Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chengxin Li has a total of 100 co-authors. Here are the top co-authors by number of shared publications:

  • Jingqian Xi

    PGMF and School of Physics, MOE Key Laboratory of Fundamental Physical Quantities Measurement, Hubei Key Laboratory of Gravitation and Quantum Physics, Huazhong University of Science and Technology, Wuhan, China

    9 shared publications
  • Michael Kraft

    KU Leuven

    9 shared publications
  • Fangzheng Li

    MOE Key Laboratory of Fundamental Physical Quantities Measurement and the Hubei Key Laboratory of Gravitation and Quantum Physics, PGMF and School of Physics, Huazhong University of Science and Technology, Wuhan, China

    7 shared publications
  • Chen Wang

    Department of Electrical Engineering (ESAT-MNS),Leuven,Belgium,3001

    6 shared publications
  • Chen Wang

    Department of Electrical Engineering (ESAT-MNS), KU Leuven, Leuven, Belgium

    6 shared publications
  • Chun Zhao

    University of York,School of Physics, Engineering and Technology,Heslington,UK

    6 shared publications

Latest Publications

  • Open Access

    Enhancing Performance of a Novel Piezoelectric MEMS Microphone Through Single Diaphragm Mode Localization via Piezoelectric Layer Segmentation

    by Yuan Wang, Junchen Liu, Yancheng Lian, Huahuang Luo, Qingqing Ke, Xinrong Ouyang, Zhuoyue Zheng, Chengxin Li, Zhiyuan Yan, Xueyong Wei, et al.

    This study introduces a novel Aluminum Nitride (AlN) piezoelectric MEMS microphone featuring a piezoelectric layer segmentation comprising a circular, fully clamped membrane and multiple circular patterned electrodes. The innovative design achieves simultaneous multi-readout metrics without complex structures, size factors, or challenging manufacturing processes. By leveraging the unique single diaphragm mode-localization-like behavior of the architecture, the performance of the proposed subject is significantly enhanced. The proposed microphone was systematically characterized through electrical measurements and acoustic validation, demonstrating a distinct improvement in acoustic sensitivity compared to conventional counterparts. Baseline experiments over an acoustic pressure range of 0.16 Pa to 1.42 Pa show that the sensitivities measured by the outer electrodes of the proposed subject outperform those of the reference microphone, with the highest sensitivity reaching 66.74 ± 3.18 μV/Pa. Additionally, the sensitivities of the three inner electrodes were consistent across both devices, with the discrepancy being only 9.39 μV/Pa. The electrical characterization results reveal a weak coupling phenomenon in the first modal of the proposed device due to the engineered piezoelectric layer segmentation, facilitating a foundation for the mode-localization-like dynamics. As such, simultaneous multi-readout schemes can be garnered with respect to various acoustic disturbances, particularly encompassing infrasound regime (<1 Hz), i.e., amplitude modulation (AM), frequency modulation (FM), magnitude ratio (MR), frequency ratio (FR) and cross ratio (CR), in terms of both relative (Rel.) sensitivities and absolute (Abs.) sensitivities. Remarkably, a resolution of 16.24 nPa @ 1 Hz is achieved using the FR readout method, demonstrating a six-order-of-magnitude improvement over the AM metric. These findings underscore the effectiveness of piezoelectric layer segmentation in enhancing the performance of piezoelectric MEMS microphones without necessitating structural modifications or extra interface circuit and providing a pathway for design criteria of next-generation high-performance MEMS acoustic devices.

  • Dual-Mode Transduction–Induced Noise Correlation for Enhanced Fused Resolution in A Single Resonant Accelerometer

    by Chengxin Li, Fan Wu, Hemin Zhang, Chun Zhao, Bernardo Pereira Madeira, Chen Wang, Mustafa Mert Torunbalci, Lieven De Strycker, Michael Kraft

    Signal fusion between various sensors has been explored to enhance the robustness and resolution, leveraging their complementary characteristics. In general, a higher correlation between sensors leads to more efficient fusion. This work presents a silicon resonant accelerometer (SRA) that enables tunable noise correlation between capacitive and piezoresistive dual transductions. The accelerometer comprises a double clamped beam resonator with piezoresistive gauges and capacitive electrodes, allowing simultaneous transduction outputs of both signals. Through tuning the thermal bias applied to the piezoresistive gauges, the transduction gain of the piezoresistive signal can be tuned, enabling real-time control of the correlation between the two signals. The real-time frequencies demodulated from the signals with variable correlation are fused by using a general 2nd-order Kalman filter algorithm. Experimental results demonstrate that the fused output achieves a resolution of 0.49 µg/√Hz. This represents an improvement of approximately 10.45 dB compared with capacitive detection alone. Meanwhile, the fused signal preserves the broad bandwidth of ∼1150 Hz provided by piezoresistive detection. This highlights the effectiveness of noise correlation manipulation for enhancing sensor performance by output signal fusion.

  • A Hybrid Piezoelectric–Capacitive MEMS Microphone With Peripheral Electrostatic Transduction

    by Yangyang Guan, Chen Wang, Hemin Zhang, Sina Sadeghpour, Milad Shojaeian, Chengxin Li, Christ Glorieux, Michael Kraft

    This work proposes a piezoelectric –capacitive dual-mode micro-electromechanical system (MEMS) microphone with peripheral electrostatic transduction. Finite element analysis is used to investigate the contribution of the peripheral electrode configuration to the response characteristics of the proposed piezoelectric–capacitive MEMS microphone (PCMM). Piezoelectric transduction is achieved using a conventional piezoelectric stack with multiple layers. The capacitive transduction part is implemented through a peripheral electrode formed by the overlapping circumferential region between the silicon substrate and the device layer. The proposed PCMM shows a measured sensitivity of −51.1 dB (1 V/Pa) and a signal-to-noise ratio (SNR) of 49.6 dB at 1kHz (1 Pa) for the piezoelectric part, and −51.3 and 68.9 dB at 1kHz, respectively, for the capacitive part. Through the integration of dual outputs from the above two modes, the hybrid mode achieves measured sensitivities and SNR of −45.3 dB (1 V/Pa) and 55.3 dB (1kHz). The A-weighted SNR in the piezoelectric, capacitive, and hybrid modes is 10.53, 30.58, and 16.27 dB(A), respectively. At 145.6-dB SPL, the hybrid mode shows lower total harmonic distortion (THD) (1.7%) than the piezoelectric (2.6%) and capacitive (2.3%) modes.

  • A High Dynamic Range Electric Current Sensor With Transduction Efficiency Optimization

    by Chengxin Li, Hemin Zhang, Milad Shojaeian, Mustafa Mert Torunbalci, Chen Wang, Michael Kraft

    Capacitive-actuation and capacitive-detection (CACD) mechanisms have been adopted in MEMS electric current sensors (ECSs) for their favorable dynamic range (DR). However, parasitic capacitances inherent in capacitive transduction can degrade resolution and power efficiency. To address this limitation, this letter presents a high-performance ECS using capacitive-actuation and piezoresistive-detection (CAPD) architectures with optimized transduction efficiency. The ECS features a dual clamped-clamped beam with two symmetrically arranged piezoresistive gauges. The input current induces thermal strain in the first gauge, which is then transduced into a frequency shift detected by the second gauge. By optimizing the thermal bias applied to the sensing gauge, the transduction gain is maximized, enhancing resolution while minimizing power consumption. Experimental results demonstrate a 2.1-fold improvement in resolution to 9.1 nA/ $\surd $ Hz and a DR of 106.8dB, establishing a new benchmark for MEMS ECSs.[2025-0180]

  • Closed-Loop System Dual-Membrane for Mitigating Outgassing Induced Pressure Change in Infrared Sensors

    by Chen Wang, Kerkhofs Ward, Jietse van Thienen, Appo van der Wiel, Ben Maes, Chengxin Li, Michiel Gidts

    This study presents a novel closed-loop micro-electromechanical system infrared sensor that features dual-membranes, mitigating drift caused by the outgassing induced pressure change from the sensor hermetic package. Outgassing has an impact on the sensor thermal resistance. The closed-loop system controls the feedback heaters on the membrane directly to measure incident radiation, effectively eliminating the influence of thermal resistance on sensor performance. A comprehensive theoretical analysis and system-level modeling were performed. The sensor, along with the readout ASIC, was successfully fabricated on a single die. Experiments demonstrate that the closed-loop system reduces the effects of pressure change due to outgassing and input radiation on sensitivity by 24 times and 8 times, respectively. This method cancels sensor drift without increasing fabrication complexity, addressing a significant limitation of conventional infrared sensors and facilitating cost-effective packaging.

  • Machine Learning-Assisted Nonlinearity Decouoling for MEMS Resonators Within Closed-Loop Configuration

    by Chengxin Li, Fan Wu, Mustafa Mert Torunbalci, Hemin Zhang, Ruochen Ding, Helin Li, Milad Shojaeian, Chen Wang, Lieven De Strycker, Michael Kraft

    This paper presents a machine learning-based approach to decouple nonlinear effects in MEMS resonators operating in a closed-loop configuration. The resonator features capacitive-drive and piezoresistive-detection transduction, exhibiting mechanical nonlinear characteristics in both open-loop and closed-loop configurations. A multilayer perception (MLP) algorithm is trained to analyze the amplitude-frequency (A-f) response of the resonator in the nonlinear regime in open-loop configuration and estimate the key parameters of the nonlinear system. These parameters are then incorporated in a decoupling model to mitigate the nonlinear frequency shifts observed in closed-loop configuration. The experimental results show this approach enables the resonator to increase critical amplitudes in the nonlinear regime by 8 dB compared to closed-loop operation without decoupling, demonstrating its effectiveness in mitigating nonlinear effects.

  • A High-Resolution and Large-Bandwidth Resonant Accelerometer With Thermal Boost Sensitivity

    by Chengxin Li, Chen Wang, Hemin Zhang, Chun Zhao, Aojie Quan, Sina Sadeghpour, Mustafa Mert Torunbalci, Michael Kraft

    Capacitive actuation and piezoresistive detection (CAPD) mechanisms have been explored to enhance the bandwidth of resonant accelerometers, leveraging their high transduction gain to amplify weak signals. Despite these advantages, the stiffness of beams for the piezoresistive gauges poses a challenge to achieving high sensitivity and resolution. To address this limitation, this article presents a high-resolution resonant accelerometer with enhanced scale factor using a thermal boost approach to increase sensitivity. The accelerometer features a CAPD resonator consisting of a dual-clamped beam with two symmetrically arranged piezoresistive gauges. By applying a dc thermal voltage across these piezoresistive gauges, a thermal perturbation stiffness arises due to the resistance difference between the two gauges. This stiffness alters the coupling between the in-phase and out-of-phase modes of the resonator, enabling enhancements to the scale factor of the resonant accelerometer. Experimental results show that this approach significantly improves the scale factor from 975 to 2483 Hz/g and decreases the noise spectral density from 2.4 to $0.9~\mu $ g/ $\surd $ Hz, while maintaining a high bandwidth of 1000 Hz. This advancement highlights the effectiveness of thermal perturbation in boosting the scale factor and achieving a higher bandwidth-to-noise floor ratio of 1111 for resonant accelerometers.


  • Open Access

    Extracting mechanical quality factor and eliminating feedthrough using harmonics of thermal-piezoresistive micromechanical resonators

    by Geer Teng, Chenhao Yang, Aojie Quan, Chengxin Li, Haojie Li, Yuxuan Cheng, Honglong Chang, Michael Kraft, Hemin Zhang

    Thermal-actuation and piezoresistive-detection effects have been employed to pump the effective quality factor of MEMS resonators, targeting simple self-oscillation and better sensing performance in the air. However, the ratio of the pumped effective quality factor to the inherent mechanical quality factor, crucial for characterizing the amplification, is hard to obtain. The main difficulty stems from hidden Lorentz peaks caused by feedthrough effects and the pump effect once the current is applied. In this paper, we demonstrated the presence of high-order harmonic components in the output of thermal-piezoresistive resonators when the oscillation amplitude is sufficiently large. By utilizing second-order harmonics, we achieved the improvement in signal-to-bias ratio of, 20.85 dB compared to that without feedthrough cancellation and 9.67 dB compared to that using a de-embedded method when the bias current is 6.20 mA. Furthermore, the inherent mechanical quality factor is extracted at a low current of 1.8 mA with a value of 5800 using the second-order harmonics, and a nearly two orders of magnitude enhancement in Q factor can be obtained before entering the self-oscillation regime. An amplitude bias instability as good as 55 ppm and a frequency bias instability as good as 10 ppb are realized in the nonlinear operation regime with a pumped effective quality factor of 576k. The paper contributes to the fundamental understanding of the Q pump effect together with harmonic analysis of the thermal-piezoresistive resonators and also pushes forward the development of low-power consumption self-oscillation resonant sensors.


  • Improving the Performance of MEMS Resonant Sensors with Synchronized Piezoresistive/Capacitive Transductions using Signal Fusion

    by Chengxin Li, Fan Wu, Chun Zhao, Hemin Zhang, Mustafa Mert Torunbalci, Chen Wang, Lieven De Strycker, Michael Kraft

    This paper presents a novel MEMS resonant sensor simultaneously employing piezoresistive and capacitive transductions to generate high-correlation intrinsic noise and signal outputs. The design enables significant flicker noise reduction with a generic recursive filter. The sensor features a double tuning-ending fork resonator with dual piezoresistive gauges that transduces the signals synchronously via both piezoresistive and capacitive mechanisms. The synchronized signals extracted from the two transduction mechanisms are fused with a Kalman filter implemented in a FPGA. The experimental results demonstrate a frequency bias instability of 1.9 ppb with the application of signal fusion, which is a 20-fold improvement compared to using capacitive transduction alone.


  • A Novel 3-DoF Mode Localized BAW Resonant Mass Sensor With High Quality Factor and Resolution

    by Linlin Wang, Aojie Quan, Yuan Wang, Bernardo Pereira Madeira, Chengxin Li, Michael Kraft, Chen Wang

    This article presents a mass sensor based on a 3-degree-of-freedom (DoF) mode localized piezoelectric bulk acoustic wave (BAW) resonator system operating in the contour extensional mode. It features a quality factor of $\sim$ 4200 under atmospheric pressure at a resonance frequency of $\sim$ 6.36 MHz. More than three orders of magnitude enhancement ( $\sim$ 1700 times) of the normalized mass sensitivity based on the amplitude ratio (AR) change were achieved compared to that based on the frequency shift. The mass resolution thereof was obtained as 1.2 pg (for the AR change output) and 0.727 pg (for the frequency shift output), respectively. Compared with the previously reported mass sensor based on coupled BAW resonators, the presented device achieved an enhanced performance in terms of both quality factor ( $\sim$ 2.37 times higher), stability ( $\sim$ 100 and $\sim$ 3.5 times better for the AR change and frequency shift), and mass resolution ( $\sim$ 307 and $\sim$ 2.97 times better for the AR change and frequency shift). Moreover, the stability of the 3-DoF system with the AR change output was enhanced since there was only a $\sim$ 1.65-fold difference in the mass resolution in terms of the frequency shift and AR change, compared to $\sim$ 170-fold in the previous study. Furthermore, the novel device operated with a Q-factor of $\sim$ 305 in deionized (DI) water, demonstrating the considerable potential of such devices for future sensing applications in a liquid environment.