Philippe Buttin
Philippe Buttin has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Bertrand Vedrine
Clinique Vétérinaire Seinevet, Boos, France
2 shared publications Fabrice Bernard
CHV Saint‐Martin Allonzier‐la‐Caille France
2 shared publications- Guillaume Ragetly
CHV Fregis Paris France
2 shared publications - Alexandre Fournet
Surgical Unit, Veterinary Hospital Massilia, Marseille, France
1 shared publication - Antonin Jean Johan Crumière
R&D Department, Novetech Surgery, Nice, France
1 shared publication Axelle Castelli
Surgical Unit, Veterinary Hospital Saint-Martin, Allonzier-la-Caille, France
1 shared publication
Latest Publications
- Open Access
- 22 May 2026
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. -1 (aop) , 1-2
A video guide to stabilization of canine hip luxation by intra-articular reconstruction of the round ligament using a synthetic implant
Objective: To provide video guidance on performing intra-articular repair of the round ligament with a synthetic implant to stabilize the coxofemoral joint following hip luxation in dogs. Animals: Dogs of any size with hip luxation associated with rupture of the round ligament. Methods: With the dog in lateral recumbency, a femoral tunnel is drilled from the base of the greater trochanter to the fovea capitis. A second femoral tunnel is drilled caudocranially, distal and perpendicular to the first one, midway between the medial and lateral cortices of the proximal femoral metaphysis. This tunnel is compacted with an interference screw intended for implant fixation. A third tunnel is drilled through the acetabulum at the footprint of the round ligament. An ultra-high-molecular-weight polyethylene (UHMWPE) implant preassembled with a cortical button is inserted through the acetabular tunnel, such that the button lies against the medial wall of the acetabulum. The implant is passed through the femoral tunnels, tensioned, and secured in the second femoral tunnel with the use of an interference screw inserted caudocranially. Results: This technique provides immediate stabilization and restores physiological mobility of the hip. Clinical Relevance: Hip luxation is a common traumatic lesion in small animals. The choice of surgical treatment depends on the type of hip luxation, which usually occurs in a craniodorsal direction and more rarely in a caudodorsal or caudoventral direction. Intra-articular repair replaces the torn round ligament with a biocompatible UHMWPE implant to restore the stability and mobility of the joint. This technique allows for treatment of all luxation types.
- 22 May 2026
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. -1 (aop) , 1-2
Open AccessA video guide to stabilization of canine hip luxation by intra-articular reconstruction of the round ligament using a synthetic implant
Objective: To provide video guidance on performing intra-articular repair of the round ligament with a synthetic implant to stabilize the coxofemoral joint following hip luxation in dogs. Animals: Dogs of any size with hip luxation associated with rupture of the round ligament. Methods: With the dog in lateral recumbency, a femoral tunnel is drilled from the base of the greater trochanter to the fovea capitis. A second femoral tunnel is drilled caudocranially, distal and perpendicular to the first one, midway between the medial and lateral cortices of the proximal femoral metaphysis. This tunnel is compacted with an interference screw intended for implant fixation. A third tunnel is drilled through the acetabulum at the footprint of the round ligament. An ultra-high-molecular-weight polyethylene (UHMWPE) implant preassembled with a cortical button is inserted through the acetabular tunnel, such that the button lies against the medial wall of the acetabulum. The implant is passed through the femoral tunnels, tensioned, and secured in the second femoral tunnel with the use of an interference screw inserted caudocranially. Results: This technique provides immediate stabilization and restores physiological mobility of the hip. Clinical Relevance: Hip luxation is a common traumatic lesion in small animals. The choice of surgical treatment depends on the type of hip luxation, which usually occurs in a craniodorsal direction and more rarely in a caudodorsal or caudoventral direction. Intra-articular repair replaces the torn round ligament with a biocompatible UHMWPE implant to restore the stability and mobility of the joint. This technique allows for treatment of all luxation types.
- Open Access
- 8 April 2026
- Published by Wiley in Veterinary Surgery
- Vol. 55 (4) , 752-762
Outcomes of 11 cats with Achilles tendon ( AT ) rupture repair treated with a synthetic ultra‐high‐molecular‐weight polyethylene ( UHMWPE )
Objective: To report the outcomes of cats treated for Achilles tendon (AT) rupture with a recently commercialized synthetic ultra‐high‐molecular‐weight polyethylene (UHMWPE) implant and no transarticular fixation. Study design: Retrospective multicenter study. Animals: A total of 11 cats (13 limbs). Methods: Medical records from seven veterinary centers were reviewed for cats undergoing AT repair with the Novaten implant between 2021 and 2024. Feline musculoskeletal pain index (FMPI) was used for long‐term assessment. Lameness, posture, and pain were assessed at perioperative (0–3 months), short‐term (3–6 months), and long‐term (>12 months) intervals. Statistical analysis used non‐parametric tests. Results: A total of 13 limbs in 11 cats met the inclusion criteria. All injuries involved the tendino‐osseous junction, with 7/13 (53.8%) complete ruptures. No intraoperative complications occurred. Postoperative external coaptation was used in 9/13 (69.2%) limbs (4/13 rigid splints, 5/13 soft padded) for a median duration of 6 weeks (range, 0–8 weeks). One calcaneal fracture due to implant malposition and one surgical site infection were reported at short‐term follow‐up. Long‐term follow‐up (median, 18.5 months; range, 12.1–33) showed 11/12 limbs achieving functional recovery and normal tarsal motion. Conclusion: Repair of Achilles tendon rupture in cats using a UHMWPE implant without rigid immobilization was associated with restoration of functional limb use, normal tarsal range of motion at long‐term follow‐up, and a low incidence of postoperative complications in this case series. Clinical significance: This technique may provide a reliable surgical option for cats with AT rupture, as it may minimize the need for external fixation or external coaptation and improve short‐term recovery.
- 8 April 2026
- Published by Wiley in Veterinary Surgery
- Vol. 55 (4) , 752-762
Open AccessOutcomes of 11 cats with Achilles tendon ( AT ) rupture repair treated with a synthetic ultra‐high‐molecular‐weight polyethylene ( UHMWPE )
Objective: To report the outcomes of cats treated for Achilles tendon (AT) rupture with a recently commercialized synthetic ultra‐high‐molecular‐weight polyethylene (UHMWPE) implant and no transarticular fixation. Study design: Retrospective multicenter study. Animals: A total of 11 cats (13 limbs). Methods: Medical records from seven veterinary centers were reviewed for cats undergoing AT repair with the Novaten implant between 2021 and 2024. Feline musculoskeletal pain index (FMPI) was used for long‐term assessment. Lameness, posture, and pain were assessed at perioperative (0–3 months), short‐term (3–6 months), and long‐term (>12 months) intervals. Statistical analysis used non‐parametric tests. Results: A total of 13 limbs in 11 cats met the inclusion criteria. All injuries involved the tendino‐osseous junction, with 7/13 (53.8%) complete ruptures. No intraoperative complications occurred. Postoperative external coaptation was used in 9/13 (69.2%) limbs (4/13 rigid splints, 5/13 soft padded) for a median duration of 6 weeks (range, 0–8 weeks). One calcaneal fracture due to implant malposition and one surgical site infection were reported at short‐term follow‐up. Long‐term follow‐up (median, 18.5 months; range, 12.1–33) showed 11/12 limbs achieving functional recovery and normal tarsal motion. Conclusion: Repair of Achilles tendon rupture in cats using a UHMWPE implant without rigid immobilization was associated with restoration of functional limb use, normal tarsal range of motion at long‐term follow‐up, and a low incidence of postoperative complications in this case series. Clinical significance: This technique may provide a reliable surgical option for cats with AT rupture, as it may minimize the need for external fixation or external coaptation and improve short‐term recovery.
- 1 March 2026
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 264 (3) , 1-8
Patellar ligament repair with ultra-high-molecular-weight polyethylene implant results in successful outcome in 9 dogs
Objective: To describe the outcomes of patellar ligament (PL) reconstruction with an ultra-high-molecular-weight polyethylene (UHMWPE) implant secured with an interference screw in dogs. Animals: Medical records from 7 referral centers were reviewed for dogs treated for PL rupture between 2021 and 2025. Cases treated exclusively with UHMWPE implants with a minimum follow-up of 6 months were included. Clinical Presentation: Dogs presented with lameness and examination findings consistent with PL rupture, confirmed by radiography in all cases. The data collected included diagnostic test findings, surgical technique, complications, follow-up, and outcomes. Canine Brief Pain Inventory scores were obtained at the final follow-up. Radiographic measurements were used to assess the patellar ligament length-to-patellar length ratio in operated and contralateral limbs over time. Results: 10 stifles from 9 dogs met the inclusion criteria. Median follow-up was 18 months (range, 1.5 to 3.8 years). No major complications were recorded. The patellar ligament length-to-patellar length ratio decreased after surgery. Return to activity was reported between 2 and 6 months postoperatively. Full function was recovered in 7 dogs; 2 dogs showed mild lameness beyond mid term. Canine Brief Pain Inventory scores in 8 dogs had a median of 4/100 (range, 0 to 26). Clinical Relevance: The UHMWPE implant provided effective repair without major complications in all 10 cases and resulted in acceptable to full functional outcomes in 9 dogs. The observed outcomes suggested that this technique could minimize the need for postoperative immobilization and may be associated with a low complication rate.
- 1 March 2026
- Published by American Veterinary Medical Association (AVMA) in Journal of the American Veterinary Medical Association
- Vol. 264 (3) , 1-8
Patellar ligament repair with ultra-high-molecular-weight polyethylene implant results in successful outcome in 9 dogs
Objective: To describe the outcomes of patellar ligament (PL) reconstruction with an ultra-high-molecular-weight polyethylene (UHMWPE) implant secured with an interference screw in dogs. Animals: Medical records from 7 referral centers were reviewed for dogs treated for PL rupture between 2021 and 2025. Cases treated exclusively with UHMWPE implants with a minimum follow-up of 6 months were included. Clinical Presentation: Dogs presented with lameness and examination findings consistent with PL rupture, confirmed by radiography in all cases. The data collected included diagnostic test findings, surgical technique, complications, follow-up, and outcomes. Canine Brief Pain Inventory scores were obtained at the final follow-up. Radiographic measurements were used to assess the patellar ligament length-to-patellar length ratio in operated and contralateral limbs over time. Results: 10 stifles from 9 dogs met the inclusion criteria. Median follow-up was 18 months (range, 1.5 to 3.8 years). No major complications were recorded. The patellar ligament length-to-patellar length ratio decreased after surgery. Return to activity was reported between 2 and 6 months postoperatively. Full function was recovered in 7 dogs; 2 dogs showed mild lameness beyond mid term. Canine Brief Pain Inventory scores in 8 dogs had a median of 4/100 (range, 0 to 26). Clinical Relevance: The UHMWPE implant provided effective repair without major complications in all 10 cases and resulted in acceptable to full functional outcomes in 9 dogs. The observed outcomes suggested that this technique could minimize the need for postoperative immobilization and may be associated with a low complication rate.