Lalit Chaudhari
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lalit Chaudhari has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Vysakh Raveendran
Homi Bhabha National Institute
3 shared publications - Siddhartha Laskar
Tata Memorial Centre Department of Radiation Oncology
2 shared publications A. Chithambara Prabu
Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, 410210 India
1 shared publicationAbhijeet Ashok Powar
Department of Radiation Oncology, Advanced Centre for Treatment Research and Education in Cancer, Tata Memorial Centre, Homi Bhabha National Institute, Mumbai, Maharashtra, 410210 India
1 shared publicationAishwarya Guruvaiah
Department of Medical Physics, Apollo Proton Cancer Centre, Chennai, Tamil Nadu, India
1 shared publication- Akshay Bhavke
Homi Bhabha National Institute
1 shared publication
Latest Publications
- 1 October 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055076
Fabrication, testing, and clinical validation of an epoxy resin-based range shifter for pencil beam scanning proton therapy
Background and Objectives. Range shifters (RS) are used to treat shallow targets in pencil beam scanning (PBS) proton therapy. This study aims to validate an in-house-fabricated epoxy resin RS through mechanical and dosimetric measurements, evaluate the Monte Carlo (MC) algorithm dose‐calculation accuracy of the treatment planning system (TPS) beam model incorporating this device, and assess its clinical feasibility for PBS proton therapy applications. Methods. The RS was fabricated using a silicone mould and machined to the required dimensions after curing. It was further evaluated through material characterization, mechanical testing, and dosimetric validation. Material characterization included determining the elemental composition, mass density, and mean excitation energy, which were incorporated into the beam modelling. Mechanical validation comprised dimensional verification, fitment testing, and assessment of material integrity and uniformity. Dosimetric validation was performed by measuring water-equivalent thickness (WET), range parameters, spot size, absolute dose, and fluence, and comparing them with TPS-MC calculations. Results. The cured epoxy resin exhibited normalized elemental composition of H:8.0%, C:65.0%, N:0.1%, and O:26.9%, with mass density 1.15 g cm −3 and mean excitation energy 72.5 eV. The fabricated RS matched the reference design within ±1 mm and demonstrated satisfactory fitment, reproducibility, material integrity and uniformity. The measured WET agreed with TPS estimated values within 0.06 g cm −2 , while differences in range parameters were Conclusion. This study presents the first comprehensive clinical validation and evaluation of cured solid epoxy resin as an RS material for PBS proton therapy applications. The in-house-fabricated, cured epoxy resin-based RS demonstrated excellent agreement with TPS-MC calculations and experimental measurements, establishing its clinical feasibility.
- 1 October 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (5) , 055076
Fabrication, testing, and clinical validation of an epoxy resin-based range shifter for pencil beam scanning proton therapy
Background and Objectives. Range shifters (RS) are used to treat shallow targets in pencil beam scanning (PBS) proton therapy. This study aims to validate an in-house-fabricated epoxy resin RS through mechanical and dosimetric measurements, evaluate the Monte Carlo (MC) algorithm dose‐calculation accuracy of the treatment planning system (TPS) beam model incorporating this device, and assess its clinical feasibility for PBS proton therapy applications. Methods. The RS was fabricated using a silicone mould and machined to the required dimensions after curing. It was further evaluated through material characterization, mechanical testing, and dosimetric validation. Material characterization included determining the elemental composition, mass density, and mean excitation energy, which were incorporated into the beam modelling. Mechanical validation comprised dimensional verification, fitment testing, and assessment of material integrity and uniformity. Dosimetric validation was performed by measuring water-equivalent thickness (WET), range parameters, spot size, absolute dose, and fluence, and comparing them with TPS-MC calculations. Results. The cured epoxy resin exhibited normalized elemental composition of H:8.0%, C:65.0%, N:0.1%, and O:26.9%, with mass density 1.15 g cm −3 and mean excitation energy 72.5 eV. The fabricated RS matched the reference design within ±1 mm and demonstrated satisfactory fitment, reproducibility, material integrity and uniformity. The measured WET agreed with TPS estimated values within 0.06 g cm −2 , while differences in range parameters were Conclusion. This study presents the first comprehensive clinical validation and evaluation of cured solid epoxy resin as an RS material for PBS proton therapy applications. The in-house-fabricated, cured epoxy resin-based RS demonstrated excellent agreement with TPS-MC calculations and experimental measurements, establishing its clinical feasibility.
- Open Access
- 25 September 2026
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 22, 101966
Design, Customization, and Implementation of an Oncology Information System-Based Paperless Proton Therapy Workflow
- 25 September 2026
- Published by Elsevier in International Journal of Particle Therapy
- Vol. 22, 101966
Open AccessDesign, Customization, and Implementation of an Oncology Information System-Based Paperless Proton Therapy Workflow
- Open Access
- 21 November 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 56, 101084
Pre-PROTO-PRIME: stereotactic body proton therapy to the prostate and pelvic nodes for high-risk and node-positive prostate cancer — feasibility, acute toxicity and dosimetric insights
- 21 November 2025
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 56, 101084
Open AccessPre-PROTO-PRIME: stereotactic body proton therapy to the prostate and pelvic nodes for high-risk and node-positive prostate cancer — feasibility, acute toxicity and dosimetric insights