Timothy E. Morey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Timothy E. Morey has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Christoph N. Seubert
Department of Anesthesiology, College of Medicine, University of Florida, 1600 SW Archer Road, Gainesville, FL, 32610, USA
2 shared publications - Nikolaus Gravenstein
Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL, USA
2 shared publications - Terrie Vasilopoulos
Department of Orthopaedic Surgery & Sports Medicine, University of Florida, Gainesville, FL
2 shared publications - Anatoly E. Martynyuk
Department of Anesthesiology, College of Medicine, University of Florida, Gainesville, FL 32610, USA
1 shared publication - Ariane van der Straten
University of California, San Francisco
1 shared publication - Brian M. Ilfeld
Anesthesiology, University of California San Diego, La Jolla, California, USA
1 shared publication
Latest Publications
- Open Access
- 1 July 2017
- Published by Elsevier in Psychoneuroendocrinology
- Vol. 81, 96-104
Role of environmental stressors in determining the developmental outcome of neonatal anesthesia
- 1 July 2017
- Published by Elsevier in Psychoneuroendocrinology
- Vol. 81, 96-104
Open AccessRole of environmental stressors in determining the developmental outcome of neonatal anesthesia
- 1 August 2015
- Published by Wolters Kluwer Health in Survey of Anesthesiology
- Vol. 59 (4) , 196
Feasibility and Accuracy of Nasal Alar Pulse Oximetry
- 1 August 2015
- Published by Wolters Kluwer Health in Survey of Anesthesiology
- Vol. 59 (4) , 196
Feasibility and Accuracy of Nasal Alar Pulse Oximetry
- 16 January 2013
- Published by Springer Nature in AIDS and Behavior
- Vol. 17 (6) , 2211-2221
A Novel Breath Test to Directly Measure Use of Vaginal Gel and Condoms
We assessed the feasibility of a breath test to detect women’s single or concurrent use of vaginal products by adding ester taggants to vaginal gel and condom lubricant. Healthy non-pregnant women were enrolled into a two-day cohort (N = 13) and a single-day cohort (N = 12) in San Francisco. Within each cohort, women were randomized (5:1) to tagged or untagged products, and inserted in a clinical setting: 4 mL of tenofovir placebo gel (ten tagged with 15 mg 2-pentyl acetate; three untagged), and an artificial phallus with a lubricated condom (11 tagged with 15 mg 2-butyl acetate; two untagged), on two separate days (two-day cohort) or concurrently (single-day cohort). Using a portable mini-gas chromatograph, the presence/absence of taggants was determined in breath specimens collected prior to, and at timed intervals following product exposure. Demographic, clinical and product use experience data were collected by structured interview. All participants completed all visits and inserted their assigned products. At 5 min post-insertion, the breath test was 100 % accurate in identifying insertion of the tagged (or untagged) gel and/or condom. The half-life in breath of the two esters tested was N = 4) and scent (N = 5). The tagged products were well tolerated. This breath test has the potential to accurately and objectively monitor adherence to vaginal gel and condom used separately or concurrently. Se evaluó la viabilidad de una prueba de respiración para detectar, solo o concurrente, uso de los productos vaginales por mediante de las mujeres, añadiendo etiquetados éster al gel vaginal y lubricante de condón. Mujeres saludables, no embarazadas, se inscribieron en una cohorte de dos días (N = 13) y una cohorte de un solo día (N = 12) en San Francisco. Dentro de cada cohorte, mujeres fueron aleatorizadas (5:1) a productos, con o sin etiquetas, que fueron insertados dentro de un entorno clínico: 4 ml del gel placebo tenofovir (10 etiquetado con 15 mg de acetato de 2-pentilo; 3 sin etiqueta), y un falo artificial con un condón lubricado (11 etiquetado con 15 mg de 2-acetato de butilo; 2 no etiquetado), en dos días separados (cohorte de dos días), o concurrentemente (cohorte de un solo día). Usando un mini-cromatógrafo de gases portátil, la presencia / ausencia de etiquetados se determinaron en muestras de aliento recogidas antes de y a intervalos de tiempo, después de la exposición del producto. Datos demográficos, clínicos y de la experiencia sobre el uso del producto se recogieron mediante entrevista estructurada. Todos los participantes completaron todas las visitas y insertaron sus productos asignados. A los 5 minutos después de inserción, la prueba de alcoholemia fue 100% preciso en la identificación de la inserción, con o sin etiqueta, del gel y / o condón. El tiempo que tardo para la mitad de los ésters desglosar y ser eliminados del cuerpo por medio del aliento, de los dos ésteres que fueron usados para la prueba, fue <1 hora con una gran variabilidad entre los individuos, indicadores y cohortes. En general, entre los productos relacionados, etiquetados y recibidos, fueron reportados seis eventos adversos leve y dos moderados. Todos fueron transitorios y se resolvieron espontáneamente. Sensaciones adicionales incluyeron sabor en la boca (n = 4) y aroma (n = 5). Los productos etiquetados fueron bien tolerados. Esta respiración de ensayo es capaz de controlar con precisión y objetivamente la adherencia al gel vaginal y condón usado por separado o concurrentemente.
- 16 January 2013
- Published by Springer Nature in AIDS and Behavior
- Vol. 17 (6) , 2211-2221
A Novel Breath Test to Directly Measure Use of Vaginal Gel and Condoms
We assessed the feasibility of a breath test to detect women’s single or concurrent use of vaginal products by adding ester taggants to vaginal gel and condom lubricant. Healthy non-pregnant women were enrolled into a two-day cohort (N = 13) and a single-day cohort (N = 12) in San Francisco. Within each cohort, women were randomized (5:1) to tagged or untagged products, and inserted in a clinical setting: 4 mL of tenofovir placebo gel (ten tagged with 15 mg 2-pentyl acetate; three untagged), and an artificial phallus with a lubricated condom (11 tagged with 15 mg 2-butyl acetate; two untagged), on two separate days (two-day cohort) or concurrently (single-day cohort). Using a portable mini-gas chromatograph, the presence/absence of taggants was determined in breath specimens collected prior to, and at timed intervals following product exposure. Demographic, clinical and product use experience data were collected by structured interview. All participants completed all visits and inserted their assigned products. At 5 min post-insertion, the breath test was 100 % accurate in identifying insertion of the tagged (or untagged) gel and/or condom. The half-life in breath of the two esters tested was N = 4) and scent (N = 5). The tagged products were well tolerated. This breath test has the potential to accurately and objectively monitor adherence to vaginal gel and condom used separately or concurrently. Se evaluó la viabilidad de una prueba de respiración para detectar, solo o concurrente, uso de los productos vaginales por mediante de las mujeres, añadiendo etiquetados éster al gel vaginal y lubricante de condón. Mujeres saludables, no embarazadas, se inscribieron en una cohorte de dos días (N = 13) y una cohorte de un solo día (N = 12) en San Francisco. Dentro de cada cohorte, mujeres fueron aleatorizadas (5:1) a productos, con o sin etiquetas, que fueron insertados dentro de un entorno clínico: 4 ml del gel placebo tenofovir (10 etiquetado con 15 mg de acetato de 2-pentilo; 3 sin etiqueta), y un falo artificial con un condón lubricado (11 etiquetado con 15 mg de 2-acetato de butilo; 2 no etiquetado), en dos días separados (cohorte de dos días), o concurrentemente (cohorte de un solo día). Usando un mini-cromatógrafo de gases portátil, la presencia / ausencia de etiquetados se determinaron en muestras de aliento recogidas antes de y a intervalos de tiempo, después de la exposición del producto. Datos demográficos, clínicos y de la experiencia sobre el uso del producto se recogieron mediante entrevista estructurada. Todos los participantes completaron todas las visitas y insertaron sus productos asignados. A los 5 minutos después de inserción, la prueba de alcoholemia fue 100% preciso en la identificación de la inserción, con o sin etiqueta, del gel y / o condón. El tiempo que tardo para la mitad de los ésters desglosar y ser eliminados del cuerpo por medio del aliento, de los dos ésteres que fueron usados para la prueba, fue <1 hora con una gran variabilidad entre los individuos, indicadores y cohortes. En general, entre los productos relacionados, etiquetados y recibidos, fueron reportados seis eventos adversos leve y dos moderados. Todos fueron transitorios y se resolvieron espontáneamente. Sensaciones adicionales incluyeron sabor en la boca (n = 4) y aroma (n = 5). Los productos etiquetados fueron bien tolerados. Esta respiración de ensayo es capaz de controlar con precisión y objetivamente la adherencia al gel vaginal y condón usado por separado o concurrentemente.
- 1 February 2007
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 21 (1) , 57-60
Temperature-Related Differences in Mean Expired Pump and Arterial Carbon Dioxide in Patients Undergoing Cardiopulmonary Bypass
- 1 February 2007
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 21 (1) , 57-60
Temperature-Related Differences in Mean Expired Pump and Arterial Carbon Dioxide in Patients Undergoing Cardiopulmonary Bypass
- 1 July 2004
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 29 (4) , 371-376
New Portable Infusion Pumps
- 1 July 2004
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 29 (4) , 371-376
New Portable Infusion Pumps