- Lujia Wang
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China
2 shared publications - Hailong Zhang
State Grid Jiangsu Electric Power Co., Ltd., Fengxian County Power Supply Branch, Xuzhou 221700, China
1 shared publication - Haitao Yang
Electric Power Research Institute, State Grid Anhui Electric Power Co., Ltd., Hefei 230601, China
1 shared publication - Jie Wu
Electric Power Research Institute, State Grid Anhui Electric Power Co., Ltd., Hefei 230601, China
1 shared publication - Tian Tian
Electric Power Research Institute, State Grid Ningxia Electric Power Co., Ltd., State Grid Corporation of China, Yinchuan 750002, China
1 shared publication - Xingwang Wu
Electric Power Research Institute, State Grid Anhui Electric Power Co., Ltd., Hefei 230601, China
1 shared publication
Latest Publications
- Open Access
- 24 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3793
Duality-Derived Electromagnetic Modeling of an On-Board Traction Transformer Under Power-Frequency Overexcitation
Power-frequency overexcitation increases the voltage-to-frequency ratio applied to a transformer core and may drive the core into saturation, resulting in substantial distortion of the no-load current. This paper presents a duality-derived electromagnetic model for an on-board traction transformer by combining a sixth-order Foster network identified through vector fitting with a Jiles–Atherton hysteresis operator. The proposed model preserves the physical correspondence between magnetic-flux paths and equivalent-circuit elements while accounting for history-dependent core hysteresis and frequency-dependent core impedance. The model is implemented and numerically evaluated in MATLAB/Simulink R2024a, and experimental validation is performed on a 250 kVA prototype under rated power-frequency excitation and power-frequency overexcitation. Under rated excitation, the RMS relative error and NRMSE of the no-load current are 0.09% and 0.96%, respectively, with a maximum relative error of 2.90%. Under power-frequency overexcitation, the NRMSE is 4.14% and the maximum relative error is 9.37%. The results show that the proposed model accurately reproduces the nonlinear no-load current response associated with core saturation and hysteresis within the investigated power-frequency excitation range.
- 24 August 2026
- Published by MDPI AG in Electronics
- Vol. 15 (17) , 3793
Open AccessDuality-Derived Electromagnetic Modeling of an On-Board Traction Transformer Under Power-Frequency Overexcitation
Power-frequency overexcitation increases the voltage-to-frequency ratio applied to a transformer core and may drive the core into saturation, resulting in substantial distortion of the no-load current. This paper presents a duality-derived electromagnetic model for an on-board traction transformer by combining a sixth-order Foster network identified through vector fitting with a Jiles–Atherton hysteresis operator. The proposed model preserves the physical correspondence between magnetic-flux paths and equivalent-circuit elements while accounting for history-dependent core hysteresis and frequency-dependent core impedance. The model is implemented and numerically evaluated in MATLAB/Simulink R2024a, and experimental validation is performed on a 250 kVA prototype under rated power-frequency excitation and power-frequency overexcitation. Under rated excitation, the RMS relative error and NRMSE of the no-load current are 0.09% and 0.96%, respectively, with a maximum relative error of 2.90%. Under power-frequency overexcitation, the NRMSE is 4.14% and the maximum relative error is 9.37%. The results show that the proposed model accurately reproduces the nonlinear no-load current response associated with core saturation and hysteresis within the investigated power-frequency excitation range.
- Open Access
Simulation Study on Anti-Interference Performance Degradation of GIS UHF Sensors Based on Substation White Noise Reconstruction
The ultra-high frequency (UHF)-based partial discharge (PD) detection technology for gas-insulated switchgear (GIS) has achieved large-scale applications due to its high sensitivity and real-time monitoring capabilities. However, long-term service-induced antenna corrosion in UHF sensors may lead to degraded reception characteristics. To ensure the credibility of monitoring data, on-site sensor calibration under ambient noise conditions is required. This study first analyzes the time–frequency domain characteristics of white noise received by UHF sensors in GIS environments. Leveraging the transceiver reciprocity principle of sensors, a noise reconstruction method based on external sensors is proposed to simulate on-site white noise. Subsequently, CST simulation models are established for both standard and degraded sensors, quantifying the impact of factors like antenna corrosion on performance parameters such as echo impedance S11 and voltage standing wave ratio (VSWR). Finally, the two sensor models are coupled into GIS handholes for comparative simulation analysis. Results show that antenna corrosion causes resonant frequency shifts in sensors, reducing PD signal power by 55.27% and increasing noise power by 64.11%. The signal-to-noise ratio (SNR) decreases from −9.70 dB to −15.34 dB, with evident waveform distortion in the double-exponential PD pulses. These conclusions provide theoretical references for on-site UHF sensor calibration in noisy environments.
Open AccessSimulation Study on Anti-Interference Performance Degradation of GIS UHF Sensors Based on Substation White Noise Reconstruction
The ultra-high frequency (UHF)-based partial discharge (PD) detection technology for gas-insulated switchgear (GIS) has achieved large-scale applications due to its high sensitivity and real-time monitoring capabilities. However, long-term service-induced antenna corrosion in UHF sensors may lead to degraded reception characteristics. To ensure the credibility of monitoring data, on-site sensor calibration under ambient noise conditions is required. This study first analyzes the time–frequency domain characteristics of white noise received by UHF sensors in GIS environments. Leveraging the transceiver reciprocity principle of sensors, a noise reconstruction method based on external sensors is proposed to simulate on-site white noise. Subsequently, CST simulation models are established for both standard and degraded sensors, quantifying the impact of factors like antenna corrosion on performance parameters such as echo impedance S11 and voltage standing wave ratio (VSWR). Finally, the two sensor models are coupled into GIS handholes for comparative simulation analysis. Results show that antenna corrosion causes resonant frequency shifts in sensors, reducing PD signal power by 55.27% and increasing noise power by 64.11%. The signal-to-noise ratio (SNR) decreases from −9.70 dB to −15.34 dB, with evident waveform distortion in the double-exponential PD pulses. These conclusions provide theoretical references for on-site UHF sensor calibration in noisy environments.