Shinya Kakehata
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shinya Kakehata has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Nozaki
GE Healthcare, Hino, Japan
1 shared publication - Beng Gwan Teh
Department of Oral and Maxillofacial Surgery, Graduate School of Medicine, Hirosaki University, 5-Zaifuchou, Hirosaki 036-8563, Japan
1 shared publication - Fumiyasu Tsushima
Department of Radiology, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
1 shared publication - Kana Saito
Department of Radiology, Hirosaki University Graduate School of Medicine, Hirosaki 036-8562, Japan
1 shared publication - Kazuhiko Oyu
Division of Radiology, Hirosaki University Hospital, Hirosaki, Japan
1 shared publication - Keita Watanabe
Department of Radiology, Kyoto Prefectural University of Medicine, Kyoto, Japan
1 shared publication
Latest Publications
- Open Access
Should Super-Selective Intra-Arterial Chemoradiotherapy Be Prioritized over Surgical Resection for Locally Advanced Oral Cavity Cancer?
Background/Objectives: Super-selective intra-arterial chemoradiotherapy (SSIACRT) is an alternatively effective treatment for locally advanced oral cavity cancer although no comparative studies on prognosis between SSIACRT and surgical resection with or without post-operative radiotherapy (S+R) have been reported. This study aimed to compare the 5-year survival rate and Quality of Life (QoL) between S+R and SSIACRT for locally advanced oral cavity cancer. Methods: From a total of 326 patients with stage III and IV oral cavity cancer treated between 2000–2020 at a single institution, 149 patients treated with S+R and SSIACRT were analyzed by using Propensity Score Matching (PSM) method, a pseudo-randomized controlled trial, and the matched cases were retrospectively evaluated. The 5-year survival rate and QoL were evaluated using the Kaplan–Meier method and the University of Washington QoL questionnaire, respectively. Log-rank test and Cox proportional hazards model were used to compare 5-year survival rate and to assess factors affecting survival rates, respectively. Paired t-test was used to compare QoL. Results: To compare the 5-year survival rate and QoL between S+R and SSIACRT, 48 and 15 cases were matched after PSM. The 149 cases were further evaluated for covariates affecting survival rates. The 5-year disease-specific survival rate and 5-year crude survival rate were 52.4% and 44.3% for S+R and 71.3%, and 62.9% for SSIACRT, respectively. There was no statistical difference in survival rates between both treatments, based on Log-rank test analysis. Treatment method was the only independent variable that influenced survival rates. SSIACRT showed better statistical difference in QoL evaluation, specifically in appearance, activity, recreation, swallowing, speech, shoulder, taste, mood, and total score. Conclusions: Propensity score-matched analysis demonstrated survival outcomes that were comparable to, and not inferior to, S+R. However, SSIACRT was associated with superior quality-of-life outcomes compared with S+R, as shown by Cox proportional hazards modeling. These findings suggest that SSIACRT is an effective treatment option and, from a quality-of-life perspective, may be considered a preferable approach in the management of locally advanced oral cavity cancer.
Open AccessShould Super-Selective Intra-Arterial Chemoradiotherapy Be Prioritized over Surgical Resection for Locally Advanced Oral Cavity Cancer?
Background/Objectives: Super-selective intra-arterial chemoradiotherapy (SSIACRT) is an alternatively effective treatment for locally advanced oral cavity cancer although no comparative studies on prognosis between SSIACRT and surgical resection with or without post-operative radiotherapy (S+R) have been reported. This study aimed to compare the 5-year survival rate and Quality of Life (QoL) between S+R and SSIACRT for locally advanced oral cavity cancer. Methods: From a total of 326 patients with stage III and IV oral cavity cancer treated between 2000–2020 at a single institution, 149 patients treated with S+R and SSIACRT were analyzed by using Propensity Score Matching (PSM) method, a pseudo-randomized controlled trial, and the matched cases were retrospectively evaluated. The 5-year survival rate and QoL were evaluated using the Kaplan–Meier method and the University of Washington QoL questionnaire, respectively. Log-rank test and Cox proportional hazards model were used to compare 5-year survival rate and to assess factors affecting survival rates, respectively. Paired t-test was used to compare QoL. Results: To compare the 5-year survival rate and QoL between S+R and SSIACRT, 48 and 15 cases were matched after PSM. The 149 cases were further evaluated for covariates affecting survival rates. The 5-year disease-specific survival rate and 5-year crude survival rate were 52.4% and 44.3% for S+R and 71.3%, and 62.9% for SSIACRT, respectively. There was no statistical difference in survival rates between both treatments, based on Log-rank test analysis. Treatment method was the only independent variable that influenced survival rates. SSIACRT showed better statistical difference in QoL evaluation, specifically in appearance, activity, recreation, swallowing, speech, shoulder, taste, mood, and total score. Conclusions: Propensity score-matched analysis demonstrated survival outcomes that were comparable to, and not inferior to, S+R. However, SSIACRT was associated with superior quality-of-life outcomes compared with S+R, as shown by Cox proportional hazards modeling. These findings suggest that SSIACRT is an effective treatment option and, from a quality-of-life perspective, may be considered a preferable approach in the management of locally advanced oral cavity cancer.
- 22 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1377-1385
Deep-learning reconstruction enables about one minute 3D T1-weighted MRI: quantitative evaluation of Acceleration-quality Trade-offs and motion reduction
Purpose Deep learning-based reconstruction techniques, such as the prototype DL-Speed, have been developed to accelerate 3D T1-weighted imaging, but their clinical utility and impact on quantitative analysis have not been systematically validated. The purpose of this study is to evaluate the utility of a deep learning-based reconstruction method for substantially accelerating image acquisition without compromising quantitative image quality and morphometry. Methods Six healthy volunteers were scanned with 3D MPRAGE using acceleration factors ranging from 2 to 16. Image quality was assessed using the CAT12 Image Quality Rating (IQR), and morphometry with CAT12 global cortical thickness and total gray matter (GM) volume. In a clinical cohort of 40 patients, DL-Speed with 11-fold acceleration (1 min 10 s) was compared to conventional imaging (4 min 59 s). Head motion was quantified via total vector change (TVC) using volumetric navigators. Results In healthy volunteers, image quality remained within CAT12 Rank A at all acceleration levels; IQR followed a quadratic trend (R² = 0.98). Global cortical thickness decreased approximately linearly with acceleration (e.g., DLS2→DLS11: −0.068 mm [− 2.8%]; DLS2→DLS16: −0.140 mm [− 5.7%]). Total GM volume showed a shallow, monotonic decline (group means: 748.8 mL at DLS2 → 729.5 mL at DLS11 [− 2.6%] → 726.3 mL at DLS16 [− 3.0%]). In clinical cohort, DL-Speed significantly reduced head motion (TVC: 52.3 ± 9.4 mm vs. 140.4 ± 32.8 mm, p < 0.001) while maintaining acceptable image quality (IQR: 93.9 ± 1.0% vs. 94.8 ± 1.2%, p < 0.001). Bland–Altman analysis showed narrow limits of agreement (–2.49% to + 0.75%). Regarding cortical thickness and GM volume, we found significant correlations between conventional images and DL-Speed (thickness r = 0.97; GM r = 0.99; both p < 0.001). Conclusion DL-Speed enables about-one-minute 3D T1-weighted imaging that markedly reduces motion while preserving quantitative image integrity suitable for morphometry. Because image quality (IQR) follows a non-linear (quadratic) dependency whereas cortical thickness and GM volume decline nearly linearly, the data support a practical operating range (e.g., 6–11-fold acceleration) rather than a single optimal factor. Trial registration Not applicable.
- 22 November 2025
- Published by Springer Nature in Neuroradiology
- Vol. 68 (5) , 1377-1385
Deep-learning reconstruction enables about one minute 3D T1-weighted MRI: quantitative evaluation of Acceleration-quality Trade-offs and motion reduction
Purpose Deep learning-based reconstruction techniques, such as the prototype DL-Speed, have been developed to accelerate 3D T1-weighted imaging, but their clinical utility and impact on quantitative analysis have not been systematically validated. The purpose of this study is to evaluate the utility of a deep learning-based reconstruction method for substantially accelerating image acquisition without compromising quantitative image quality and morphometry. Methods Six healthy volunteers were scanned with 3D MPRAGE using acceleration factors ranging from 2 to 16. Image quality was assessed using the CAT12 Image Quality Rating (IQR), and morphometry with CAT12 global cortical thickness and total gray matter (GM) volume. In a clinical cohort of 40 patients, DL-Speed with 11-fold acceleration (1 min 10 s) was compared to conventional imaging (4 min 59 s). Head motion was quantified via total vector change (TVC) using volumetric navigators. Results In healthy volunteers, image quality remained within CAT12 Rank A at all acceleration levels; IQR followed a quadratic trend (R² = 0.98). Global cortical thickness decreased approximately linearly with acceleration (e.g., DLS2→DLS11: −0.068 mm [− 2.8%]; DLS2→DLS16: −0.140 mm [− 5.7%]). Total GM volume showed a shallow, monotonic decline (group means: 748.8 mL at DLS2 → 729.5 mL at DLS11 [− 2.6%] → 726.3 mL at DLS16 [− 3.0%]). In clinical cohort, DL-Speed significantly reduced head motion (TVC: 52.3 ± 9.4 mm vs. 140.4 ± 32.8 mm, p < 0.001) while maintaining acceptable image quality (IQR: 93.9 ± 1.0% vs. 94.8 ± 1.2%, p < 0.001). Bland–Altman analysis showed narrow limits of agreement (–2.49% to + 0.75%). Regarding cortical thickness and GM volume, we found significant correlations between conventional images and DL-Speed (thickness r = 0.97; GM r = 0.99; both p < 0.001). Conclusion DL-Speed enables about-one-minute 3D T1-weighted imaging that markedly reduces motion while preserving quantitative image integrity suitable for morphometry. Because image quality (IQR) follows a non-linear (quadratic) dependency whereas cortical thickness and GM volume decline nearly linearly, the data support a practical operating range (e.g., 6–11-fold acceleration) rather than a single optimal factor. Trial registration Not applicable.