Junjie Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Junjie Sun has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Fang Chen
State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China
1 shared publication - Han Yang
State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China
1 shared publication - Meng Liu
State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China
1 shared publication - Ming Yang
State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China
1 shared publication - Weihao Shuai
College of Electrical and Information Engineering, Hunan University, Changsha 410082, China
1 shared publication - Yanyi Fu
State Grid Hunan Electric Power Company Limited Technical Training Center (Changsha Electric Power Technical College), Changsha 410131, China
1 shared publication
Latest Publications
- Open Access
A DMPC-Based Secondary Harmonic Compensation Strategy via Adaptive Virtual Admittance Tuning
A large number of grid-connected inverters have been connected to distribution networks and can be used to mitigate harmonics at the system level. Deploying distributed power electronic devices for harmonic mitigation is a cost-effective solution for distribution networks. However, existing coordination methods typically depend on highly reliable, low-latency communications. Communication delays or interruptions can significantly degrade coordination performance and even exacerbate harmonic distortion. This paper presents a hierarchical, coordinated harmonic compensation method for multiple multifunctional grid-tied inverters (MFGTIs). At the primary control level, harmonic domain virtual admittance is incorporated, enabling each device to adaptively inject harmonic compensation currents using only local measurements, maintaining baseline compensation capability when communication is limited or interrupted. At the secondary control level, a distributed model predictive control (DMPC) scheme is derived from the harmonic steady-state equivalent circuit. The virtual admittance parameters are updated iteratively using measurements exchanged only among neighboring nodes, enabling coordinated sharing of compensation currents without requiring global information or frequent harmonic power flow calculations. Case studies demonstrate that the proposed method reduces nodal harmonic voltages under communication constrained conditions while significantly lowering the computational burden.
Open AccessA DMPC-Based Secondary Harmonic Compensation Strategy via Adaptive Virtual Admittance Tuning
A large number of grid-connected inverters have been connected to distribution networks and can be used to mitigate harmonics at the system level. Deploying distributed power electronic devices for harmonic mitigation is a cost-effective solution for distribution networks. However, existing coordination methods typically depend on highly reliable, low-latency communications. Communication delays or interruptions can significantly degrade coordination performance and even exacerbate harmonic distortion. This paper presents a hierarchical, coordinated harmonic compensation method for multiple multifunctional grid-tied inverters (MFGTIs). At the primary control level, harmonic domain virtual admittance is incorporated, enabling each device to adaptively inject harmonic compensation currents using only local measurements, maintaining baseline compensation capability when communication is limited or interrupted. At the secondary control level, a distributed model predictive control (DMPC) scheme is derived from the harmonic steady-state equivalent circuit. The virtual admittance parameters are updated iteratively using measurements exchanged only among neighboring nodes, enabling coordinated sharing of compensation currents without requiring global information or frequent harmonic power flow calculations. Case studies demonstrate that the proposed method reduces nodal harmonic voltages under communication constrained conditions while significantly lowering the computational burden.