Zining Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zining Guo has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Hongwei Liang
Dalian University of Technology
2 shared publications Hongyun Wang
Dalian University of Technology
2 shared publicationsShengyi Hao
Dalian University of Technology
2 shared publicationsWuqi Chen
Dalian University of Technology
2 shared publications- Xiaochuan Xia
Dalian University of Technology
2 shared publications Yuhao Xie
Dalian University of Technology
2 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27238-27244
A Localization Method for Alpha Particle 1-D Position in Diamond Detectors
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (18) , 27238-27244
A Localization Method for Alpha Particle 1-D Position in Diamond Detectors
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (1) , 1248-1254
Multiphysics Modeling of Temperature- Dependent Transient Signals in Diamond Thermal Neutron Detectors
Diamond has emerged as an ideal material for thermal neutron detectors in high-temperature radiation environments due to its low atomic number, high displacement threshold energy, and excellent electron mobility. However, the temperature-dependent degradation mechanisms of its transient signals remain to be fully elucidated. This study proposes a multi-physics coupled simulation approach that integrates SRIM, TCAD, and Garfield++ to investigate the performance evolution of planar and trench-type diamond thermal neutron detectors over a temperature range of 300–700 K. Results show a clear correlation between temperature rise and signal degradation. For planar detectors, increasing temperature leads to reduced carrier mobility and enhanced lateral diffusion, causing a marked decrease in signal amplitude and a broadening of the signal time width. The signal amplitude undergoes a 50% reduction at 400 K and continues to decline to approximately 33% at 700 K, indicative of a substantial loss in detection capability. In trench-type detectors, the distinctive structural configuration results in enhanced sensitivity to temperature, where the current density diminishes and local electric field gradients are alleviated at elevated temperatures. The combined effect of these phenomena is to exacerbate charge dispersion and temporal signal broadening. The study elucidates a comprehensive degradation mechanism driven by temperature-induced changes in carrier transport properties and establishes a quantitative relationship between structural features, thermal effects, and signal behavior. These findings provide critical guidance for designing and optimizing diamond-based thermal neutron detectors in extreme environments.
- 24 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (1) , 1248-1254
Multiphysics Modeling of Temperature- Dependent Transient Signals in Diamond Thermal Neutron Detectors
Diamond has emerged as an ideal material for thermal neutron detectors in high-temperature radiation environments due to its low atomic number, high displacement threshold energy, and excellent electron mobility. However, the temperature-dependent degradation mechanisms of its transient signals remain to be fully elucidated. This study proposes a multi-physics coupled simulation approach that integrates SRIM, TCAD, and Garfield++ to investigate the performance evolution of planar and trench-type diamond thermal neutron detectors over a temperature range of 300–700 K. Results show a clear correlation between temperature rise and signal degradation. For planar detectors, increasing temperature leads to reduced carrier mobility and enhanced lateral diffusion, causing a marked decrease in signal amplitude and a broadening of the signal time width. The signal amplitude undergoes a 50% reduction at 400 K and continues to decline to approximately 33% at 700 K, indicative of a substantial loss in detection capability. In trench-type detectors, the distinctive structural configuration results in enhanced sensitivity to temperature, where the current density diminishes and local electric field gradients are alleviated at elevated temperatures. The combined effect of these phenomena is to exacerbate charge dispersion and temporal signal broadening. The study elucidates a comprehensive degradation mechanism driven by temperature-induced changes in carrier transport properties and establishes a quantitative relationship between structural features, thermal effects, and signal behavior. These findings provide critical guidance for designing and optimizing diamond-based thermal neutron detectors in extreme environments.