WSWeihao Shuai

Weihao Shuai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Weihao Shuai has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Fang Chen

    State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China

    1 shared publication
  • Han Yang

    State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China

    1 shared publication
  • Hao Bai

    Electric Power Research Institute, China Southern Power Grid, Guangzhou 510620, China

    1 shared publication
  • Junjie Sun

    College of Electrical and Information Engineering, Hunan University, Changsha 410082, China

    1 shared publication
  • Meng Liu

    State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China

    1 shared publication
  • Ming Yang

    State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China

    1 shared publication

Latest Publications

  • Open Access

    A DMPC-Based Secondary Harmonic Compensation Strategy via Adaptive Virtual Admittance Tuning

    by Fang Chen, Zhengyu Wang, Meng Liu, Junjie Sun, Han Yang, Ming Yang, Yanyi Fu, Weihao Shuai, Yelun Peng

    A large number of grid-connected inverters have been connected to distribution networks and can be used to mitigate harmonics at the system level. Deploying distributed power electronic devices for harmonic mitigation is a cost-effective solution for distribution networks. However, existing coordination methods typically depend on highly reliable, low-latency communications. Communication delays or interruptions can significantly degrade coordination performance and even exacerbate harmonic distortion. This paper presents a hierarchical, coordinated harmonic compensation method for multiple multifunctional grid-tied inverters (MFGTIs). At the primary control level, harmonic domain virtual admittance is incorporated, enabling each device to adaptively inject harmonic compensation currents using only local measurements, maintaining baseline compensation capability when communication is limited or interrupted. At the secondary control level, a distributed model predictive control (DMPC) scheme is derived from the harmonic steady-state equivalent circuit. The virtual admittance parameters are updated iteratively using measurements exchanged only among neighboring nodes, enabling coordinated sharing of compensation currents without requiring global information or frequent harmonic power flow calculations. Case studies demonstrate that the proposed method reduces nodal harmonic voltages under communication constrained conditions while significantly lowering the computational burden.

  • Open Access

    Transient Voltage Support Strategy for Microgrids at the Distribution Network Edge Considering Cable Capacitance

    by Shiran Cao, Ruotian Yao, Weihao Shuai, Hao Bai, Shiqi Jiang, Yawen Zheng

    Microgrids are commonly connected through medium-voltage cables in coastal distribution networks and other microgrids. However, a faulted microgrid may increase the collapse risk if the supporting microgrids are disconnected due to voltage sags. Conventional voltage support methods, which primarily rely on the impedance characteristics of the transmission line, typically regulate the active-to-reactive current ratio (hereafter referred to as “current ratio”) to maximize positive sequence voltage while minimizing negative sequence voltage. Nevertheless, the distributed capacitance inherent in cables induces deviations in both the amplitude and phase of the transmitted current, while simultaneously intensifying the coupling between voltage and current. These effects complicate the voltage fluctuation behavior and impair the effectiveness of voltage support, thereby increasing the risk of disconnection and collapse for the faulted microgrid (hereafter referred to as “fault region”). To address this challenge, this study focuses on non-faulted microgrids (hereafter referred to as “microgrids”), proposing a method for active current correction and transient voltage support that considers the influence of cable distributed capacitance. By analyzing the voltage and current characteristics on both ends of the interconnecting cables, the method optimizes the current injection ratio. It mitigates deviation caused by cable capacitance effects, thereby enhancing the voltage support performance of the microgrid. Notably, the proposed method operates independently of real-time voltage and current measurements from the fault region, significantly reducing communication demands. Experimental results based on a practical microgrid validate the effectiveness of the proposed method, demonstrating a 27.9% improvement in voltage support performance compared to conventional methods.