Estephania Lira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Estephania Lira has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Grespi
Division of Synchrotron Radiation Research, Lund University, Box 118, 22100 Lund, Sweden
5 shared publications - Lindsay Richard Merte
NanoLund Lund University Lund Sweden
5 shared publications - Edvin Lundgren
Division of Synchrotron Radiation Research, Lund University, Lund, Sweden
4 shared publications - Alfred Larsson
Leiden Institute of Chemistry, Leiden University, Leiden, The Netherlands
3 shared publications - Auden Ti
Division of Synchrotron Radiation Research, Lund University, Box 118, 22100 Lund, Sweden
3 shared publications - Giuseppe Abbondanza
Department of Physics, Chalmers University of Technology, Chalmersplatsen 4, 41296 Gothenburg, Sweden
2 shared publications
Latest Publications
- Open Access
- 28 September 2026
- Published by Wiley in Chemphyschem
- Vol. 27 (19)
An Ultrathin Hydroxide Film Governs the Stability and Reactivity of Gold for the Oxygen Evolution Reaction
Surface oxidation of noble metals under electrochemical conditions has a decisive impact on the performance of electrocatalysts for electrolyzers and fuel cells. However, the experimental detection of such oxides on well‐defined model electrodes under operando conditions is a major challenge, limiting our ability to establish clear structure–performance relationships. Using surface‐sensitive total‐reflection X‐ray absorption spectroscopy in real time during cyclic voltammetry, combined with inductively coupled plasma mass spectrometry dissolution measurements, we demonstrate that an ultrathin (~5 Å) hydroxide film forms on the gold (111) surface prior to the onset of the oxygen evolution reaction. This film, composed of Au 3+ in similar coordination as in the bulk oxyhydroxide, thus governs its catalytic properties, dissolution, and restructuring. The results highlight the importance of surface oxidation in water splitting catalysis even for Au(111), the most inert surface of the most inert noble metal.
- 28 September 2026
- Published by Wiley in Chemphyschem
- Vol. 27 (19)
Open AccessAn Ultrathin Hydroxide Film Governs the Stability and Reactivity of Gold for the Oxygen Evolution Reaction
Surface oxidation of noble metals under electrochemical conditions has a decisive impact on the performance of electrocatalysts for electrolyzers and fuel cells. However, the experimental detection of such oxides on well‐defined model electrodes under operando conditions is a major challenge, limiting our ability to establish clear structure–performance relationships. Using surface‐sensitive total‐reflection X‐ray absorption spectroscopy in real time during cyclic voltammetry, combined with inductively coupled plasma mass spectrometry dissolution measurements, we demonstrate that an ultrathin (~5 Å) hydroxide film forms on the gold (111) surface prior to the onset of the oxygen evolution reaction. This film, composed of Au 3+ in similar coordination as in the bulk oxyhydroxide, thus governs its catalytic properties, dissolution, and restructuring. The results highlight the importance of surface oxidation in water splitting catalysis even for Au(111), the most inert surface of the most inert noble metal.
- Open Access
- 1 May 2026
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 267, 460-479
Surface orientation-dependent electro-oxidation of a polycrystalline gold electrode
The electro-oxidation of a polycrystalline gold electrode is investigated in situ using two-dimensional surface optical reflectance, electrochemical near ambient pressure X-ray photoelectron spectroscopy, and tomographic surface X-ray diffraction.
- 1 May 2026
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 267, 460-479
Open AccessSurface orientation-dependent electro-oxidation of a polycrystalline gold electrode
The electro-oxidation of a polycrystalline gold electrode is investigated in situ using two-dimensional surface optical reflectance, electrochemical near ambient pressure X-ray photoelectron spectroscopy, and tomographic surface X-ray diffraction.
- Open Access
- 14 April 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (7) , 076502
Following the Electrochemical Oxidation of Au(111) in Real-Time Using Surface Optical Reflectance and Total-Reflection X-Ray Absorption Spectroscopy
Under electrochemical polarization, many electrocatalysts can undergo oxidation that alters their reactivity and can lead to restructuring and dissolution. In this context, the structure-property relationships of electrocatalysts, as well as their kinetics and dynamic behaviour, are still poorly understood. This knowledge gap mainly relies on the limitations of many traditional spectroscopic and structure determination methods, which cannot be easily coupled in situ with electrochemical methods. In this work, we performed cyclic voltammetry (CV) combined with 2D surface optical reflectance (2D-SOR) and total reflection X-ray absorption spectroscopy (RefleXAFS) in a single operando experiment, to directly follow the electro-oxidation and reduction of a Au(111) model electrode. Our results show that the surface in 0.05 M H 2 SO 4 forms a self-limiting Au 3+ oxide or hydroxide film around 1.5 V RHE during the anodic scan in the CV (2 mV s −1 ), with a thickness of ∼5 Å estimated from the 2D-SOR measurements. The film is then rapidly reduced during the cathodic scan around 1.1 V RHE .
- 14 April 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (7) , 076502
Open AccessFollowing the Electrochemical Oxidation of Au(111) in Real-Time Using Surface Optical Reflectance and Total-Reflection X-Ray Absorption Spectroscopy
Under electrochemical polarization, many electrocatalysts can undergo oxidation that alters their reactivity and can lead to restructuring and dissolution. In this context, the structure-property relationships of electrocatalysts, as well as their kinetics and dynamic behaviour, are still poorly understood. This knowledge gap mainly relies on the limitations of many traditional spectroscopic and structure determination methods, which cannot be easily coupled in situ with electrochemical methods. In this work, we performed cyclic voltammetry (CV) combined with 2D surface optical reflectance (2D-SOR) and total reflection X-ray absorption spectroscopy (RefleXAFS) in a single operando experiment, to directly follow the electro-oxidation and reduction of a Au(111) model electrode. Our results show that the surface in 0.05 M H 2 SO 4 forms a self-limiting Au 3+ oxide or hydroxide film around 1.5 V RHE during the anodic scan in the CV (2 mV s −1 ), with a thickness of ∼5 Å estimated from the 2D-SOR measurements. The film is then rapidly reduced during the cathodic scan around 1.1 V RHE .
- Open Access
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
A transfer cell for ultrahigh vacuum surface analysis of samples exposed to electrochemical environments
We present the design and implementation of a portable transfer system equipped with an integrated electrochemical cell that enables the controlled transfer of samples between an electrochemical environment and an ultrahigh vacuum (UHV) system without air exposure. This setup allows for the preparation of well-defined model surfaces, their electrochemical modification, and subsequent structural and chemical characterization using surface-sensitive UHV techniques. The system’s performance was validated using Au(111) as a model electrode. Cyclic voltammetry performed in a hanging meniscus configuration reproduced the characteristic oxidation and reduction features of Au(111), while scanning tunneling microscopy, low-energy electron diffraction, and Auger electron spectroscopy confirmed the structural and chemical integrity of the surface after transfer. Progressive surface roughening with increasing numbers of oxidation–reduction cycles followed an approximately linear trend, consistent with previous studies. In addition, we investigated the stability of gold oxide under vacuum and demonstrated that the thin oxide formed during anodic polarization, prior to the onset of the oxygen evolution reaction, is partially reduced during UHV transfer. X-ray photoelectron spectroscopy and Auger spectroscopy data indicate that the oxidized phase is stable in vacuum only after polarization at sufficiently high potentials, when continuous oxygen evolution is achieved via water electrolysis. Finally, successful integration and testing of the system at the FlexPES beamline at MAX IV confirmed its compatibility with synchrotron-based spectroscopy.
- 1 March 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (3)
Open AccessA transfer cell for ultrahigh vacuum surface analysis of samples exposed to electrochemical environments
We present the design and implementation of a portable transfer system equipped with an integrated electrochemical cell that enables the controlled transfer of samples between an electrochemical environment and an ultrahigh vacuum (UHV) system without air exposure. This setup allows for the preparation of well-defined model surfaces, their electrochemical modification, and subsequent structural and chemical characterization using surface-sensitive UHV techniques. The system’s performance was validated using Au(111) as a model electrode. Cyclic voltammetry performed in a hanging meniscus configuration reproduced the characteristic oxidation and reduction features of Au(111), while scanning tunneling microscopy, low-energy electron diffraction, and Auger electron spectroscopy confirmed the structural and chemical integrity of the surface after transfer. Progressive surface roughening with increasing numbers of oxidation–reduction cycles followed an approximately linear trend, consistent with previous studies. In addition, we investigated the stability of gold oxide under vacuum and demonstrated that the thin oxide formed during anodic polarization, prior to the onset of the oxygen evolution reaction, is partially reduced during UHV transfer. X-ray photoelectron spectroscopy and Auger spectroscopy data indicate that the oxidized phase is stable in vacuum only after polarization at sufficiently high potentials, when continuous oxygen evolution is achieved via water electrolysis. Finally, successful integration and testing of the system at the FlexPES beamline at MAX IV confirmed its compatibility with synchrotron-based spectroscopy.
- Open Access
- 1 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
A transfer cell for ultra-high vacuum surface analysis of samples exposed to electrochemical environments
We present the design and implementation of a portable transfer system equipped with an integrated electrochemical cell that enables the controlled transfer of samples between an electrochemical environment and an ultra-high vacuum (UHV) system without air exposure. This setup allows for the preparation of well-defined model surfaces, their electrochemical modification, and subsequent structural and chemical characterization using surface-sensitive UHV techniques. The system’s performance was validated using Au(111) as a model electrode. Cyclic voltammetry performed in a hanging meniscus configuration reproduced the characteristic oxidation and reduction features of Au(111), while scanning tunneling microscopy, low-energy electron diffraction, and Auger electron spectroscopy confirmed the structural and chemical integrity of the surface after transfer. Progressive surface roughening with increasing numbers of oxidation–reduction cycles followed an approximately linear trend, consistent with previous studies. Additionally, we investigated the stability of gold oxide under vacuum and demonstrated that the thin oxide formed during anodic polarization, prior to the onset of the oxygen evolution reaction, is partially reduced during UHV transfer. X-Ray Photoelectron Spectroscopy and Auger spectroscopy data indicate that the oxidized phase is stable in vacuum only after polarization at sufficiently high potentials, when continuous oxygen evolution is achieved via water electrolysis. Finally, successful integration and testing of the system at the FlexPES beamline at MAX IV confirmed its compatibility with synchrotron-based spectroscopy.
- 1 December 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessA transfer cell for ultra-high vacuum surface analysis of samples exposed to electrochemical environments
We present the design and implementation of a portable transfer system equipped with an integrated electrochemical cell that enables the controlled transfer of samples between an electrochemical environment and an ultra-high vacuum (UHV) system without air exposure. This setup allows for the preparation of well-defined model surfaces, their electrochemical modification, and subsequent structural and chemical characterization using surface-sensitive UHV techniques. The system’s performance was validated using Au(111) as a model electrode. Cyclic voltammetry performed in a hanging meniscus configuration reproduced the characteristic oxidation and reduction features of Au(111), while scanning tunneling microscopy, low-energy electron diffraction, and Auger electron spectroscopy confirmed the structural and chemical integrity of the surface after transfer. Progressive surface roughening with increasing numbers of oxidation–reduction cycles followed an approximately linear trend, consistent with previous studies. Additionally, we investigated the stability of gold oxide under vacuum and demonstrated that the thin oxide formed during anodic polarization, prior to the onset of the oxygen evolution reaction, is partially reduced during UHV transfer. X-Ray Photoelectron Spectroscopy and Auger spectroscopy data indicate that the oxidized phase is stable in vacuum only after polarization at sufficiently high potentials, when continuous oxygen evolution is achieved via water electrolysis. Finally, successful integration and testing of the system at the FlexPES beamline at MAX IV confirmed its compatibility with synchrotron-based spectroscopy.