Jacques Luce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jacques Luce has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Christelle Damiens-Dupont
CEA CESTA , F-33116 Le Barp
1 shared publication- Claude Rouyer
CEA CESTA , F-33116 Le Barp
1 shared publication - Florian Lochon
CEA CESTA , F-33116 Le Barp
1 shared publication - Hervé Coïc
CEA CESTA , F-33116 Le Barp
1 shared publication - Nathalie Blanchot
CEA CESTA , F-33116 Le Barp
1 shared publication Sandy Cavaro
CEA CESTA , F-33116 Le Barp
1 shared publication
Latest Publications
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Measuring the temporal contrast on the petawatt PETAL laser facility using a third-order cross-correlator diagnostic with 40 ps temporal range
In this paper, we present the architecture of a 40 ps, 107 dynamic range single-shot third-order cross-correlator for temporal contrast measurement of low repetition rate ultra-high intensity facilities. The cross-correlator employs a concatenation process to generate the complete 300 ps temporal contrast profile, using a limited number of shots. The shot-to-shot fluctuations in energy and pulse duration are deconvoluted. Simulations of the diagnostic’s achievable performance have been conducted, and an experimental demonstration is presented. The impact of phase and amplitude spectral defects on the diagnostic’s performance resolution will be discussed. To illustrate this point, a complete curve of the PETAL temporal contrast is obtained and discussed.
- 1 December 2025
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 96 (12)
Measuring the temporal contrast on the petawatt PETAL laser facility using a third-order cross-correlator diagnostic with 40 ps temporal range
In this paper, we present the architecture of a 40 ps, 107 dynamic range single-shot third-order cross-correlator for temporal contrast measurement of low repetition rate ultra-high intensity facilities. The cross-correlator employs a concatenation process to generate the complete 300 ps temporal contrast profile, using a limited number of shots. The shot-to-shot fluctuations in energy and pulse duration are deconvoluted. Simulations of the diagnostic’s achievable performance have been conducted, and an experimental demonstration is presented. The impact of phase and amplitude spectral defects on the diagnostic’s performance resolution will be discussed. To illustrate this point, a complete curve of the PETAL temporal contrast is obtained and discussed.