L Navarro-Cozcolluela
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
L Navarro-Cozcolluela has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
E Oblak
Donostia International Physics Center, Manuel Lardizabal Ibilbidea, 4, San Sebastián, Gipuzkoa, 20018, SPAIN
1 shared publicationF Lopez
Donostia International Physics Center, Manuel Lardizabal Ibilbidea, 4, San Sebastián, PV, 20018, SPAIN
1 shared publication- Francesco Monrabal
Donostia International Physics Center
1 shared publication J García-Barrena
Instituto de Instrumentacion para Imagen Molecular, Av. dels Tarongers, 12, Valencia, Valencian Community, 46022, SPAIN
1 shared publicationJ Toledo
Instituto de Instrumentacion para Imagen Molecular, Camino de Vera 46022,Valencia Valencia, Valencian Community, 46022, SPAIN
1 shared publication- J. Renner
Universidade de Santiago de Compostela
1 shared publication
Latest Publications
- Open Access
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025001
CRYSP: a total-body PET based on cryogenic cesium iodide crystals
Objective. Total body positron emission tomography (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. Approach. We investigate the performance of pure CsI crystals operated at cryogenic temperatures (∼100 K), where they achieve a light yield of approximately 10 5 photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction (d.o.i.) capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Main results. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution (CTR) at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. Significance. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings.
- 20 January 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (2) , 025001
Open AccessCRYSP: a total-body PET based on cryogenic cesium iodide crystals
Objective. Total body positron emission tomography (TBPET) scanners have the potential to substantially reduce both acquisition time and administered radiation dose, owing to their high sensitivity. However, their widespread clinical adoption is hindered by the high cost of currently available systems. This work explores the use of pure cesium iodide (CsI) monolithic crystals operated at cryogenic temperatures as a cost-effective alternative to rare-earth scintillators for TBPET. Approach. We investigate the performance of pure CsI crystals operated at cryogenic temperatures (∼100 K), where they achieve a light yield of approximately 10 5 photons/MeV. The implications for energy resolution, spatial resolution (including depth-of-interaction (d.o.i.) capability), and timing performance are assessed, with a view toward their integration into a TBPET system. Main results. Cryogenic CsI crystals demonstrated energy resolution below 7% and coincidence time resolution (CTR) at the nanosecond level, despite their relatively slow scintillation decay time. A Monte Carlo simulation of monolithic CsI crystals shows that a millimeter-scale spatial resolution in all three dimensions can be obtained. These characteristics indicate that high-performance PET imaging is achievable with this technology. Significance. A TBPET scanner based on cryogenic CsI monolithic crystals could combine excellent imaging performance with significantly reduced detector costs, enabling broader accessibility and accelerating the adoption of TBPET in both clinical and research settings.