Jieyu Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jieyu Cao has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Shuangxi He
Department of Cardiothoracic Surgery, The Second Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
2 shared publications - Zhengwen Lei
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
2 shared publications Chaozhong Long
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
1 shared publication- Haoshi Wang
School of Nursing, University of South China, 421001 Hengyang, Hunan, China
1 shared publication Heng Yang
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
1 shared publication- Juan Luo
Department of Cardiothoracic Surgery, The First Affiliated Hospital, Hengyang Medical School, University of South China, 421001 Hengyang, Hunan, China
1 shared publication
Latest Publications
- Open Access
- 24 June 2026
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 27 (6) , 49740
Comparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion
Background:To compare the early efficacy of an integrated stent-graft (16-cm covered stent combined with a 6-cm distal bare stent) versus a conventional covered stent-graft alone in patients with acute type B aortic dissection (TBAD), with a focus on aortic remodeling and branch artery perfusion.Methods:In this single-center retrospective cohort study, 102 patients were included (integrated stent-graft: n = 34; conventional stent-graft: n = 68). Aortic remodeling was assessed using the true lumen area ratio at five predefined anatomical planes. Branch artery perfusion patterns and procedure-related complications were evaluated preoperatively and at 3-month follow-up.Results:At 3 months, the integrated stent-graft group demonstrated significantly higher true lumen area ratios at the left subclavian artery plane 0.60 (0.41, 0.63) vs. 0.41 (0.25, 0.54), p = 0.002; pulmonary artery plane 0.65 (0.54, 0.71) vs. 0.44 (0.38, 0.53), p < 0.001; and diaphragmatic plane 0.61 (0.50, 0.76) vs. 0.44 (0.37, 0.51), p < 0.001. No significant differences were observed at the renal or iliac planes. Regarding branch perfusion, a significant overall difference in postoperative perfusion pattern distribution was observed for the celiac trunk (p = 0.027) and left renal artery (p = 0.017). No differences were detected in other branch arteries. The incidence of postoperative new entry tears was lower in the integrated stent-graft group (23.5% vs. 41.2%), although this difference did not reach statistical significance (p = 0.079).Conclusions:In this exploratory retrospective study with short-term (3-month) follow-up, the integrated stent-graft system was associated with improved early true lumen remodeling in the proximal and mid-aortic segments and differences in branch artery perfusion patterns compared with a conventional covered stent-graft alone. A trend toward fewer new entry tears was observed, but given the limited follow-up and sample size, these findings should be considered preliminary. Confirmation in larger prospective studies with long-term follow-up is warranted to determine whether these early imaging changes translate into durable clinical benefit.
- 24 June 2026
- Published by IMR Press in Reviews in Cardiovascular Medicine
- Vol. 27 (6) , 49740
Open AccessComparative Efficacy of Integrated Stent-Graft versus Conventional Covered Stent-Graft Alone in Type B Aortic Dissection: A Retrospective Study Focusing on Aortic Remodeling and Branch Perfusion
Background:To compare the early efficacy of an integrated stent-graft (16-cm covered stent combined with a 6-cm distal bare stent) versus a conventional covered stent-graft alone in patients with acute type B aortic dissection (TBAD), with a focus on aortic remodeling and branch artery perfusion.Methods:In this single-center retrospective cohort study, 102 patients were included (integrated stent-graft: n = 34; conventional stent-graft: n = 68). Aortic remodeling was assessed using the true lumen area ratio at five predefined anatomical planes. Branch artery perfusion patterns and procedure-related complications were evaluated preoperatively and at 3-month follow-up.Results:At 3 months, the integrated stent-graft group demonstrated significantly higher true lumen area ratios at the left subclavian artery plane 0.60 (0.41, 0.63) vs. 0.41 (0.25, 0.54), p = 0.002; pulmonary artery plane 0.65 (0.54, 0.71) vs. 0.44 (0.38, 0.53), p < 0.001; and diaphragmatic plane 0.61 (0.50, 0.76) vs. 0.44 (0.37, 0.51), p < 0.001. No significant differences were observed at the renal or iliac planes. Regarding branch perfusion, a significant overall difference in postoperative perfusion pattern distribution was observed for the celiac trunk (p = 0.027) and left renal artery (p = 0.017). No differences were detected in other branch arteries. The incidence of postoperative new entry tears was lower in the integrated stent-graft group (23.5% vs. 41.2%), although this difference did not reach statistical significance (p = 0.079).Conclusions:In this exploratory retrospective study with short-term (3-month) follow-up, the integrated stent-graft system was associated with improved early true lumen remodeling in the proximal and mid-aortic segments and differences in branch artery perfusion patterns compared with a conventional covered stent-graft alone. A trend toward fewer new entry tears was observed, but given the limited follow-up and sample size, these findings should be considered preliminary. Confirmation in larger prospective studies with long-term follow-up is warranted to determine whether these early imaging changes translate into durable clinical benefit.
- Open Access
- 16 March 2026
- Published by IMR Press in The Heart Surgery Forum
- Vol. 29 (3)
Surgical Approaches for Heart Transplantation in Cardiomyopathy Patients: Current Trends
Heart transplantation (HT) remains the only therapeutic option that significantly improves long-term survival for patients with end-stage cardiomyopathy. However, clinical practice faces challenges including the shortage of donor organs, increased surgical risks, and limitations in long-term survival. Recent advancements in minimally invasive surgery, precision immunosuppression, xenotransplantation, and artificial heart technologies have substantially improved transplant safety and outcomes; however, a systematic integration of these innovations is lacking. This study reviews technological advancements and current trends in HT to optimize clinical decision-making and promote individualized treatment strategies. A systematic review of literature published between 2015 and 2025 was conducted using PubMed and Web of Science databases. The search focused on five key areas of HT: minimally invasive surgery, donor expansion, precision immunosuppression, xenotransplantation, and postoperative management. Literature screening and analysis were performed independently by two researchers to ensure the objectivity and accuracy of the findings. Minimally invasive techniques, including partial Maryland and robot-assisted surgery, have significantly reduced postoperative bleeding and complications in high-risk patients. Normothermic machine perfusion (NMP) has extended donor heart preservation up to 12 hours, improving marginal donor utilization. Genotype-guided immunosuppressive therapy and donor-derived cell-free DNA (dd-cfDNA) monitoring enhance the precision of immunosuppression management. CRISPR-Cas9-mediated xenotransplantation has enabled successful transplantation of genetically modified pig hearts into humans, with reported survival exceeding 60 days. Magnetic Resonance Imaging (MRI) T1/T2 mapping and implantable hemodynamic monitoring technologies also show promise for the non-invasive early detection of rejection. Technological innovations have greatly enhanced clinical outcomes in HT. However, further long-term data and standardized evidence are necessary. Future efforts should focus on standardizing techniques, translating immune tolerance strategies into clinical practice, and establishing safety frameworks for xenotransplantation.
- 16 March 2026
- Published by IMR Press in The Heart Surgery Forum
- Vol. 29 (3)
Open AccessSurgical Approaches for Heart Transplantation in Cardiomyopathy Patients: Current Trends
Heart transplantation (HT) remains the only therapeutic option that significantly improves long-term survival for patients with end-stage cardiomyopathy. However, clinical practice faces challenges including the shortage of donor organs, increased surgical risks, and limitations in long-term survival. Recent advancements in minimally invasive surgery, precision immunosuppression, xenotransplantation, and artificial heart technologies have substantially improved transplant safety and outcomes; however, a systematic integration of these innovations is lacking. This study reviews technological advancements and current trends in HT to optimize clinical decision-making and promote individualized treatment strategies. A systematic review of literature published between 2015 and 2025 was conducted using PubMed and Web of Science databases. The search focused on five key areas of HT: minimally invasive surgery, donor expansion, precision immunosuppression, xenotransplantation, and postoperative management. Literature screening and analysis were performed independently by two researchers to ensure the objectivity and accuracy of the findings. Minimally invasive techniques, including partial Maryland and robot-assisted surgery, have significantly reduced postoperative bleeding and complications in high-risk patients. Normothermic machine perfusion (NMP) has extended donor heart preservation up to 12 hours, improving marginal donor utilization. Genotype-guided immunosuppressive therapy and donor-derived cell-free DNA (dd-cfDNA) monitoring enhance the precision of immunosuppression management. CRISPR-Cas9-mediated xenotransplantation has enabled successful transplantation of genetically modified pig hearts into humans, with reported survival exceeding 60 days. Magnetic Resonance Imaging (MRI) T1/T2 mapping and implantable hemodynamic monitoring technologies also show promise for the non-invasive early detection of rejection. Technological innovations have greatly enhanced clinical outcomes in HT. However, further long-term data and standardized evidence are necessary. Future efforts should focus on standardizing techniques, translating immune tolerance strategies into clinical practice, and establishing safety frameworks for xenotransplantation.