NNNermeen Nagi

Nermeen Nagi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nermeen Nagi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Validation of the dental esthetic screening index in relation to patient-reported psychosocial outcomes and social perception ratings: A cross-sectional multicenter study

    by Fatma E.A. Hassanein, Asmaa Abou-Bakr, Nermeen Nagi, Mohamed Aboheikal, Mohamed Mofreh Hamed, Amr Edress, Mai Mohamed Elgendi, Sultan Binalrimal, Yousra Ahmed


  • Open Access

    Fractographic analysis of 3D printed hybrid ceramic single crowns with different aging and post-curing times: an in-vitro study

    by Salma Hatem, Bassem Emad, Nermeen Nagi, Aliaa Ibrahim Mahrous

    Since increasing 3D-printed ceramics are being introduced to restorative dentistry, a critical evaluation of fabrication parameters for optimal clinical performance is necessary. While post-curing treatments have some influence on material properties, their impact on fracture resistance is not clear. This in vitro study aimed to systematically evaluate the effects of different post-curing times (10 vs. 20 min) and thermocycling aging (5,000 vs. 10,000 cycles) on the fracture resistance and failure modes of 3D-printed hybrid ceramic crowns (Saremco CrownTec). CAD software was utilized to create a standardized digital model of a mandibular first premolar crown. Eighty identical samples were produced with a high-precision 3D printer (Asiga Max UV) using Saremco Print Crowntec hybrid ceramic material. Samples were randomly allocated to two major groups according to post-curing time in a UV polymerization unit (10 min vs. 20 min). Each group was then assigned to two subgroups ( n = 20 each) for thermocycling treatment (5,000 or 10,000 cycles between 5 °C and 55 °C). All crowns were adhesively cemented on PEEK dies with standardized preparation geometry. Fracture resistance testing was accomplished with a universal testing machine (Instron 5966) using a 5.6 mm steel ball indenter at 0.5 mm/min crosshead speed. Failure modes were examined using scanning electron microscopy SEM. Statistical analysis was conducted using two-way ANOVA (α = 0.05). The 10-minute post-cure group showed slightly greater mean fracture resistance (506.36 ± 58.44 N) than the 20-minute group (492.50 ± 76.06 N), but the difference was not statistically significant ( p = 0.428). Thermocycling analysis showed that specimens that underwent 5,000 cycles had slightly better fracture resistance (510.00 ± 72.36 N) than those which underwent 10,000 cycles (488.26 ± 62.64 N), but the difference was also not statistically significant ( p = 0.250). The failure patterns were reported and analyzed with SEM, based on extensions of failures on the axial surface. Although long post-curing times and thermocycling aging exhibited tendencies for decreased fracture resistance, the effects were not statistically significant under the parameters tested. Research in the future should examine the influence of various post-curing intensities and extended aging simulations to further support these results.


  • Open Access

    Comparative evaluation of fracture resistance of different CAD/CAM fabricated endocrowns - in vitro study

    by Nermeen Nagi

    Background: The aim of the study was to compare the fracture resistance of recent CAD/CAM restorative materials that recently used for the fabrication of endocrown restorations.Methods: 30 endocrowns were fabricated on 3D printed resin dies and divided into three groups (n=10) according to the endocrown material. Group A: lithium disilicate Endocrowns (IPS E-max CAD), Group B: resin infiltrated ceramic (Vita Enamic), and group C: Nanohybrid composite (Brilliant Crios). All endocrowns were subjected to axial compressive strength using a universal testing machine, until failure, and the values were recorded. Fracture resistance values in Newton (N) and failure modes of the restorations were evaluated using an optical microscope. All collected data were tabulated and statistically analyzed. Numerical data were described as mean and standard deviation and compared using a Two-way ANOVA test. The level of significance was set at α P≤0.05.Results: fracture resistance values of all tested materials were within the acceptable clinical range for all groups. The lithium disilicates endocrowns showed statistically significantly higher mean fracture resistance values than the polymer infiltrated and nanohybrid composite endocrowns. While the nanohybrid composite Endocrowns showed better mode of fracture than that of lithium disilicate. Conclusions: Within the limitations of this study, Emax endocrowns showed better fracture resistance followed by Vita enamic endocrowns. While brilliant crios Endocrowns revealed a better mode of failure despite it’s low fracture resistance values.