Shuo Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuo Fu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Shuai Zhao
University of Science and Technology of China
2 shared publications - Huiyun Wang
Zhejiang Institute of Photoelectronics 2 , Jinhua 321004
1 shared publication Jie Chen
1 shared publication- Keqiang Qiu
University of Science and Technology of China
1 shared publication - Liang He
National Synchrotron Radiation Laboratory, University of Science and Technology of China 1 , Hefei 230029
1 shared publication Liu Zhengkun
1 shared publication
Latest Publications
- 3 July 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (15) , 27680
Two-dimensional Interferometric Metrology of Varied-line-spacing Gratings with Decoupled Substrate and Groove Contributions
Varied-line-spacing (VLS) gratings are pivotal optical components for achieving high energy resolution and focusing performance in synchrotron radiation monochromators and spectrometers. To optimize the operational performance and guide the high-precision manufacturing of these elements, comprehensive metrology of parameters such as groove density, groove bending, and substrate surface figure is essential. This work presents a high-precision, multi-parameter two-dimensional metrology system based on Fizeau interferometry. Specifically addressing the inherently curved diffraction wavefronts of VLS gratings, we implement a correction for retrace errors and investigate the measurement accuracy of VLS coefficients under a planar reference configuration. By analyzing the zero- and first-order diffraction wavefronts, the independent phase contributions of the grating grooves and the substrate figure are decoupled. Experimental validation on a 220 lines/mm grating (with a VLS coefficient a 1 = 0.041 lines/mm 2 ) demonstrates a groove density residual of only 0.0019 lines/mm and excellent agreement in groove bending compared with long trace profiler (LTP) results. This methodology provides a robust framework for the complete characterization of VLS gratings and offers an effective feedback mechanism for optimizing the fabrication of next-generation synchrotron optics.
- 3 July 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (15) , 27680
Two-dimensional Interferometric Metrology of Varied-line-spacing Gratings with Decoupled Substrate and Groove Contributions
Varied-line-spacing (VLS) gratings are pivotal optical components for achieving high energy resolution and focusing performance in synchrotron radiation monochromators and spectrometers. To optimize the operational performance and guide the high-precision manufacturing of these elements, comprehensive metrology of parameters such as groove density, groove bending, and substrate surface figure is essential. This work presents a high-precision, multi-parameter two-dimensional metrology system based on Fizeau interferometry. Specifically addressing the inherently curved diffraction wavefronts of VLS gratings, we implement a correction for retrace errors and investigate the measurement accuracy of VLS coefficients under a planar reference configuration. By analyzing the zero- and first-order diffraction wavefronts, the independent phase contributions of the grating grooves and the substrate figure are decoupled. Experimental validation on a 220 lines/mm grating (with a VLS coefficient a 1 = 0.041 lines/mm 2 ) demonstrates a groove density residual of only 0.0019 lines/mm and excellent agreement in groove bending compared with long trace profiler (LTP) results. This methodology provides a robust framework for the complete characterization of VLS gratings and offers an effective feedback mechanism for optimizing the fabrication of next-generation synchrotron optics.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
LTP-corrected stitching interferometer achieving sub-nanometer accuracy for x-ray mirror metrology
This paper presents a sub-nanometer accuracy stitching interferometry system for metrology of large curved x-ray mirrors, incorporating Long Trace Profiler (LTP) low-frequency correction. Utilizing a Fizeau interferometer with a reference transmission flat to measure sub-apertures of flat or curved optics, the system employs a mixed stitching method to achieve high-precision metrology of large x-ray mirrors. Crucially, the instrument overcomes cumulative angular errors in sub-aperture stitching through LTP-guided correction, achieving 0.18 nm RMS measurement repeatability validated on high-precision optics. After calibration of the transmission reference flat and zoom factor, the system demonstrates exceptional consistency with direct LTP measurements (<0.2 nm RMS), surpassing software-only techniques, while successfully verifying curved-mirror capability via <1% radius error measurement on spherical mirror with a radius of curvature of 24.6 m. For challenging elliptical synchrotron x-ray mirrors, our measurements of a specimen with 50 nrad RMS slope error and 0.5 nm RMS height error demonstrate excellent agreement with both manufacturer’s RADSI and LTP reference data. By eliminating angular drift propagation during the stitching process, this metrology system achieves sub-nanometer measurement accuracy for strongly curved x-ray optics.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
LTP-corrected stitching interferometer achieving sub-nanometer accuracy for x-ray mirror metrology
This paper presents a sub-nanometer accuracy stitching interferometry system for metrology of large curved x-ray mirrors, incorporating Long Trace Profiler (LTP) low-frequency correction. Utilizing a Fizeau interferometer with a reference transmission flat to measure sub-apertures of flat or curved optics, the system employs a mixed stitching method to achieve high-precision metrology of large x-ray mirrors. Crucially, the instrument overcomes cumulative angular errors in sub-aperture stitching through LTP-guided correction, achieving 0.18 nm RMS measurement repeatability validated on high-precision optics. After calibration of the transmission reference flat and zoom factor, the system demonstrates exceptional consistency with direct LTP measurements (<0.2 nm RMS), surpassing software-only techniques, while successfully verifying curved-mirror capability via <1% radius error measurement on spherical mirror with a radius of curvature of 24.6 m. For challenging elliptical synchrotron x-ray mirrors, our measurements of a specimen with 50 nrad RMS slope error and 0.5 nm RMS height error demonstrate excellent agreement with both manufacturer’s RADSI and LTP reference data. By eliminating angular drift propagation during the stitching process, this metrology system achieves sub-nanometer measurement accuracy for strongly curved x-ray optics.