Haitao Yang
Research Subjects
Research Interests
Haitao Yang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Jie Wu
State Grid Anhui Electric Power Research Institute , Hefei 230600
1 shared publication - Lujia Wang
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Xingwang Wu
Electric Power Research Institute, State Grid Anhui Electric Power Co., Ltd., Hefei 230601, China
1 shared publication - Yiming Xie
Electric Power Research Institute, State Grid Anhui Electric Power Co., Ltd., Hefei 230601, China
1 shared publication - Yongze Yang
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication - Zixi Zhu
School of Electrical Engineering, China University of Mining and Technology, Xuzhou 221116, China
1 shared publication
Latest Publications
- Open Access
Simulation Study on Anti-Interference Performance Degradation of GIS UHF Sensors Based on Substation White Noise Reconstruction
The ultra-high frequency (UHF)-based partial discharge (PD) detection technology for gas-insulated switchgear (GIS) has achieved large-scale applications due to its high sensitivity and real-time monitoring capabilities. However, long-term service-induced antenna corrosion in UHF sensors may lead to degraded reception characteristics. To ensure the credibility of monitoring data, on-site sensor calibration under ambient noise conditions is required. This study first analyzes the time–frequency domain characteristics of white noise received by UHF sensors in GIS environments. Leveraging the transceiver reciprocity principle of sensors, a noise reconstruction method based on external sensors is proposed to simulate on-site white noise. Subsequently, CST simulation models are established for both standard and degraded sensors, quantifying the impact of factors like antenna corrosion on performance parameters such as echo impedance S11 and voltage standing wave ratio (VSWR). Finally, the two sensor models are coupled into GIS handholes for comparative simulation analysis. Results show that antenna corrosion causes resonant frequency shifts in sensors, reducing PD signal power by 55.27% and increasing noise power by 64.11%. The signal-to-noise ratio (SNR) decreases from −9.70 dB to −15.34 dB, with evident waveform distortion in the double-exponential PD pulses. These conclusions provide theoretical references for on-site UHF sensor calibration in noisy environments.
Open AccessSimulation Study on Anti-Interference Performance Degradation of GIS UHF Sensors Based on Substation White Noise Reconstruction
The ultra-high frequency (UHF)-based partial discharge (PD) detection technology for gas-insulated switchgear (GIS) has achieved large-scale applications due to its high sensitivity and real-time monitoring capabilities. However, long-term service-induced antenna corrosion in UHF sensors may lead to degraded reception characteristics. To ensure the credibility of monitoring data, on-site sensor calibration under ambient noise conditions is required. This study first analyzes the time–frequency domain characteristics of white noise received by UHF sensors in GIS environments. Leveraging the transceiver reciprocity principle of sensors, a noise reconstruction method based on external sensors is proposed to simulate on-site white noise. Subsequently, CST simulation models are established for both standard and degraded sensors, quantifying the impact of factors like antenna corrosion on performance parameters such as echo impedance S11 and voltage standing wave ratio (VSWR). Finally, the two sensor models are coupled into GIS handholes for comparative simulation analysis. Results show that antenna corrosion causes resonant frequency shifts in sensors, reducing PD signal power by 55.27% and increasing noise power by 64.11%. The signal-to-noise ratio (SNR) decreases from −9.70 dB to −15.34 dB, with evident waveform distortion in the double-exponential PD pulses. These conclusions provide theoretical references for on-site UHF sensor calibration in noisy environments.