NGNikolaus Gravenstein

Nikolaus Gravenstein

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nikolaus Gravenstein has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion

    by Mayank Kotadia, S Hamad Sagheer, Christopher Samouce, Rachael Ahn, Hannah Kavelak, Samsun Lampotang, Nikolaus Gravenstein

    Background: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. Methods: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. Results: Two-handed self-advancement yielded the lowest displacement (1.98 ± 1.14 mm), path length (3.93 ± 2.54 mm), and excursion (2.33 ± 1.21 mm). One-handed advancement produced larger displacement (2.54 ± 1.26 mm, p = 0.012), path length (9.23 ± 5.75 mm, p < 0.001), excursion (3.44 ± 1.70 mm, p = 0.002), and radial movement (0.74 ± 0.27 mm, p < 0.001 vs both other techniques). Two-person advancement matched two-handed lateral control but showed greater axial motion (1.65 ± 1.39 mm vs 0.78 ± 1.71 mm, p = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. Conclusions: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.

  • Open Access

    The RITE of Passage: Learning Styles and Residency In-Service Training Examination (RITE) Scores

    by Brenda G. Fahy, Jean E Cibula, Lou Ann Cooper, Samsun Lampotang, Nikolaus Gravenstein, Terrie Vasilopoulos

    The objective of the pilot study was to determine the association between learning preferences and improvement in the American Academy of Neurology Residency In-Service Training Examination (RITE) scores from postgraduate year 2 (PGY-2) to postgraduate year 3 (PGY-3) in neurology residents. Neurology residents at the University of Florida were approached to participate, and their consent was obtained. VARK inventory, representing four modalities (visual, aural, read/write, kinesthetic) of learning preferences, was completed by participants. Participants could pick more than one modality. The number of responses in each sensory domain was recorded, with higher numbers indicating stronger preference. Residents’ performance on the RITE was recorded for PGY-2 and PGY-3. Seventeen residents completed the VARK inventory and 16 had data for RITE. Residents demonstrated overall positive change in RITE from PGY-2 to PGY-3 (mean change = 6%; 95%CI: 4%, 9%). The median number of responses was highest for the kinesthetic domain (median = 7, range = 1-12), followed by visual (median = 6, range = 2-12), aural (median = 4, range = 1-10), and read/write (median = 4, range = 1-10). Among VARK domains, the number of responses in read/write had the strongest correlation with mean change in RITE performance from PGY-2 to PGY-3 (r = 0.45; 95%CI: -0.08, 0.78); residents in the high read/write group (number of response above median) had greater mean change in RITE performance (9%; 95%CI: 6%, 12%) while those in the low read/write group showed little to no increase in RITE from PGY-2 to PGY-3 (2%; 95%CI: -1%, 6%). Higher VARK survey responses in the read/write domain were related to greater change in RITE scores from PGY-2 to PGY-3. These findings seem intuitively obvious considering the format of the RITE. These pilot data permit further investigation of individual resident learning preference and how it relates to test performance. By understanding a resident’s learning style, both educators and the resident will have an awareness of areas that need to be improved to be successful, which may be via remedial curricula and self-study activities.


  • Open Access

    Role of environmental stressors in determining the developmental outcome of neonatal anesthesia

    by Ling-Sha Ju, Jiao-Jiao Yang, Nikolaus Gravenstein, Christoph N. Seubert, Timothy E. Morey, Colin Sumners, Terrie Vasilopoulos, Jian-Jun Yang, Anatoly E. Martynyuk


  • Gastric bypass under general anesthesia

    by T. Y. Euliano, J. S. Gravenstein, N. Gravenstein, D. Gravenstein

    Essential Anesthesia - by T. Y. Euliano June 2011

  • Open Access

    All Glucose Measurements Are Not Equal

    by Mark J. Rice, Andrew D. Pitkin, Nikolaus Gravenstein

    We read with interest the study by Bilotta et al. 1 comparing intensive insulin therapy to conventional treatment in two cohorts of neurosurgical patients. When an arterial catheter was not available for glucose determination, capillary blood was measured with the HemoCue point-of-care device (HemoCue, Angelholm, Sweden). This was a wise choice, as this system has been shown to be accurate, even at low glucose concentrations.2 What is not commonly appreciated is that most other point-of-care glucose measurement devices are not sufficiently accurate for critical care use, and that such devices originally approved and regulated for home self-monitoring by patients with diabetes have migrated into the hospital setting without further regulatory scrutiny. In fact, it has been specifically recommended that point-of-care devices designed for patient use at home, yet sometimes used in hospitals, should not be used in critically ill patients.3


  • Temperature-Related Differences in Mean Expired Pump and Arterial Carbon Dioxide in Patients Undergoing Cardiopulmonary Bypass

    by Yong G. Peng, Timothy E. Morey, Dale Clark, Matthew D. Forthofer, Nikolaus Gravenstein, Gregory M. Janelle