Changyue Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Changyue Luo has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Zhenghong Tian
Hohai University
2 shared publications - Cong Zhang
CCCC Fourth Harbor Engineering Co., Ltd., Guangzhou 510200, China
1 shared publication - Fazhang Li
CCCC Fourth Harbor Engineering Co., Ltd., No. 368 Lijiao Road, Haizhu District, Guangzhou 510290, China
1 shared publication - Guanguo Liu
Affiliation JSTI GROUP Co., Ltd., Nanjing, Jiangsu, China
1 shared publication - Huidong Qu
CCCC Fourth Harbor Engineering Co., Ltd., No. 368 Lijiao Road, Haizhu District, Guangzhou 510290, China
1 shared publication - Linen Li
CCCC Fourth Harbor Engineering Co., Ltd., Guangzhou 510200, China
1 shared publication
Latest Publications
- Open Access
- 28 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8563
Field-Informed Hydro-Mechanical Identification and Data-Driven Inversion of an Equivalent Groundwater Leakage Pathway in a Deep Ship-Lock Excavation Along the Xiangjiang River, China
Localized groundwater leakage through retaining and cutoff systems can reorganize hydraulic gradients and trigger deformation that is difficult to distinguish from the normal response to excavation and dewatering. This study tests whether spatial deformation residuals, interpreted with transient hydro-mechanical modeling, can identify and characterize an equivalent leakage pathway at a 31 m-deep ship-lock excavation along the Xiangjiang River, China. A three-dimensional fully coupled model using the Hardening Soil model with small-strain stiffness was validated against inclinometer and surface-settlement measurements. Relative error in maximum wall displacement was 7.1% with transient seepage, compared with 18.7% under a steady-state assumption. At the final excavation stage, residual screening localized anomalous deformation to monitoring sections SC08–SC09 and vertical coordinates Z = −22 to −19 m, within the rounded-gravel layer. A local permeable zone was subsequently introduced into the equivalent wall, and 200 orthogonal Latin hypercube simulations sampled its hydraulic conductivity, equivalent area and position. Within the investigated ranges, hydraulic conductivity and equivalent area caused the largest deformation changes. The CNN–BiGRU surrogate yielded an independent-test coefficient of determination R2 of 0.93 and yielded k = 6.5 × 10−4 cm s−1, A = 16.2 cm2, Z = −20.8 m and X = 32.7 m. To quantify the reported k–A non-uniqueness, a dense sweep of 10,201 k–A combinations was performed at the inverted X and Z coordinates, producing a low-misfit feasible valley in the k–A plane. For a normalized response misfit not exceeding 10%, the feasible combinations were approximately k = 2.8 × 10−4 to 1.6 × 10−3 cm s−1 and A = 10.0 to 22.5 cm2, while the minimum-misfit core (J ≤ 8%) clustered around k = 4.8 × 10−4 to 8.8 × 10−4 cm s−1 and A = 13.5 to 18.8 cm2. Reintroduction of the inverted parameters reproduced wall displacement and ground settlement within 6.9–8.1% of field measurements. The inferred parameters represent an equivalent seepage channel rather than a unique defect geometry, and the feasible-region analysis shows that hydraulic conductance is better constrained than k or A individually.
- 28 August 2026
- Published by MDPI AG in Applied Sciences
- Vol. 16 (17) , 8563
Open AccessField-Informed Hydro-Mechanical Identification and Data-Driven Inversion of an Equivalent Groundwater Leakage Pathway in a Deep Ship-Lock Excavation Along the Xiangjiang River, China
Localized groundwater leakage through retaining and cutoff systems can reorganize hydraulic gradients and trigger deformation that is difficult to distinguish from the normal response to excavation and dewatering. This study tests whether spatial deformation residuals, interpreted with transient hydro-mechanical modeling, can identify and characterize an equivalent leakage pathway at a 31 m-deep ship-lock excavation along the Xiangjiang River, China. A three-dimensional fully coupled model using the Hardening Soil model with small-strain stiffness was validated against inclinometer and surface-settlement measurements. Relative error in maximum wall displacement was 7.1% with transient seepage, compared with 18.7% under a steady-state assumption. At the final excavation stage, residual screening localized anomalous deformation to monitoring sections SC08–SC09 and vertical coordinates Z = −22 to −19 m, within the rounded-gravel layer. A local permeable zone was subsequently introduced into the equivalent wall, and 200 orthogonal Latin hypercube simulations sampled its hydraulic conductivity, equivalent area and position. Within the investigated ranges, hydraulic conductivity and equivalent area caused the largest deformation changes. The CNN–BiGRU surrogate yielded an independent-test coefficient of determination R2 of 0.93 and yielded k = 6.5 × 10−4 cm s−1, A = 16.2 cm2, Z = −20.8 m and X = 32.7 m. To quantify the reported k–A non-uniqueness, a dense sweep of 10,201 k–A combinations was performed at the inverted X and Z coordinates, producing a low-misfit feasible valley in the k–A plane. For a normalized response misfit not exceeding 10%, the feasible combinations were approximately k = 2.8 × 10−4 to 1.6 × 10−3 cm s−1 and A = 10.0 to 22.5 cm2, while the minimum-misfit core (J ≤ 8%) clustered around k = 4.8 × 10−4 to 8.8 × 10−4 cm s−1 and A = 13.5 to 18.8 cm2. Reintroduction of the inverted parameters reproduced wall displacement and ground settlement within 6.9–8.1% of field measurements. The inferred parameters represent an equivalent seepage channel rather than a unique defect geometry, and the feasible-region analysis shows that hydraulic conductance is better constrained than k or A individually.
- Open Access
Research on the Intelligent Vibrating Robot System for Prefabricated Beams Based on Digital Twin Technology
To address the issues of vibration blind spots and the “black box” of quality control in the vibration process of precast beams caused by dense reinforcement zones and the arbitrariness of manual operation, this paper proposes the development of a closed-loop intelligent vibration system. This system integrates intelligent equipment, evaluation models, adaptive algorithms, and digital twin feedback control. By combining drum-type vibration robots for large-scale operations with wearable sensing devices for complex dead corners, full coverage of the operation area is achieved. Second, based on the coupling mechanism of mechanical-electrical-hydraulic multi-physics fields, a quantitative evaluation model for vibration compactness is established. Furthermore, a hierarchical adaptive control strategy based on feedback of the rheological state is designed. By fusing real-time positioning data with vibration energy indices, process parameters such as vibration frequency and duration are dynamically optimized. Finally, through the developed digital twin feedback control platform, a vibration energy cloud map reflecting the internal quality can be generated in real time, thereby achieving process visualization and early warning of defects. Results show that the system can accurately detect and resolve missed and insufficient vibration issues. Construction activities are thus managed via data rather than subjective empirical judgment.
Open AccessResearch on the Intelligent Vibrating Robot System for Prefabricated Beams Based on Digital Twin Technology
To address the issues of vibration blind spots and the “black box” of quality control in the vibration process of precast beams caused by dense reinforcement zones and the arbitrariness of manual operation, this paper proposes the development of a closed-loop intelligent vibration system. This system integrates intelligent equipment, evaluation models, adaptive algorithms, and digital twin feedback control. By combining drum-type vibration robots for large-scale operations with wearable sensing devices for complex dead corners, full coverage of the operation area is achieved. Second, based on the coupling mechanism of mechanical-electrical-hydraulic multi-physics fields, a quantitative evaluation model for vibration compactness is established. Furthermore, a hierarchical adaptive control strategy based on feedback of the rheological state is designed. By fusing real-time positioning data with vibration energy indices, process parameters such as vibration frequency and duration are dynamically optimized. Finally, through the developed digital twin feedback control platform, a vibration energy cloud map reflecting the internal quality can be generated in real time, thereby achieving process visualization and early warning of defects. Results show that the system can accurately detect and resolve missed and insufficient vibration issues. Construction activities are thus managed via data rather than subjective empirical judgment.
- Open Access
Study on Vibration Compaction Behavior of Fresh Concrete Mixture with Ternary Aggregate Grading
The vibration compaction behavior of fully graded fresh concrete differs fundamentally from that of conventional two-graded concrete. Based on measured vibration responses of an internal vibrator and sinking-ball tests, an energy transfer model for fully graded concrete was established by incorporating the effects of aggregate-specific surface area, paste–aggregate ratio, dynamic damping, and natural frequency, and the spatiotemporal attenuation of vibration energy in fresh concrete was systematically analyzed. Experimental results indicate that fully graded concrete exhibits a higher energy absorption capacity during the early stage of vibration, with a maximum energy absorption rate of 423 W and a peak energy transfer efficiency of 76.3%, both of which are significantly higher than those of two-graded concrete at the same slump. However, as a dense aggregate skeleton rapidly forms, the energy absorption efficiency of fully graded concrete decreases more rapidly during the middle and later stages of vibration, showing a characteristic pattern of “high initial absorption followed by rapid attenuation.” Through segregation assessment and porosity analysis, a safe vibration energy range for fully graded concrete was quantitatively determined, with lower and upper energy thresholds of 159.7 J·kg−1 and 538.5 J·kg−1, respectively. In addition, the experiments identified recommended vibration durations of 30–65 s and effective vibration influence radii of 22–85 mm for fully graded concrete under different slump conditions. These findings provide a quantitative basis for the control of vibration parameters and energy-oriented construction of fully graded concrete.
Open AccessStudy on Vibration Compaction Behavior of Fresh Concrete Mixture with Ternary Aggregate Grading
The vibration compaction behavior of fully graded fresh concrete differs fundamentally from that of conventional two-graded concrete. Based on measured vibration responses of an internal vibrator and sinking-ball tests, an energy transfer model for fully graded concrete was established by incorporating the effects of aggregate-specific surface area, paste–aggregate ratio, dynamic damping, and natural frequency, and the spatiotemporal attenuation of vibration energy in fresh concrete was systematically analyzed. Experimental results indicate that fully graded concrete exhibits a higher energy absorption capacity during the early stage of vibration, with a maximum energy absorption rate of 423 W and a peak energy transfer efficiency of 76.3%, both of which are significantly higher than those of two-graded concrete at the same slump. However, as a dense aggregate skeleton rapidly forms, the energy absorption efficiency of fully graded concrete decreases more rapidly during the middle and later stages of vibration, showing a characteristic pattern of “high initial absorption followed by rapid attenuation.” Through segregation assessment and porosity analysis, a safe vibration energy range for fully graded concrete was quantitatively determined, with lower and upper energy thresholds of 159.7 J·kg−1 and 538.5 J·kg−1, respectively. In addition, the experiments identified recommended vibration durations of 30–65 s and effective vibration influence radii of 22–85 mm for fully graded concrete under different slump conditions. These findings provide a quantitative basis for the control of vibration parameters and energy-oriented construction of fully graded concrete.