Ergin Taşkin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ergin Taşkin has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Ali Erdem Öztürk
Department of Reproduction and Artificial Insemination, Faculty of Veterinary Medicine, Erciyes University, Kayseri, Türkiye
1 shared publication - Ayse Sebnem Erenler
Department of Medical Biology, Faculty of Medicine, Malatya Turgut Ozal University, Malatya, Turkey
1 shared publication - Deniz Bakır
Sivas Cumhuriyet University, University Hospital, Biochemistry Labratory
1 shared publication Dilek Taşkin
Department of Medical Biochemistry Laboratory, Ağrı Training and Research Hospital, Ağrı, Turkey
1 shared publicationEbubekir Bakan
Department of Medical Biochemistry, Faculty of Medicine, Kafkas University, Kars, Turkey
1 shared publicationElif Büşra Topal
1 shared publication
Latest Publications
- Open Access
- 4 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Comparative analysis of hemoglobin a1c measurement methods: inter-device agreement and clinical impact
Glycated hemoglobin (HbA1c) is widely recommended for the diagnosis and monitoring of diabetes mellitus (DM). Minimal changes in HbA1c concentration can influence clinical decisions, making accurate and interference-free measurement essential. To compare the analytical performance and inter-method agreement of three HbA1c measurement techniques-Capillary Electrophoresis, High-Performance Liquid Chromatography (HPLC), and Turbidimetric Immunoinhibition-used in routine clinical practice. Fifty EDTA-anticoagulated patient samples were consecutively analyzed using HPLC (Tosoh G8), Capillary Electrophoresis (Sebia Capillarys 3 Tera), and an autoanalyzer (Beckman DXC 700 AU). Results were stratified into four HbA1c ranges (4-6%, 6-8%, 8-10%, 10-12%) and analyzed using Pearson correlation, Bland-Altman, and Passing-Bablok regression. Capillary Electrophoresis and HPLC showed a high degree of agreement (r = 0.998, bias = 0.07). Capillary Electrophoresis vs. autoanalyzer also demonstrated high correlation (r = 0.997) but a larger bias (0.52) that increased at higher concentrations. HPLC vs. autoanalyzer yielded r = 0.997 and bias = 0.45, with proportional bias at high HbA1c levels. Passing-Bablok analysis confirmed concentration-dependent deviations for the autoanalyzer. Capillary Electrophoresis and HPLC provide highly consistent HbA1c results, while the autoanalyzer may introduce clinically relevant bias, particularly at higher HbA1c levels, which may influence clinical interpretation near commonly used decision thresholds. However, given the limited sample size, these findings should be interpreted with caution.
- 4 June 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessComparative analysis of hemoglobin a1c measurement methods: inter-device agreement and clinical impact
Glycated hemoglobin (HbA1c) is widely recommended for the diagnosis and monitoring of diabetes mellitus (DM). Minimal changes in HbA1c concentration can influence clinical decisions, making accurate and interference-free measurement essential. To compare the analytical performance and inter-method agreement of three HbA1c measurement techniques-Capillary Electrophoresis, High-Performance Liquid Chromatography (HPLC), and Turbidimetric Immunoinhibition-used in routine clinical practice. Fifty EDTA-anticoagulated patient samples were consecutively analyzed using HPLC (Tosoh G8), Capillary Electrophoresis (Sebia Capillarys 3 Tera), and an autoanalyzer (Beckman DXC 700 AU). Results were stratified into four HbA1c ranges (4-6%, 6-8%, 8-10%, 10-12%) and analyzed using Pearson correlation, Bland-Altman, and Passing-Bablok regression. Capillary Electrophoresis and HPLC showed a high degree of agreement (r = 0.998, bias = 0.07). Capillary Electrophoresis vs. autoanalyzer also demonstrated high correlation (r = 0.997) but a larger bias (0.52) that increased at higher concentrations. HPLC vs. autoanalyzer yielded r = 0.997 and bias = 0.45, with proportional bias at high HbA1c levels. Passing-Bablok analysis confirmed concentration-dependent deviations for the autoanalyzer. Capillary Electrophoresis and HPLC provide highly consistent HbA1c results, while the autoanalyzer may introduce clinically relevant bias, particularly at higher HbA1c levels, which may influence clinical interpretation near commonly used decision thresholds. However, given the limited sample size, these findings should be interpreted with caution.
- Open Access
- 25 June 2023
- Published by Özgür Yayınları
- p. 1-56
An Overview of Intracytoplasmic Sperm Injection (ICSI): Its Development and Popularity
Assisted reproductive technology (ART) is widely used in infertility treatments to achieve pregnancy. This technology includes in vitro fertilization (IVF) and microinjection (Intracytoplasmic Sperm Injection-ICSI) procedures. Today, ICSI is the most commonly used fertilization method for both severe male factor infertility and non-male-induced infertility in many laboratories all over the world. In this method, a sperm cell is injected into the cytoplasm of an oocyte cell under a microscope with a micromanipulator attached. Although it is a popular method of insemination, it has various indications. In ART treatments, gametes and zygotes are exposed to a non-physiological treatment and culture medium. It is known that this process and environment that they are exposed to can affect the epigenetic properties of male and female gametes and may negatively affect the early embryogenesis process. While most children born with the ICSI method appear healthy, there are concerns about the safety and overuse of this technology. When the health status of children born with ICSI is analyzed to date, it has been suggested that children born with ICSI have more congenital malformations, epigenetic disorders, chromosomal anomalies, psychological and neurological developmental disorders than children born naturally. However, it is still unclear how much of the observed adverse outcomes are related to parental factors or ICSI. In this review, we aimed to discuss the ICSI method, its development and data on epigenetic risks in the light of literature information.
- 25 June 2023
- Published by Özgür Yayınları
- p. 1-56
Open AccessAn Overview of Intracytoplasmic Sperm Injection (ICSI): Its Development and Popularity
Assisted reproductive technology (ART) is widely used in infertility treatments to achieve pregnancy. This technology includes in vitro fertilization (IVF) and microinjection (Intracytoplasmic Sperm Injection-ICSI) procedures. Today, ICSI is the most commonly used fertilization method for both severe male factor infertility and non-male-induced infertility in many laboratories all over the world. In this method, a sperm cell is injected into the cytoplasm of an oocyte cell under a microscope with a micromanipulator attached. Although it is a popular method of insemination, it has various indications. In ART treatments, gametes and zygotes are exposed to a non-physiological treatment and culture medium. It is known that this process and environment that they are exposed to can affect the epigenetic properties of male and female gametes and may negatively affect the early embryogenesis process. While most children born with the ICSI method appear healthy, there are concerns about the safety and overuse of this technology. When the health status of children born with ICSI is analyzed to date, it has been suggested that children born with ICSI have more congenital malformations, epigenetic disorders, chromosomal anomalies, psychological and neurological developmental disorders than children born naturally. However, it is still unclear how much of the observed adverse outcomes are related to parental factors or ICSI. In this review, we aimed to discuss the ICSI method, its development and data on epigenetic risks in the light of literature information.