Ulas C. Coskun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ulas C. Coskun has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Beniamino Barbieri
ISS, Inc. (United States)
2 shared publications- Shih-Chu Jeff Liao
ISS, Inc. (United States)
2 shared publications - Yuansheng Sun
ISS, Inc. (United States)
2 shared publications - Chien-Sing Poon
Wright State University, Department of Biomedical Engineering, Dayton, Ohio, United States
1 shared publication Hailin Qiu
Orient KOJI Scientific (China)
1 shared publicationSunil Shah
ISS, Inc. (United States)
1 shared publication
Latest Publications
- 14 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11244, 112441C-47
Time-resolved mesoscopic imaging of a whole animal by FastFLIM
The mesoscopic scale is between microscopic and macroscopic scales. In life sciences, mesoscopic imaging allows scientists to record, track and study details of biological systems in the context of an organ, body part, or organism. Mesoscopic imaging techniques have been developed for medical and clinical research, such as drug delivery, cancer diagnosis, etc. Especially when combined with novel nanoparticles and organic dyes in the near-infrared spectral regime, the mesoscopic imaging can probe deeper parts of the animal body. Here, we describe a timeresolved mesoscopic imaging approach, which can image deep inside of the whole mouse noninvasively. In addition, it uses the FastFLIM technique to measure the lifetime of the fluorescent probe. Since the lifetime carries information about the probe’s local microenvironment such as temperature, pH, ion concentration, etc., the lifetime imaging map obtained by the FastFLIM-mesoscope allows tracking quantitative dynamics of the probes in the whole animal body. The technique can also be used for quantitative intrinsic NADH metabolism mapping for real time monitoring of mitochondrial function. Here, we will show mesoscopic-scale NADH imaging in an oral cancer model.
- 14 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11244, 112441C-47
Time-resolved mesoscopic imaging of a whole animal by FastFLIM
The mesoscopic scale is between microscopic and macroscopic scales. In life sciences, mesoscopic imaging allows scientists to record, track and study details of biological systems in the context of an organ, body part, or organism. Mesoscopic imaging techniques have been developed for medical and clinical research, such as drug delivery, cancer diagnosis, etc. Especially when combined with novel nanoparticles and organic dyes in the near-infrared spectral regime, the mesoscopic imaging can probe deeper parts of the animal body. Here, we describe a timeresolved mesoscopic imaging approach, which can image deep inside of the whole mouse noninvasively. In addition, it uses the FastFLIM technique to measure the lifetime of the fluorescent probe. Since the lifetime carries information about the probe’s local microenvironment such as temperature, pH, ion concentration, etc., the lifetime imaging map obtained by the FastFLIM-mesoscope allows tracking quantitative dynamics of the probes in the whole animal body. The technique can also be used for quantitative intrinsic NADH metabolism mapping for real time monitoring of mitochondrial function. Here, we will show mesoscopic-scale NADH imaging in an oral cancer model.
- 23 February 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10498, 104980W-31
FastFLIM, the all-in-one engine for measuring photoluminescence lifetime of 100 picoseconds to 100 milliseconds
Photoluminescence (PL) refers to light emission initiated by any form of photon excitation. PL spectroscopy and microscopy imaging has been widely applied in material, chemical and life sciences. Measuring its lifetime yields a new dimension of the PL imaging and opens new opportunities for many PL applications. In solar cell research, quantification of the PL lifetime has become an important evaluation for the characteristics of the Perovskite thin film. Depending upon the PL process (fluorescence, phosphorescence, photon upconversion, etc.), the PL lifetimes to be measured can vary in a wide timescale range (e.g. from sub-nanoseconds to microseconds or even milliseconds) – it is challenging to cover this wide range of lifetime measurements by a single technique efficiently. Here, we present a novel digital frequency domain (DFD) technique named FastFLIM, capable of measuring the PL lifetime from 100 ps to 100 ms at the high data collection efficiency (up to 140-million counts per second). Other than the traditional nonlinear leastsquare fitting analysis, the raw data acquired by FastFLIM can be directly processed by the model-free phasor plots approach for instant and unbiased lifetime results, providing the ideal routine for the PL lifetime microscopy imaging.
- 23 February 2018
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10498, 104980W-31
FastFLIM, the all-in-one engine for measuring photoluminescence lifetime of 100 picoseconds to 100 milliseconds
Photoluminescence (PL) refers to light emission initiated by any form of photon excitation. PL spectroscopy and microscopy imaging has been widely applied in material, chemical and life sciences. Measuring its lifetime yields a new dimension of the PL imaging and opens new opportunities for many PL applications. In solar cell research, quantification of the PL lifetime has become an important evaluation for the characteristics of the Perovskite thin film. Depending upon the PL process (fluorescence, phosphorescence, photon upconversion, etc.), the PL lifetimes to be measured can vary in a wide timescale range (e.g. from sub-nanoseconds to microseconds or even milliseconds) – it is challenging to cover this wide range of lifetime measurements by a single technique efficiently. Here, we present a novel digital frequency domain (DFD) technique named FastFLIM, capable of measuring the PL lifetime from 100 ps to 100 ms at the high data collection efficiency (up to 140-million counts per second). Other than the traditional nonlinear leastsquare fitting analysis, the raw data acquired by FastFLIM can be directly processed by the model-free phasor plots approach for instant and unbiased lifetime results, providing the ideal routine for the PL lifetime microscopy imaging.