MSMakoto Sakama

Makoto Sakama

*This is an algorithmically generated author record based on publicly available information.

Makoto Sakama has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Nobuyuki Kanematsu

    Department of Accelerator and Medical Physics, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, 263-8555, JAPAN

    2 shared publications
  • Taku Inaniwa

    Department of Accelerator and Medical Physics, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Chiba, 263-8555, JAPAN

    2 shared publications
  • Anatoly B. Rosenfeld

    Centre for Medical Radiation Physics, University of Wollongong

    1 shared publication
  • Eiji Yoshida

    National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba, Chiba, 263-8555, JAPAN

    1 shared publication
  • Han Gyu Kang

    Department of Nuclear Medicine Science, National Institutes for Quantum and Radiological Science and Technology National Institute of Radiological Sciences, Imaging Physics Group, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba Japan, Chiba, Chiba, 263-8555, JAPAN

    1 shared publication
  • Hideyuki Mizuno

    National Institutes for Quantum Science and Technology, Chiba, Japan

    1 shared publication

Latest Publications

  • Three-dimensional computational evaluation of water-to-air mass stopping power ratio for therapeutic helium-, carbon-, oxygen-, and neon-ion beams and its application to patient-specific quality assurance

    by Taku Inaniwa, Makoto Sakama, Nobuyuki Kanematsu

    Objective. Current dosimetry protocols recommend a constant water-to-air mass stopping power ratio, s w,air , of 1.126 with an uncertainty of ±1.5% for light ions, irrespective of ion species and energy. This study aims to develop a computational framework to calculate three-dimensional s w,air distributions of helium-, carbon-, oxygen-, and neon-ion beams for patient specific quality assurance (PSQA), and to systematically investigate spatial variations in s w,air under clinically relevant conditions. Approach. A computational framework was developed to calculate three-dimensional s w,air distributions based on the Bragg-Gray approximation, together with three-dimensional dose distributions for treatment planning. The framework was validated against published datasets for a mono-energetic carbon-ion beam. Treatment plans were generated using helium-, carbon-, oxygen-, and neon-ion beams for rectangular targets with varying spread-out Bragg peak (SOBP) widths and depths, as well as for bone and soft tissue, head and neck, and ocular cases. The corresponding s w,air distributions were calculated in a water phantom and compared with the recommended value of 1.126. Main Results. The mean s w,air within the target increased for shallower targets with narrower SOBP widths. For all ion species, s w,air increased toward the distal end of the SOBP, with larger variations observed for heavier ion species. In neon-ion irradiations for shallow targets, s w,air occasionally exceeded the ±1.5% uncertainty range in a limited region near the distal end of the SOBP. In all other cases, s w,air remained within the uncertainty range. Similar trends were observed in clinical cases. Based on these results, when considering the mean s w,air within the target, the suitable fixed values were 1.128 for carbon and oxygen ions and 1.129 for helium and neon ions. Significance . The proposed computational framework enables three-dimensional, plan-specific evaluation of s w,air and provides a practical approach for improving the dosimetric accuracy in charged-particle therapy with helium, carbon, oxygen, and neon ions, especially for PSQA.

  • Feasibility study of secondary-electron-bremsstrahlung imaging with a knife-edge slit camera for range verification in carbon-ion therapy

    by Michiko Tsuda, Mitsutaka Yamaguchi, Yuto Nagao, Han Gyu Kang, Takuya Yabe, Eiji Yoshida, Taiga Yamaya, Makoto Sakama, Hideyuki Mizuno, Naoki Kawachi, et al.

    Secondary-electron-bremsstrahlung (SEB) imaging has been proposed as a method for in vivo range verification in particle therapy; however, insufficient detection sensitivity remains a major limitation, particularly under low-count conditions. In this study, we developed a knife-edge slit camera and evaluated its feasibility for carbon-ion beam range verification using one-dimensional SEB profiles. The camera consisted of a tungsten knife-edge slit collimator and a 16 × 16 Ce:GAGG scintillator array coupled to an 8 × 8 SiPM array. Experiments were performed at the Heavy Ion Medical Accelerator in Chiba using a 290 MeV/u carbon-ion beam irradiated onto a water phantom. One-dimensional SEB profiles were acquired for different beam ranges controlled by range shifters. The measured profiles shifted systematically with beam range. The profiles measured with range-shifter water-equivalent thicknesses of 0.00 and 5.27 mm were visually distinguishable. Calibration-based range estimation, evaluated by Poisson resampling of high-statistics measured profiles, yielded mean precisions of 2.76, 8.89, and 29.5 mm for 10 8 , 10 7 , and 10 6 incident carbon ions, respectively. These results demonstrate the feasibility of knife-edge slit SEB imaging for carbon-ion beam range verification and indicate that further improvement in detection sensitivity is required for measurements with smaller numbers of incident ions.

  • Evaluation of diamond and silicon detectors for linear energy transfer measurements of therapeutic helium, carbon, oxygen, and neon ion beams

    by Taku Inaniwa, Makoto Sakama, Sung Hyun Lee, Taku Nakaji, Nobuyuki Kanematsu, Linh T Tran, Anatoly Rosenfeld

    Objective. Diamond and silicon detectors are increasingly popular tools for dose-averaged linear energy transfer (LET) in water L ¯ w measurements of therapeutic ion beams. The LET measured in detector materials is linearly scaled to the LET in water using a calibration coefficient based on the mass stopping power ratio (MSPR) of water to detector material at a specific particle energy. However, because the MSPR varies with particle energy, this conventional conversion method introduces L ¯ w errors. This study aims to quantify these errors for helium, carbon, oxygen, and neon ion beams and to propose a conversion method to reduce them. Approach. Rectangular targets were defined within a water phantom, and treatment plans were generated using helium, carbon, oxygen, and neon ion beams to achieve uniform dose distributions within the targets. The L ¯ w distributions delivered to the water phantom by the ion beams were calculated. The dose-averaged LET distributions in water L ¯ w, DM and L ¯ w, Si measured by diamond and silicon detectors based on the conventional conversion method were also calculated. Furthermore, a conversion method incorporating the particle-energy dependence of the MSPR was applied to the silicon detector outputs to derive dose-averaged LET distributions L ¯ w, Si _ prop . These distributions were then compared with the corresponding L ¯ w distributions. Main results. Given the high water equivalence of diamond, L ¯ w, DM distributions agreed with the L ¯ w distributions within 1% accuracy across all ion beams. In contrast, the poor water equivalence of silicon resulted in L ¯ w, Si distributions up to 10.5% lower than the L ¯ w distributions within the targets. However, when the energy-dependent MSPR-based conversion method was employed, the L ¯ w, Si _ prop distributions obtained with the silicon detectors showed good agreement with the L ¯ w distributions across all ion beams. Significance. The energy-dependent MSPR-based conversion method is highly effective for silicon detectors, despite their inherently poor water-equivalence properties. Silicon detectors can be used as accurate L ¯ w detectors in ion-beam radiotherapy.