Hazlita Isa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hazlita Isa has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chin Fhong Soon
Faculty of Electrical and Electronics Engineering, Universiti Tun Hussein Onn Malaysia, Batu Pahat 86400, Johor, Malaysia
2 shared publications - Kian Sek Tee
Universiti Tun Hussein Onn Malaysia
2 shared publications - Wan Nurshazwani Wan Zakaria
Universiti Tun Hussein Onn Malaysia
2 shared publications Chun Zhi E
Faculty of Electrical and Electronic Engineering, Universiti Tun Hussein Onn Malaysia, Batu Pahat, Johor, Malaysia
1 shared publication- Dirman Hanafi
Universiti Tun Hussein Onn Malaysia
1 shared publication - Hashim Saim
Universiti Tun Hussein Onn Malaysia
1 shared publication
Latest Publications
- Open Access
- 1 June 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (3) , 1180-1187
Development of a 3D bio-printer using CoreXY mechanism and syringe-based extrusion
3D Bio-printer is said to have potential in the applications of medical studies and tissue engineering. A 3D Bio-printer could be used to print the artificial organs for organs transplant and cell tissue culture for generating new cell tissue. It could help in future medical and biological research. This paper presents the development process, i.e. working principle of Fused Deposition Modelling (FDM), mechanical, electrical and related applied software, of a 3D Bio-printer using syringe-based extruder and Core XY mechanism. Up to date, FDM is a popular technique because it is easily implemented, precise and accurate. The printed product revealed high repeativity, where (sample mean, sample standard deviation) is ( mm. The procedure could help future customized 3D Bio-printer.
- 1 June 2020
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 18 (3) , 1180-1187
Open AccessDevelopment of a 3D bio-printer using CoreXY mechanism and syringe-based extrusion
3D Bio-printer is said to have potential in the applications of medical studies and tissue engineering. A 3D Bio-printer could be used to print the artificial organs for organs transplant and cell tissue culture for generating new cell tissue. It could help in future medical and biological research. This paper presents the development process, i.e. working principle of Fused Deposition Modelling (FDM), mechanical, electrical and related applied software, of a 3D Bio-printer using syringe-based extruder and Core XY mechanism. Up to date, FDM is a popular technique because it is easily implemented, precise and accurate. The printed product revealed high repeativity, where (sample mean, sample standard deviation) is ( mm. The procedure could help future customized 3D Bio-printer.
- Open Access
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1883, 020033
Fall prevention walker during rehabilitation
This paper proposes on the design of a walker for the prevention of falling among elderlies or patients during rehabilitation whenever they use a walker to assist them. Fall happens due to impaired balance or gait problem. The assistive device is designed by applying stability concept and an accelerometric fall detection system is included. The accelerometric fall detection system acts as an alerting device that acquires body accelerometric data and detect fall. Recorded accelerometric data could be useful for further assessment. Structural strength of the walker was verified via iterations of simulation using finite element analysis, before being fabricated. Experiments were conducted to identify the fall patterns using accelerometric data. The design process and detection of fall pattern demonstrates the design of a walker that could support the user without fail and alerts the helper, thus salvaging the users from injuries due to fall and unattended situation.
- 1 January 2017
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1883, 020033
Open AccessFall prevention walker during rehabilitation
This paper proposes on the design of a walker for the prevention of falling among elderlies or patients during rehabilitation whenever they use a walker to assist them. Fall happens due to impaired balance or gait problem. The assistive device is designed by applying stability concept and an accelerometric fall detection system is included. The accelerometric fall detection system acts as an alerting device that acquires body accelerometric data and detect fall. Recorded accelerometric data could be useful for further assessment. Structural strength of the walker was verified via iterations of simulation using finite element analysis, before being fabricated. Experiments were conducted to identify the fall patterns using accelerometric data. The design process and detection of fall pattern demonstrates the design of a walker that could support the user without fail and alerts the helper, thus salvaging the users from injuries due to fall and unattended situation.