased approximately linearly with acceleration (e.g., DLS2→DLS11: −0.068 mm [− 2.8%]; DLS2→DLS16: −0.140 mm [− 5.7%]). Total GM volume showed a shallow, monotonic decline (group means: 748.8 mL at DLS2 → 729.5 mL at DLS11 [− 2.6%] → 726.3 mL at DLS16 [− 3.0%]). In clinical cohort, DL-Speed significantly reduced head motion (TVC: 52.3 ± 9.4 mm vs. 140.4 ± 32.8 mm, p < 0.001) while maintaining acceptable image quality (IQR: 93.9 ± 1.0% vs. 94.8 ± 1.2%, p < 0.001). Bland–Altman analysis showed narrow limits of agreement (–2.49% to + 0.75%). Regarding cortical thickness and GM volume, we found significant correlations between conventional images and DL-Speed (thickness r = 0.97; GM r = 0.99; both p < 0.001). Conclusion DL-Speed enables about-one-minute 3D T1-weighted imaging that markedly reduces motion while preserving quantitative image integrity suitable for morphometry. Because image quality (IQR) follows a non-linear (quadratic) dependency whereas cortical thickness and GM volume decline nearly linearly, the data support a practical operating range (e.g., 6–11-fold acceleration) rather than a single optimal factor. Trial registration Not applicable.