Zhi-Fa Feng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhi-Fa Feng has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Jia-Qiang Zhong
Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing, China
3 shared publications - Wei Miao
Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing, China
3 shared publications - Wen Zhang
Chinese Academy of Sciences
3 shared publications Jing Li
Purple Mountain Observatory, CAS
2 shared publications- Peizhan Li
Purple Mountain Observatory, CAS
2 shared publications - Sheng-Cai Shi
Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing, China
2 shared publications
Latest Publications
- 1 September 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (9) , 095019
Development of a microwave SQUID multiplexer for superconducting transition-edge sensor bolometer arrays
A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.
- 1 September 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (9) , 095019
Development of a microwave SQUID multiplexer for superconducting transition-edge sensor bolometer arrays
A microwave SQUID multiplexer ( μ MUX) with a high multiplexing factor is a promising readout approach for large-scale superconducting transition-edge sensor (TES) bolometer arrays. This paper reports on the characteristics of 16-channel μ MUX prototype chips and a 60-channel readout module developed to read out TES bolometers for the Ali cosmic microwave background polarization telescope (AliCPT). We designed two different coupling structures between the resonator and the radio-frequency superconducting interference device: design A with a mutual inductance ( M T ) of 2.3 pH and design B with an M T of 6.5 pH. For design A, the mean resonator bandwidth ( Δ f BW ) and peak-to-peak frequency shift ( Δ f pp ) are approximately 610 kHz and 290 kHz, respectively. The measured mean open-loop current noise is less than 40 pA / Hz . Preliminary results indicate that crosstalk between adjacent channels is below 1% in our design A μ MUX chip. A measured channel with design B shows a Δ f BW of 586 kHz and a current noise of 33 pA / Hz , similar to the design A channels. In comparison, the Δ f pp of 803 kHz is much larger than the design A channels due to a larger M T . The readout module, consisting of two design A chips and two design B chips, shows 60 resonances, corresponding to a yield of 94%. In the future, we will place 32 design A channels within the same chip dimension to increase the channel density and build a larger readout module suitable for AliCPT TES arrays.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Development of Microwave SQUID Multiplexer for Readout of Transition-Edge Sensor Array
Superconducting transition-edge sensors (TESs) with high sensitivity can detect electromagnetic wave radiations from millimeter/submillimeter, optical to x/γ rays, and have been successfully used in many fields. To improve detection efficiency and sensitivity, large-scale TES arrays are required in combination with multiplexing readout electronics. Compared to other multiplexing schemes, microwave SQUID multiplexing (μMUX), consisting of high-quality microwave superconducting resonators and RF SQUIDs, is most suitable since it provides a wider bandwidth (GHz) and consequently higher multiplexing factor. We designed two types of circuits with different mutual inductances (${{M}_{\mathrm{T}}}$) between the resonator and the RF SQUID: 2.3 pH for the weak-coupling channel and 6.5 pH for the strong-coupling channel. The resonator and RF SQUID washers made of 150 nm Nb are first fabricated by magnetron-sputtering and reactive ion etching, followed by the deposition of Nb/Al–AlOx/Nb trilayer and definition of the Josephson junctions of the RF SQUIDs. This work presents a μMUX demonstration chip with five channels with ${{Q}_{\mathrm{l}}}$ values of 787 and 3626, and the measured frequency shifts ($\Delta {{f}_{\text{pp}}}$) of ∼500 kHz and 4 MHz for the weak- coupling and strong-coupling channels, respectively. The open-loop equivalent noise current, obtained from the measured phase noise and resonator responsivity, is $\sim 80\text{pA}/\sqrt {\text{Hz}} $ with the strong-coupling channel.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (6) , 1-6
Development of Microwave SQUID Multiplexer for Readout of Transition-Edge Sensor Array
Superconducting transition-edge sensors (TESs) with high sensitivity can detect electromagnetic wave radiations from millimeter/submillimeter, optical to x/γ rays, and have been successfully used in many fields. To improve detection efficiency and sensitivity, large-scale TES arrays are required in combination with multiplexing readout electronics. Compared to other multiplexing schemes, microwave SQUID multiplexing (μMUX), consisting of high-quality microwave superconducting resonators and RF SQUIDs, is most suitable since it provides a wider bandwidth (GHz) and consequently higher multiplexing factor. We designed two types of circuits with different mutual inductances (${{M}_{\mathrm{T}}}$) between the resonator and the RF SQUID: 2.3 pH for the weak-coupling channel and 6.5 pH for the strong-coupling channel. The resonator and RF SQUID washers made of 150 nm Nb are first fabricated by magnetron-sputtering and reactive ion etching, followed by the deposition of Nb/Al–AlOx/Nb trilayer and definition of the Josephson junctions of the RF SQUIDs. This work presents a μMUX demonstration chip with five channels with ${{Q}_{\mathrm{l}}}$ values of 787 and 3626, and the measured frequency shifts ($\Delta {{f}_{\text{pp}}}$) of ∼500 kHz and 4 MHz for the weak- coupling and strong-coupling channels, respectively. The open-loop equivalent noise current, obtained from the measured phase noise and resonator responsivity, is $\sim 80\text{pA}/\sqrt {\text{Hz}} $ with the strong-coupling channel.
- Open Access
- 1 December 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (12)
A TES single-photon detector demonstrating high-energy-resolution, high efficiency, and ultra-low dark counts near 0.9 T c
Transition-edge sensors (TESs) are among the most promising technologies for single-photon detection, offering high quantum efficiency, low dark count rates, and energy-resolving capabilities. However, optimal TES performance typically requires ultra-low temperatures below 100 mK, necessitating bulky dilution refrigerators or adiabatic demagnetization refrigerators, which limits their practical deployment. In this work, we demonstrate a titanium-based TES optimized for 1064 nm photon detection that achieves high performance at an elevated bath temperature of 220 mK—approximately 90% of its superconducting transition temperature, making it compatible with more compact sorption refrigerators. Through the integration of an optical cavity, a detailed complex impedance and noise characterization, and a systematic investigation of dark count sources, the detector achieves a system detection efficiency exceeding 97%, an energy resolution of 240 meV, and an intrinsic dark count rate as low as 2 × 10−4 cps. These findings significantly expand the applicability of TES single-photon detectors to practical photon-counting systems, such as quantum information and infrared astronomy.
- 1 December 2025
- Published by AIP Publishing in APL Photonics
- Vol. 10 (12)
Open AccessA TES single-photon detector demonstrating high-energy-resolution, high efficiency, and ultra-low dark counts near 0.9 T c
Transition-edge sensors (TESs) are among the most promising technologies for single-photon detection, offering high quantum efficiency, low dark count rates, and energy-resolving capabilities. However, optimal TES performance typically requires ultra-low temperatures below 100 mK, necessitating bulky dilution refrigerators or adiabatic demagnetization refrigerators, which limits their practical deployment. In this work, we demonstrate a titanium-based TES optimized for 1064 nm photon detection that achieves high performance at an elevated bath temperature of 220 mK—approximately 90% of its superconducting transition temperature, making it compatible with more compact sorption refrigerators. Through the integration of an optical cavity, a detailed complex impedance and noise characterization, and a systematic investigation of dark count sources, the detector achieves a system detection efficiency exceeding 97%, an energy resolution of 240 meV, and an intrinsic dark count rate as low as 2 × 10−4 cps. These findings significantly expand the applicability of TES single-photon detectors to practical photon-counting systems, such as quantum information and infrared astronomy.