Shuangxi He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuangxi He has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jieyu Cao
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
2 shared publications Jun Hu
Department of Cardiothoracic Surgery, The Second Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
2 shared publications- Zhengwen Lei
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
2 shared publications Chaozhong Long
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
1 shared publication- Haoshi Wang
School of Nursing, University of South China, 421001 Hengyang, Hunan, China
1 shared publication Heng Yang
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 27 (6) , 49740
Comparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion
Background:To compare the early efficacy of an integrated stent-graft (16-cm covered stent combined with a 6-cm distal bare stent) versus a conventional covered stent-graft alone in patients with acute type B aortic dissection (TBAD), with a focus on aortic remodeling and branch artery perfusion.Methods:In this single-center retrospective cohort study, 102 patients were included (integrated stent-graft: n = 34; conventional stent-graft: n = 68). Aortic remodeling was assessed using the true lumen area ratio at five predefined anatomical planes. Branch artery perfusion patterns and procedure-related complications were evaluated preoperatively and at 3-month follow-up.Results:At 3 months, the integrated stent-graft group demonstrated significantly higher true lumen area ratios at the left subclavian artery plane 0.60 (0.41, 0.63) vs. 0.41 (0.25, 0.54), p = 0.002; pulmonary artery plane 0.65 (0.54, 0.71) vs. 0.44 (0.38, 0.53), p < 0.001; and diaphragmatic plane 0.61 (0.50, 0.76) vs. 0.44 (0.37, 0.51), p < 0.001. No significant differences were observed at the renal or iliac planes. Regarding branch perfusion, a significant overall difference in postoperative perfusion pattern distribution was observed for the celiac trunk (p = 0.027) and left renal artery (p = 0.017). No differences were detected in other branch arteries. The incidence of postoperative new entry tears was lower in the integrated stent-graft group (23.5% vs. 41.2%), although this difference did not reach statistical significance (p = 0.079).Conclusions:In this exploratory retrospective study with short-term (3-month) follow-up, the integrated stent-graft system was associated with improved early true lumen remodeling in the proximal and mid-aortic segments and differences in branch artery perfusion patterns compared with a conventional covered stent-graft alone. A trend toward fewer new entry tears was observed, but given the limited follow-up and sample size, these findings should be considered preliminary. Confirmation in larger prospective studies with long-term follow-up is warranted to determine whether these early imaging changes translate into durable clinical benefit.
- 24 June 2026
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 27 (6) , 49740
Open AccessComparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion
Background:To compare the early efficacy of an integrated stent-graft (16-cm covered stent combined with a 6-cm distal bare stent) versus a conventional covered stent-graft alone in patients with acute type B aortic dissection (TBAD), with a focus on aortic remodeling and branch artery perfusion.Methods:In this single-center retrospective cohort study, 102 patients were included (integrated stent-graft: n = 34; conventional stent-graft: n = 68). Aortic remodeling was assessed using the true lumen area ratio at five predefined anatomical planes. Branch artery perfusion patterns and procedure-related complications were evaluated preoperatively and at 3-month follow-up.Results:At 3 months, the integrated stent-graft group demonstrated significantly higher true lumen area ratios at the left subclavian artery plane 0.60 (0.41, 0.63) vs. 0.41 (0.25, 0.54), p = 0.002; pulmonary artery plane 0.65 (0.54, 0.71) vs. 0.44 (0.38, 0.53), p < 0.001; and diaphragmatic plane 0.61 (0.50, 0.76) vs. 0.44 (0.37, 0.51), p < 0.001. No significant differences were observed at the renal or iliac planes. Regarding branch perfusion, a significant overall difference in postoperative perfusion pattern distribution was observed for the celiac trunk (p = 0.027) and left renal artery (p = 0.017). No differences were detected in other branch arteries. The incidence of postoperative new entry tears was lower in the integrated stent-graft group (23.5% vs. 41.2%), although this difference did not reach statistical significance (p = 0.079).Conclusions:In this exploratory retrospective study with short-term (3-month) follow-up, the integrated stent-graft system was associated with improved early true lumen remodeling in the proximal and mid-aortic segments and differences in branch artery perfusion patterns compared with a conventional covered stent-graft alone. A trend toward fewer new entry tears was observed, but given the limited follow-up and sample size, these findings should be considered preliminary. Confirmation in larger prospective studies with long-term follow-up is warranted to determine whether these early imaging changes translate into durable clinical benefit.
- Open Access
- 16 March 2026
- Published by IMR Press in The Heart Surgery Forum
- Vol. 29 (3)
Surgical Approaches for Heart Transplantation in Cardiomyopathy Patients: Current Trends
Heart transplantation (HT) remains the only therapeutic option that significantly improves long-term survival for patients with end-stage cardiomyopathy. However, clinical practice faces challenges including the shortage of donor organs, increased surgical risks, and limitations in long-term survival. Recent advancements in minimally invasive surgery, precision immunosuppression, xenotransplantation, and artificial heart technologies have substantially improved transplant safety and outcomes; however, a systematic integration of these innovations is lacking. This study reviews technological advancements and current trends in HT to optimize clinical decision-making and promote individualized treatment strategies. A systematic review of literature published between 2015 and 2025 was conducted using PubMed and Web of Science databases. The search focused on five key areas of HT: minimally invasive surgery, donor expansion, precision immunosuppression, xenotransplantation, and postoperative management. Literature screening and analysis were performed independently by two researchers to ensure the objectivity and accuracy of the findings. Minimally invasive techniques, including partial Maryland and robot-assisted surgery, have significantly reduced postoperative bleeding and complications in high-risk patients. Normothermic machine perfusion (NMP) has extended donor heart preservation up to 12 hours, improving marginal donor utilization. Genotype-guided immunosuppressive therapy and donor-derived cell-free DNA (dd-cfDNA) monitoring enhance the precision of immunosuppression management. CRISPR-Cas9-mediated xenotransplantation has enabled successful transplantation of genetically modified pig hearts into humans, with reported survival exceeding 60 days. Magnetic Resonance Imaging (MRI) T1/T2 mapping and implantable hemodynamic monitoring technologies also show promise for the non-invasive early detection of rejection. Technological innovations have greatly enhanced clinical outcomes in HT. However, further long-term data and standardized evidence are necessary. Future efforts should focus on standardizing techniques, translating immune tolerance strategies into clinical practice, and establishing safety frameworks for xenotransplantation.
- 16 March 2026
- Published by IMR Press in The Heart Surgery Forum
- Vol. 29 (3)
Open AccessSurgical Approaches for Heart Transplantation in Cardiomyopathy Patients: Current Trends
Heart transplantation (HT) remains the only therapeutic option that significantly improves long-term survival for patients with end-stage cardiomyopathy. However, clinical practice faces challenges including the shortage of donor organs, increased surgical risks, and limitations in long-term survival. Recent advancements in minimally invasive surgery, precision immunosuppression, xenotransplantation, and artificial heart technologies have substantially improved transplant safety and outcomes; however, a systematic integration of these innovations is lacking. This study reviews technological advancements and current trends in HT to optimize clinical decision-making and promote individualized treatment strategies. A systematic review of literature published between 2015 and 2025 was conducted using PubMed and Web of Science databases. The search focused on five key areas of HT: minimally invasive surgery, donor expansion, precision immunosuppression, xenotransplantation, and postoperative management. Literature screening and analysis were performed independently by two researchers to ensure the objectivity and accuracy of the findings. Minimally invasive techniques, including partial Maryland and robot-assisted surgery, have significantly reduced postoperative bleeding and complications in high-risk patients. Normothermic machine perfusion (NMP) has extended donor heart preservation up to 12 hours, improving marginal donor utilization. Genotype-guided immunosuppressive therapy and donor-derived cell-free DNA (dd-cfDNA) monitoring enhance the precision of immunosuppression management. CRISPR-Cas9-mediated xenotransplantation has enabled successful transplantation of genetically modified pig hearts into humans, with reported survival exceeding 60 days. Magnetic Resonance Imaging (MRI) T1/T2 mapping and implantable hemodynamic monitoring technologies also show promise for the non-invasive early detection of rejection. Technological innovations have greatly enhanced clinical outcomes in HT. However, further long-term data and standardized evidence are necessary. Future efforts should focus on standardizing techniques, translating immune tolerance strategies into clinical practice, and establishing safety frameworks for xenotransplantation.
- Open Access
- 19 December 2025
- Published by IMR Press in The Heart Surgery Forum
- Vol. 28 (12)
Preliminary Results of the Non-Free Left Subclavian Artery and Single-Branch Stent Graft Technique in the Treatment of Acute DeBakey Type I Aortic Dissection
Background: This study aimed to explore the clinical advantages of the non-free left subclavian artery and single-branch stent graft technique in treating acute DeBakey Type I aortic dissection, with a focus on evaluating the impact of the technique on intraoperative efficiency, postoperative complications, and prognosis. Methods: This study retrospectively analyzed 58 patients with acute DeBakey type I aortic dissection admitted between August 2023 and October 2024. All enrolled patients underwent ascending aorta replacement in combination with total aortic arch replacement and descending aortic stent graft implantation. In the experimental group (n = 28), the left subclavian artery (LSA) was reconstructed using branched stent grafts for distal descending aortic repair, maintaining the anatomical integrity of the vessel and deliberately preserving the thoracic duct and recurrent laryngeal nerve. In the control group (n = 30), conventional minimally invasive stent reconstruction was employed for distal descending aortic repair with anatomical isolation of the LSA. Statistical analyses were conducted on intraoperative parameters (total operative time, heparinization duration), complications (chylothorax, hoarseness), and prognostic indicators (duration of tracheal intubation, mortality rate) using SPSS, version 26.0.0.0 (IBM Corp., Armonk, NY, USA), after controlling for preoperative baseline characteristics between groups. Results: The total surgical time in the experimental group was significantly shorter than that in the control group (256.21 ± 53.08 minutes vs. 298.97 ± 51.09 minutes; p = 0.003). The intensive care unit (ICU) length of stay (159.50 minutes vs. 257.00 minutes; p < 0.001) and postoperative hospital stay duration (14.00 days vs. 21.00 days; p = 0.001) were also shorter in the experimental group. There was no significant difference in mortality (28.57% vs. 10.00%; p = 0.071) and rethoracotomy rates (10.71% vs. 10.00%; p = 0.732) between the two groups. No cases of recurrent laryngeal nerve injury or chylothorax occurred in the experimental group, whereas the control group reported a 6.67% incidence of chylothorax and 10.00% noted hoarseness. Conclusion: The non-free left subclavian artery and single-branch stent graft technique can significantly shorten surgical time and reduce postoperative drainage volume and ICU stay duration. Additionally, no recurrent laryngeal nerve injury or chylothorax was observed in this group. Thus, this technique represents a safe and effective surgical approach for acute DeBakey Type I aortic dissection.
- 19 December 2025
- Published by IMR Press in The Heart Surgery Forum
- Vol. 28 (12)
Open AccessPreliminary Results of the Non-Free Left Subclavian Artery and Single-Branch Stent Graft Technique in the Treatment of Acute DeBakey Type I Aortic Dissection
Background: This study aimed to explore the clinical advantages of the non-free left subclavian artery and single-branch stent graft technique in treating acute DeBakey Type I aortic dissection, with a focus on evaluating the impact of the technique on intraoperative efficiency, postoperative complications, and prognosis. Methods: This study retrospectively analyzed 58 patients with acute DeBakey type I aortic dissection admitted between August 2023 and October 2024. All enrolled patients underwent ascending aorta replacement in combination with total aortic arch replacement and descending aortic stent graft implantation. In the experimental group (n = 28), the left subclavian artery (LSA) was reconstructed using branched stent grafts for distal descending aortic repair, maintaining the anatomical integrity of the vessel and deliberately preserving the thoracic duct and recurrent laryngeal nerve. In the control group (n = 30), conventional minimally invasive stent reconstruction was employed for distal descending aortic repair with anatomical isolation of the LSA. Statistical analyses were conducted on intraoperative parameters (total operative time, heparinization duration), complications (chylothorax, hoarseness), and prognostic indicators (duration of tracheal intubation, mortality rate) using SPSS, version 26.0.0.0 (IBM Corp., Armonk, NY, USA), after controlling for preoperative baseline characteristics between groups. Results: The total surgical time in the experimental group was significantly shorter than that in the control group (256.21 ± 53.08 minutes vs. 298.97 ± 51.09 minutes; p = 0.003). The intensive care unit (ICU) length of stay (159.50 minutes vs. 257.00 minutes; p < 0.001) and postoperative hospital stay duration (14.00 days vs. 21.00 days; p = 0.001) were also shorter in the experimental group. There was no significant difference in mortality (28.57% vs. 10.00%; p = 0.071) and rethoracotomy rates (10.71% vs. 10.00%; p = 0.732) between the two groups. No cases of recurrent laryngeal nerve injury or chylothorax occurred in the experimental group, whereas the control group reported a 6.67% incidence of chylothorax and 10.00% noted hoarseness. Conclusion: The non-free left subclavian artery and single-branch stent graft technique can significantly shorten surgical time and reduce postoperative drainage volume and ICU stay duration. Additionally, no recurrent laryngeal nerve injury or chylothorax was observed in this group. Thus, this technique represents a safe and effective surgical approach for acute DeBakey Type I aortic dissection.