Agreement and reproducibility of quantitative values depend on acquisition parameters in magnetic resonance fingerprinting
Authors:
- 24 August 2026
- journal article
- research article
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 19 (4) , 1623-1635
Abstract
This study evaluated the effects of acquisition parameters on relaxation times measured using magnetic resonance fingerprinting (MRF). MRF enables the simultaneous acquisition of multiple quantitative maps by varying the flip angle (FA) and repetition time (TR) in a pseudo-random manner and by pattern-matching signal evolutions to a pre-calculated dictionary. To assess parameter dependency, multiple acquisition protocols were generated with varying numbers of echoes (500, 1000, 1500, and 3000), TR widths (12–14 ms, 12–17 ms, and 12–20 ms), and maximum FA ranges using the MRF Development Kit. The International Society for Magnetic Resonance in Medicine/National Institute of Standards and Technology system phantom was scanned ten times per condition on a 3-Tesla scanner. Coefficients of variation (CVs) and agreement were calculated for T1 and T2 values. Results indicated that 1500 and 3000 echoes produced comparable agreement and reproducibility (agreement within ± 7.77% and CVs ≤ 1.13% for both T1 and T2). At 500 echoes, CVs increased substantially and agreement decreased, with T2 values being more affected than T1 values. At 1000 echoes with an expanded TR width (12–20 ms), CVs were 1.15% or less and agreement was within ± 5.20%, comparable to higher echo counts while reducing scan time by approximately 20%. This study demonstrated that the number of echoes, TR width, and maximum FA significantly influence T1 and T2 agreement and reproducibility, suggesting that expanding the TR range can stabilize relaxation times even with fewer echoes.Keywords
This publication has 26 references indexed in Scilit:
- DTI‐MR fingerprinting for rapid high‐resolution whole‐brain T1, T2, proton density, ADC, and fractional anisotropy mappingMagnetic Resonance in Medicine, 2023
- CEST MR fingerprinting (CEST‐MRF) for brain tumor quantification using EPI readout and deep learning reconstructionMagnetic Resonance in Medicine, 2022
- Quantitative T1 mapping indicates tumor infiltration beyond the enhancing part of glioblastomasNMR in Biomedicine, 2019
- Rigid motion‐corrected magnetic resonance fingerprintingMagnetic Resonance in Medicine, 2018
- MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readoutMagnetic Resonance in Medicine, 2014
- Assessment of therapeutic response and treatment planning for brain tumors using metabolic and physiological MRINMR in Biomedicine, 2011
- Neuro MR: PrinciplesJournal of Magnetic Resonance Imaging, 2007
- Routine clinical brain MRI sequences for use at 3.0 TeslaJournal of Magnetic Resonance Imaging, 2005
- Methods of measuring spin-lattice (T1) relaxation times: An annotated bibliographyConcepts in Magnetic Resonance, 1999
- NMR relaxation times in the human brain at 3.0 teslaJournal of Magnetic Resonance Imaging, 1999