Emanuel Ewerton Mendonça Vasconcelos has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Gabriela Queiroz de Melo Monteiro
Faculty of Dentistry, Postgraduate Program in Dentistry University of Pernambuco (UPE) Recife Pernambuco Brazil
5 shared publications - Luís Felipe Espíndola-Castro
Faculty of Dentistry Federal University of Pernambuco Recife Pernambuco Brazil
5 shared publications - André Galembeck
Department of Fundamental Chemistry, Federal University of Pernambuco (UFPE), Av. Jorn. Aníbal Fernandes, Cidade Universitária, Recife 50740-560, Pernambuco, Brazil
2 shared publications - Fernanda Donida Ortigoza
Faculty of Dentistry Federal University of Pernambuco Recife Pernambuco Brazil
2 shared publications - Natália Gomes de Oliveira
School of Dentistry Universidade de Pernambuco Recife Brazil
2 shared publications - Agna Roberta Xavier Bezerra
Universidade Federal de Pernambuco
1 shared publication
Latest Publications
- Open Access
- 6 October 2026
- Published by Wiley in Journal of Prosthodontics
Effect of different cariostatic agents on the surface roughness and color change of CAD–CAM‐milled restorative materials: An in vitro comparative study
Purpose: To evaluate the influence of different cariostatic agents: 38% silver diamine fluoride (SDF), 38% SDF + potassium iodide (RS), and nano silver fluoride (NSF) compared with distilled water (control), on the surface roughness and color change of CAD–CAM‐milled restorative materials: nanoceramic resin (NR), feldspathic ceramic (FC), and lithium disilicate ceramic (LD). Materials and Methods: Thirty‐two specimens of each material were fabricated and allocated into four experimental groups ( n = 8). The specimens underwent repeated applications of the cariostatic agents (3 min, repeated six times) and were evaluated for surface roughness (∆Ra) by profilometry and for color change using a digital spectrophotometer, with analysis based on the CIEDE2000 system (∆ E 00 ). Data were analyzed using two‐way analysis of variance (ANOVA), followed by one‐way ANOVA or Kruskal–Wallis tests with appropriate post hoc comparisons and Bonferroni correction ( α = 0.05). Results: A statistically significant interaction was observed between restorative material type and the applied cariostatic agent. SDF produced the greatest increases in roughness, especially in LD (∆Ra = 0.232) and FC (∆Ra = 0.126), compared with the control group ( p < 0.001), and color‐change values far above clinically acceptable thresholds (∆ E 00 = 30.56–45.72; p < 0.001). Potassium iodide application after SDF (RS) showed low color change across all restorative materials (∆ E 00 = 0.28–0.75) and increased roughness in the FC. NSF showed behavior similar to the control group in terms of roughness and maintained color‐change values within acceptable limits (∆ E 00 = 0.57–1.35). Conclusions: SDF may compromise the surface roughness and color change of CAD–CAM‐milled restorative materials, whereas NSF and RS show potential as more favorable alternatives for the evaluated outcomes.
- 6 October 2026
- Published by Wiley in Journal of Prosthodontics
Open AccessEffect of different cariostatic agents on the surface roughness and color change of CAD–CAM‐milled restorative materials: An in vitro comparative study
Purpose: To evaluate the influence of different cariostatic agents: 38% silver diamine fluoride (SDF), 38% SDF + potassium iodide (RS), and nano silver fluoride (NSF) compared with distilled water (control), on the surface roughness and color change of CAD–CAM‐milled restorative materials: nanoceramic resin (NR), feldspathic ceramic (FC), and lithium disilicate ceramic (LD). Materials and Methods: Thirty‐two specimens of each material were fabricated and allocated into four experimental groups ( n = 8). The specimens underwent repeated applications of the cariostatic agents (3 min, repeated six times) and were evaluated for surface roughness (∆Ra) by profilometry and for color change using a digital spectrophotometer, with analysis based on the CIEDE2000 system (∆ E 00 ). Data were analyzed using two‐way analysis of variance (ANOVA), followed by one‐way ANOVA or Kruskal–Wallis tests with appropriate post hoc comparisons and Bonferroni correction ( α = 0.05). Results: A statistically significant interaction was observed between restorative material type and the applied cariostatic agent. SDF produced the greatest increases in roughness, especially in LD (∆Ra = 0.232) and FC (∆Ra = 0.126), compared with the control group ( p < 0.001), and color‐change values far above clinically acceptable thresholds (∆ E 00 = 30.56–45.72; p < 0.001). Potassium iodide application after SDF (RS) showed low color change across all restorative materials (∆ E 00 = 0.28–0.75) and increased roughness in the FC. NSF showed behavior similar to the control group in terms of roughness and maintained color‐change values within acceptable limits (∆ E 00 = 0.57–1.35). Conclusions: SDF may compromise the surface roughness and color change of CAD–CAM‐milled restorative materials, whereas NSF and RS show potential as more favorable alternatives for the evaluated outcomes.
- Open Access
Effect of Nano-Silver Fluoride Containing 2000 ppm Silver Nanoparticles on the Microhardness and Color of Flowable Resin Composites: An In Vitro Pilot Study
Although the modification of resin composites with antimicrobial agents represents a viable alternative for biofilm inhibition, these changes may compromise the optical and mechanical properties of dental restorations. This in vitro pilot study evaluated the effect of incorporating Nano-Silver Fluoride (NSF) containing 2000 ppm silver nanoparticles (AgNPs) on the microhardness and color of flowable resin composites: Vittra APS Unique Flowable (VA), Filtek Bulk Fill Flowable (FB), and Filtek Supreme Flowable (FS). The resin composites were modified by adding 1 wt%, 2 wt%, and 4 wt% NSF and compared with an unmodified group (control). NSF was characterized by UV–visible spectroscopy and transmission electron microscopy. The specimens were subjected to Vickers microhardness testing and color analysis using the CIEDE2000 (ΔE00) and CIELAB (ΔE) systems. NSF incorporation had a material-dependent effect on microhardness. The VA group showed a progressive reduction in microhardness with increasing NSF additions, whereas the FS group remained unchanged up to the concentration of 2 wt%, and the FB group showed no significant reduction in microhardness at any of the tested concentrations compared with the control (p = 0.549). All resin composites exhibited clinically relevant color changes that increased with the NSF concentration, with more pronounced color changes in the VA group, whereas FB and FS did not vary significantly with the addition of different NSF concentrations. Overall, NSF mainly affected the optical properties, with esthetic limitations being the main challenge to be overcome in further studies. The FB and FS groups at 1 wt% and 2 wt% showed smaller chromatic changes than VA, without compromising microhardness, and appear promising for future investigations, including antimicrobial and cytotoxicity analyses.
Open AccessEffect of Nano-Silver Fluoride Containing 2000 ppm Silver Nanoparticles on the Microhardness and Color of Flowable Resin Composites: An In Vitro Pilot Study
Although the modification of resin composites with antimicrobial agents represents a viable alternative for biofilm inhibition, these changes may compromise the optical and mechanical properties of dental restorations. This in vitro pilot study evaluated the effect of incorporating Nano-Silver Fluoride (NSF) containing 2000 ppm silver nanoparticles (AgNPs) on the microhardness and color of flowable resin composites: Vittra APS Unique Flowable (VA), Filtek Bulk Fill Flowable (FB), and Filtek Supreme Flowable (FS). The resin composites were modified by adding 1 wt%, 2 wt%, and 4 wt% NSF and compared with an unmodified group (control). NSF was characterized by UV–visible spectroscopy and transmission electron microscopy. The specimens were subjected to Vickers microhardness testing and color analysis using the CIEDE2000 (ΔE00) and CIELAB (ΔE) systems. NSF incorporation had a material-dependent effect on microhardness. The VA group showed a progressive reduction in microhardness with increasing NSF additions, whereas the FS group remained unchanged up to the concentration of 2 wt%, and the FB group showed no significant reduction in microhardness at any of the tested concentrations compared with the control (p = 0.549). All resin composites exhibited clinically relevant color changes that increased with the NSF concentration, with more pronounced color changes in the VA group, whereas FB and FS did not vary significantly with the addition of different NSF concentrations. Overall, NSF mainly affected the optical properties, with esthetic limitations being the main challenge to be overcome in further studies. The FB and FS groups at 1 wt% and 2 wt% showed smaller chromatic changes than VA, without compromising microhardness, and appear promising for future investigations, including antimicrobial and cytotoxicity analyses.
- Open Access
- 15 June 2026
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 13, 460-467
Evaluation of physicomechanical and optical properties of bioactive glass (BAG)-filled resin composites: an in vitro study
Objective: To evaluate the behavior of bioactive glass (BAG)-filled resin composites (Beautifil II / Shofu—BR and Beautifil Flow Plus / Shofu—BF) compared with conventional resin composites (Filtek Z350 XT / Solventum—ZR and Filtek Supreme Flowable Restorative / Solventum—FS) by means of microhardness, sorption, solubility, and color stability tests. Materials and methods: For these analyses, ten specimens were fabricated per group using a split metal mold (15 mm in diameter × 1 mm thickness). Microhardness (n = 10) was measured using a digital microhardness tester, based on the mean of three indentations per specimen under a 2.94 N load for 15 s. For the sorption and solubility tests, five out of the 10 specimens used in the microhardness assays were randomly selected (n = 5), and ISO 4049/2019 recommendations were followed. Color stability was assessed using a digital spectrophotometer by comparing specimens immersed in coffee (using the five specimens not selected for the sorption and solubility tests / n = 5) and distilled water (control, using the same specimens from the sorption and solubility tests), with measurements obtained at baseline, after 1 day, and after 1 week of immersion. Color change (ΔE) was calculated using CIELAB parameters. Results: For microhardness, the high-viscosity resin composites (ZR and BR) showed significantly higher mean values than their low-viscosity versions (p < 0.001). Although sorption differed significantly among groups (p = 0.001), all resin composites exhibited values within the limits established by ISO 4049/2019. No statistically significant differences were observed for solubility. Regarding color stability, after 7 days in coffee, BR and ZR exhibited the greatest color changes (ΔE). Despite the observed statistical differences, the changes remained within acceptable clinical limits. Conclusion: BAG-filled resin composites exhibit properties comparable to those of conventional resin composites. The ZR resin composite showed higher microhardness; however, for the other evaluated parameters (sorption, solubility, and color stability in coffee), the tested resin composites exhibited values within the limits recommended by ISO 4049:2019 and were comparable to those of the reference conventional high- or low-viscosity resin composite.
- 15 June 2026
- Published by Medical Journals Sweden AB in Biomaterial Investigations in Dentistry
- Vol. 13, 460-467
Open AccessEvaluation of physicomechanical and optical properties of bioactive glass (BAG)-filled resin composites: an in vitro study
Objective: To evaluate the behavior of bioactive glass (BAG)-filled resin composites (Beautifil II / Shofu—BR and Beautifil Flow Plus / Shofu—BF) compared with conventional resin composites (Filtek Z350 XT / Solventum—ZR and Filtek Supreme Flowable Restorative / Solventum—FS) by means of microhardness, sorption, solubility, and color stability tests. Materials and methods: For these analyses, ten specimens were fabricated per group using a split metal mold (15 mm in diameter × 1 mm thickness). Microhardness (n = 10) was measured using a digital microhardness tester, based on the mean of three indentations per specimen under a 2.94 N load for 15 s. For the sorption and solubility tests, five out of the 10 specimens used in the microhardness assays were randomly selected (n = 5), and ISO 4049/2019 recommendations were followed. Color stability was assessed using a digital spectrophotometer by comparing specimens immersed in coffee (using the five specimens not selected for the sorption and solubility tests / n = 5) and distilled water (control, using the same specimens from the sorption and solubility tests), with measurements obtained at baseline, after 1 day, and after 1 week of immersion. Color change (ΔE) was calculated using CIELAB parameters. Results: For microhardness, the high-viscosity resin composites (ZR and BR) showed significantly higher mean values than their low-viscosity versions (p < 0.001). Although sorption differed significantly among groups (p = 0.001), all resin composites exhibited values within the limits established by ISO 4049/2019. No statistically significant differences were observed for solubility. Regarding color stability, after 7 days in coffee, BR and ZR exhibited the greatest color changes (ΔE). Despite the observed statistical differences, the changes remained within acceptable clinical limits. Conclusion: BAG-filled resin composites exhibit properties comparable to those of conventional resin composites. The ZR resin composite showed higher microhardness; however, for the other evaluated parameters (sorption, solubility, and color stability in coffee), the tested resin composites exhibited values within the limits recommended by ISO 4049:2019 and were comparable to those of the reference conventional high- or low-viscosity resin composite.
- Open Access
- 8 March 2026
- Published by Wiley in European Journal of Oral Sciences
- Vol. 134 (4) , e70081
Evaluation of physical, chemical, and color‐matching properties of monochromatic resin composites: An in vitro study
The objectives of this study are to evaluate, in vitro, the microhardness, sorption, solubility, color stability, and color‐matching ability of monochromatic resin composites: Palfique Omnichroma / Tokuyama (Mono1) and Vittra APS Unique / FGM (Mono2) compared with the conventional resin composite: Filtek Z250 XT / Solventum (Conv). For this analysis, ten disc‐shaped composite specimens were prepared for each group for the microhardness, sorption, solubility, and color stability tests. To evaluate color‐matching ability, 36 tooth specimens were obtained from the buccal/lingual surfaces of human molars ( n = 12). The teeth were restored, and color compatibility was assessed with a digital spectrophotometer (Vita Easy Shade) and visually. Microhardness and sorption were higher in the Conv group. However, sorption values are within the limits established by ISO 4049/2019 for all groups. No significant difference in solubility or visual color match was noted. However, the conv group demonstrated superior color‐matching in the spectrophotometer analysis. After 7 days of coffee immersion, the Mono 1 group showed slightly less pigmentation. Monochromatic resin composites demonstrated physicochemical and organoleptic properties comparable to those of the evaluated conventional resin composites, suggesting similar compatibility and a potential option for simplifying clinical restorative protocols.
- 8 March 2026
- Published by Wiley in European Journal of Oral Sciences
- Vol. 134 (4) , e70081
Open AccessEvaluation of physical, chemical, and color‐matching properties of monochromatic resin composites: An in vitro study
The objectives of this study are to evaluate, in vitro, the microhardness, sorption, solubility, color stability, and color‐matching ability of monochromatic resin composites: Palfique Omnichroma / Tokuyama (Mono1) and Vittra APS Unique / FGM (Mono2) compared with the conventional resin composite: Filtek Z250 XT / Solventum (Conv). For this analysis, ten disc‐shaped composite specimens were prepared for each group for the microhardness, sorption, solubility, and color stability tests. To evaluate color‐matching ability, 36 tooth specimens were obtained from the buccal/lingual surfaces of human molars ( n = 12). The teeth were restored, and color compatibility was assessed with a digital spectrophotometer (Vita Easy Shade) and visually. Microhardness and sorption were higher in the Conv group. However, sorption values are within the limits established by ISO 4049/2019 for all groups. No significant difference in solubility or visual color match was noted. However, the conv group demonstrated superior color‐matching in the spectrophotometer analysis. After 7 days of coffee immersion, the Mono 1 group showed slightly less pigmentation. Monochromatic resin composites demonstrated physicochemical and organoleptic properties comparable to those of the evaluated conventional resin composites, suggesting similar compatibility and a potential option for simplifying clinical restorative protocols.
- Open Access
- 24 December 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (4) , 874-882
Fracture Resistance of Extensively Compromised Anterior Teeth Restored With Fiberglass Posts and Biomimetic Protocols: An In Vitro Study
Objective: Polyethylene fiber (PF) and fiberglass (FG) posts have been recommended for intraradicular anchorage when there is a significant loss of coronal structure. However, few studies have evaluated their performance in anterior teeth combined with direct restorations as an alternative to single crowns. The objective of this study is to compare the fracture resistance and failure modes of endodontically treated anterior teeth restored with a FG post, a biomimetic technique using PF, and a direct resin composite (RC). Materials and Methods: Forty sound upper central incisors were selected, endodontically treated, standardized for clinical crown height, and randomly distributed into four groups ( n = 10): Positive control: teeth with an intact clinical crown, subjected only to access and endodontic treatment (CT), RC, PF, and FG post. Restorations were performed according to specific clinical protocols using a universal adhesive system. Fracture resistance was tested on a universal testing machine under compressive load at a 45° angle (1 mm/min). Fracture patterns were analyzed under a stereomicroscope and classified as either repairable or catastrophic. Data were analyzed using ANOVA and Fisher's exact test ( α = 0.05). Results: The CT group exhibited the highest mean resistance (840 N), followed by PF (740 N), FG (700 N), and RC (480 N), with a significant difference between the RC group and the others ( p < 0.001). No significant difference was found among the groups regarding the failure mode ( p > 0.05). Conclusion: FGs and PFs provided greater fracture resistance and a higher incidence of repairable fractures, with more favorable outcomes than when the procedure is performed exclusively with RC restorations.
- 24 December 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 38 (4) , 874-882
Open AccessFracture Resistance of Extensively Compromised Anterior Teeth Restored With Fiberglass Posts and Biomimetic Protocols: An In Vitro Study
Objective: Polyethylene fiber (PF) and fiberglass (FG) posts have been recommended for intraradicular anchorage when there is a significant loss of coronal structure. However, few studies have evaluated their performance in anterior teeth combined with direct restorations as an alternative to single crowns. The objective of this study is to compare the fracture resistance and failure modes of endodontically treated anterior teeth restored with a FG post, a biomimetic technique using PF, and a direct resin composite (RC). Materials and Methods: Forty sound upper central incisors were selected, endodontically treated, standardized for clinical crown height, and randomly distributed into four groups ( n = 10): Positive control: teeth with an intact clinical crown, subjected only to access and endodontic treatment (CT), RC, PF, and FG post. Restorations were performed according to specific clinical protocols using a universal adhesive system. Fracture resistance was tested on a universal testing machine under compressive load at a 45° angle (1 mm/min). Fracture patterns were analyzed under a stereomicroscope and classified as either repairable or catastrophic. Data were analyzed using ANOVA and Fisher's exact test ( α = 0.05). Results: The CT group exhibited the highest mean resistance (840 N), followed by PF (740 N), FG (700 N), and RC (480 N), with a significant difference between the RC group and the others ( p < 0.001). No significant difference was found among the groups regarding the failure mode ( p > 0.05). Conclusion: FGs and PFs provided greater fracture resistance and a higher incidence of repairable fractures, with more favorable outcomes than when the procedure is performed exclusively with RC restorations.