Володимир Забаровський
Research Subjects
Research Interests
Володимир Забаровський has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Daryna Karpova
National University of Civil Protection of Ukraine
1 shared publication - Oleksandr Zazymko
Institute of Scientific Research on Civil Protection of National University of Civil Protection of Ukraine
1 shared publication - Oleksii Basmanov
National University of Civil Protection of Ukraine
1 shared publication Vadym Benediuk
Institute of Scientific Research on Civil Protection of National University of Civil Protection of Ukraine
1 shared publicationVolodymyr Zabarovskiy
State Fire and Rescue Squad of the Main Directorate of the State Emergency Service of Ukraine
1 shared publication- Вадим Бенедюк
National University of Civil Defense of Ukraine
1 shared publication
Latest Publications
- Open Access
- 11 December 2025
- Published by National University of Civil Protection of Ukraine in Scientific bulletin: Сivil protection and fire safety
- No. 2(20),p. 4-13
Modeling the heating of an oil product tank under fire exposure from adjacent tanks in a tank group
The object of this study is the thermal processes occurring in a vertical steel tank containing petroleum products under the thermal influence of fires in several neighboring tanks within a tank group. To determine the temperature distribution over the tank surface and to calculate the time required for the wall or roof to reach the autoignition temperature of the stored liquid, the heat balance equations for the tank wall and roof were applied. The model accounts for radiative heat transfer from the fire, as well as radiative and convective heat exchange with the environment and the internal space of the tank. The radiating flame surface is modeled as a conical surface whose base expands leeward, and whose axis tilts when the wind speed exceeds a certain threshold. Fire scenarios involving a tank group of four identical tanks are considered. Using the example of RVS-10000 gasoline tanks, it is shown that a moderate wind speed – insufficient to tilt the flame axis – increases the heat flux to the tank and reduces the time required to reach hazardous temperature levels, even when the wind direction does not coincide with the direction from the fire to the target tank. In particular, at a wind speed of 2 m/s, the time to reach the autoignition temperature of gasoline vapors decreases by approximately 1.5 times compared to the calm conditions. At wind speeds sufficient to tilt the flame axis, the time to reach hazardous temperatures is significantly reduced if the wind tilts the flame toward the heated tank. At wind speeds above 4 m/s, this time decreases by 2–3 times. It is shown that when two tanks in a group are burning, the scenario in which the two burning tanks are located diagonally is more dangerous. The thermal impact of fires in three tanks is similar to that of two diagonally burning tanks, but the time for the remaining tank to reach critical temperatures is on average 20% shorter. The developed model can be used to identify the parts of the tank wall and roof that require cooling and to determine the maximum allowable time before initiating water cooling.
- 11 December 2025
- Published by National University of Civil Protection of Ukraine in Scientific bulletin: Сivil protection and fire safety
- No. 2(20),p. 4-13
Open AccessModeling the heating of an oil product tank under fire exposure from adjacent tanks in a tank group
The object of this study is the thermal processes occurring in a vertical steel tank containing petroleum products under the thermal influence of fires in several neighboring tanks within a tank group. To determine the temperature distribution over the tank surface and to calculate the time required for the wall or roof to reach the autoignition temperature of the stored liquid, the heat balance equations for the tank wall and roof were applied. The model accounts for radiative heat transfer from the fire, as well as radiative and convective heat exchange with the environment and the internal space of the tank. The radiating flame surface is modeled as a conical surface whose base expands leeward, and whose axis tilts when the wind speed exceeds a certain threshold. Fire scenarios involving a tank group of four identical tanks are considered. Using the example of RVS-10000 gasoline tanks, it is shown that a moderate wind speed – insufficient to tilt the flame axis – increases the heat flux to the tank and reduces the time required to reach hazardous temperature levels, even when the wind direction does not coincide with the direction from the fire to the target tank. In particular, at a wind speed of 2 m/s, the time to reach the autoignition temperature of gasoline vapors decreases by approximately 1.5 times compared to the calm conditions. At wind speeds sufficient to tilt the flame axis, the time to reach hazardous temperatures is significantly reduced if the wind tilts the flame toward the heated tank. At wind speeds above 4 m/s, this time decreases by 2–3 times. It is shown that when two tanks in a group are burning, the scenario in which the two burning tanks are located diagonally is more dangerous. The thermal impact of fires in three tanks is similar to that of two diagonally burning tanks, but the time for the remaining tank to reach critical temperatures is on average 20% shorter. The developed model can be used to identify the parts of the tank wall and roof that require cooling and to determine the maximum allowable time before initiating water cooling.