YWYunbing Wang

Yunbing Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yunbing Wang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Daihua Fu

    National Engineering Research Center for Biomaterials and College of Biomedical Engineering Sichuan University Chengdu 610065 China

    1 shared publication
  • Jiayi Zhang

    National Engineering Research Center for Biomaterials and College of Biomedical Engineering Sichuan University Chengdu 610065 China

    1 shared publication
  • Yang Li

    Department of Vascular Surgery West China Hospital Sichuan University Chengdu 610041 China

    1 shared publication
  • Zhen Xiang

    National Engineering Research Center for Biomaterials and College of Biomedical Engineering Sichuan University Chengdu 610065 China

    1 shared publication

Latest Publications

  • Spatiotemporally Orchestrated H 2 S/NO‐Releasing Stent for Synergistic Vascular Healing

    by Jiayi Zhang, Yang Li, Zhen Xiang, Daihua Fu, Yunbing Wang

    Cardiovascular stents persistently struggle to reconcile rapid endothelialization with long‐term prevention of thrombosis and restenosis. This study develops a spatiotemporally orchestrated dual‐gas‐releasing hydrogel coating that synchronizes H 2 S and NO delivery with the dynamic phases of vascular healing. The coating is fabricated by covalently grafting an alginate coating onto poly(L‐lactic acid) stents via a benzophenone‐mediated two‐step surface photopolymerization. A thiol‑activated H 2 S donor is anchored within the coating, while alginate‑chelated Cu 2 ⁺ catalyzes NO generation from endogenous S‑nitrosothiols. An early H 2 S burst synergizes with NO to suppress thromboinflammation and prime a regenerative niche, while sustained NO release maintains vascular homeostasis and directs long‐term remodeling. The coating reduces platelet adhesion by over 90%, virtually eliminates thrombosis in an arteriovenous shunt model, triples endothelial coverage, and suppresses smooth muscle cell proliferation by ≈73%. It also reprograms macrophage polarization, increasing the M2/M1 ratio tenfold, and reduces intracellular ROS levels by >90%. In a rabbit abdominal aorta model, the coating promotes flow‐aligned endothelialization, achieving CD31⁺/eNOS⁺ coverage comparable to native tissue within 3 months, while decreasing neointimal thickness by 66% versus controls. This spatiotemporally tailored gasotransmitter delivery resolves the healing dichotomy of stents, providing a clinically translatable platform for next‐generation vascular implants.