Qingyang Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qingyang Cheng has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Huaiyuan Guo
School of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 201100, China
2 shared publications - Junlong Meng
School of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 201100, China
2 shared publications - Junwen Yu
School of Automation and Intelligent Sensing, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Ming Yang
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
2 shared publications - Yuan Liu
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
2 shared publications - Yuanfei Zhu
Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 31 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 438
Design of a Motor-Torsion Driven 3D-Printed Left Ventricular Mock Circulation System and Hemocompatibility Assessment
In vitro testing of ventricular assist devices, constructing a mock circulation system that reproduces physiological cardiac function, is critical. However, current ventricular simulators often lack biomimetic fidelity and may introduce hemolysis and coagulation risks during prolonged operation, affecting hemocompatibility assessment. This study proposes a motor-driven torsional 3D-printed left ventricular simulator to reconstruct the hemodynamics of severe heart failure and related pathological conditions. The system integrates a 3D-printed elastic ventricular model with programmable torsional actuation, allowing the simulation of various cardiac conditions by adjusting the motor torsion angle and rotational speed, peripheral resistance and compliance. Fresh porcine blood was circulated for 4 h in a closed-loop system, with periodic measurements of plasma-free hemoglobin (PfHb), thrombin–antithrombin complex (TAT), and P-selectin. The results show that the system successfully reproduces typical hemodynamic features of severe heart failure, while hemolysis and coagulation markers remain low. After 4 h, PfHb was below 20 mg/dL, with no significant platelet activation or thrombosis. This study demonstrates that the proposed system enhances biomimicry while maintaining excellent hemocompatibility, offering a reliable platform for in vitro performance and safety evaluation of ventricular assist devices.
- 31 December 2025
- Published by MDPI AG in Applied Sciences
- Vol. 16 (1) , 438
Open AccessDesign of a Motor-Torsion Driven 3D-Printed Left Ventricular Mock Circulation System and Hemocompatibility Assessment
In vitro testing of ventricular assist devices, constructing a mock circulation system that reproduces physiological cardiac function, is critical. However, current ventricular simulators often lack biomimetic fidelity and may introduce hemolysis and coagulation risks during prolonged operation, affecting hemocompatibility assessment. This study proposes a motor-driven torsional 3D-printed left ventricular simulator to reconstruct the hemodynamics of severe heart failure and related pathological conditions. The system integrates a 3D-printed elastic ventricular model with programmable torsional actuation, allowing the simulation of various cardiac conditions by adjusting the motor torsion angle and rotational speed, peripheral resistance and compliance. Fresh porcine blood was circulated for 4 h in a closed-loop system, with periodic measurements of plasma-free hemoglobin (PfHb), thrombin–antithrombin complex (TAT), and P-selectin. The results show that the system successfully reproduces typical hemodynamic features of severe heart failure, while hemolysis and coagulation markers remain low. After 4 h, PfHb was below 20 mg/dL, with no significant platelet activation or thrombosis. This study demonstrates that the proposed system enhances biomimicry while maintaining excellent hemocompatibility, offering a reliable platform for in vitro performance and safety evaluation of ventricular assist devices.
- Open Access
A Deep Reinforcement Learning-Optimized Blood Flow Profile for Enhanced Oxygenation Efficiency in Membrane Oxygenators
The membrane oxygenator serves as the core component of extracorporeal life support systems, and its gas exchange efficiency critically influences clinical outcomes. However, gas transfer is predominantly limited by the diffusion barrier within the blood-side boundary layer, where saturated red blood cells accumulate. Current research focuses mainly on static approaches such as optimizing fiber bundle configuration to promote passive blood mixing or modifying material properties, which are fixed after fabrication. In contrast, dynamic blood flow control remains an underexplored avenue for enhancing oxygenator performance. This study proposes an active pulsatile flow control method that disrupts the boundary layer barrier by optimizing periodic flow profiles, thereby directly improving gas exchange. A deep reinforcement learning framework integrating proximal policy optimization and long short-term memory networks was developed to autonomously search for optimal flow waveforms under constant flow conditions. A simplified stacked-plate membrane oxygenator was specially designed as the experimental platform to minimize flow path interference. Experimental results demonstrate that the optimized pulsatile profile increases the oxygen transfer rate by without compromising hemocompatibility.Open AccessA Deep Reinforcement Learning-Optimized Blood Flow Profile for Enhanced Oxygenation Efficiency in Membrane Oxygenators
The membrane oxygenator serves as the core component of extracorporeal life support systems, and its gas exchange efficiency critically influences clinical outcomes. However, gas transfer is predominantly limited by the diffusion barrier within the blood-side boundary layer, where saturated red blood cells accumulate. Current research focuses mainly on static approaches such as optimizing fiber bundle configuration to promote passive blood mixing or modifying material properties, which are fixed after fabrication. In contrast, dynamic blood flow control remains an underexplored avenue for enhancing oxygenator performance. This study proposes an active pulsatile flow control method that disrupts the boundary layer barrier by optimizing periodic flow profiles, thereby directly improving gas exchange. A deep reinforcement learning framework integrating proximal policy optimization and long short-term memory networks was developed to autonomously search for optimal flow waveforms under constant flow conditions. A simplified stacked-plate membrane oxygenator was specially designed as the experimental platform to minimize flow path interference. Experimental results demonstrate that the optimized pulsatile profile increases the oxygen transfer rate by without compromising hemocompatibility.