Anisha Karki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anisha Karki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Dong Won Jung
2 shared publications- Ai Ting
Department of Mechanical Engineering, Jeju National University, Jeju 63243, Republic of Korea
1 shared publication - Atif Niaz
Jeju National University
1 shared publication - Dong Won Jung
Faculty of Applied Energy System, Major of Mechanical Engineering, Jeju National University, Jeju-Si, Republic of Korea
1 shared publication - Ji-Hyun Jeong
Department of Mechanical Engineering, Jeju National University, Jeju 63243, Republic of Korea
1 shared publication - Osama Ali
Jeju National University
1 shared publication
Latest Publications
- Open Access
- 12 February 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Smart design of overhead cranes using artificial intelligence and multi-objective optimization via evolutionary algorithms
- 12 February 2026
- Published by Elsevier in Results in Engineering
- Vol. 29
Open AccessSmart design of overhead cranes using artificial intelligence and multi-objective optimization via evolutionary algorithms
- Open Access
Thermo-Structural and Dynamic Performance Analysis of a 42CrMo4 Steel Ball Screw Assembly
This study presents a comprehensive thermo-structural and modal analysis of a ball screw assembly. Thermal analysis revealed a maximum temperature of 29.1 °C at the ball nut, corresponding to a total rise of 7.1 °C above ambient. The resulting thermal deformation reached 77.81 μm, while the von Mises stress peaked at 53.9 MPa, both within acceptable limits. Modal simulation of 360 modes showed a sharp increase in frequency with mode number and larger deformation patterns at the higher modes. The first two modes dominate the effective mass with the first 8 modes capturing over 90% of the cumulative effective mass. Overall, the results demonstrate stable thermal performance, limited deformation, low stress, and controlled vibrations, confirming the modeling approach and the suitability of 42CrMo4 steel for high-precision ball screw assemblies.
Open AccessThermo-Structural and Dynamic Performance Analysis of a 42CrMo4 Steel Ball Screw Assembly
This study presents a comprehensive thermo-structural and modal analysis of a ball screw assembly. Thermal analysis revealed a maximum temperature of 29.1 °C at the ball nut, corresponding to a total rise of 7.1 °C above ambient. The resulting thermal deformation reached 77.81 μm, while the von Mises stress peaked at 53.9 MPa, both within acceptable limits. Modal simulation of 360 modes showed a sharp increase in frequency with mode number and larger deformation patterns at the higher modes. The first two modes dominate the effective mass with the first 8 modes capturing over 90% of the cumulative effective mass. Overall, the results demonstrate stable thermal performance, limited deformation, low stress, and controlled vibrations, confirming the modeling approach and the suitability of 42CrMo4 steel for high-precision ball screw assemblies.
- Open Access
- 11 August 2025
- Published by Academic Science Publications and Distributions in International Journal of Environmental Sciences
- p. 817-825
Seismic Qualification Of An Exhaust Gas Silencer In A Nuclear Power Plant Using Finite Element Analysis
This study presents the seismic qualification of an Exhaust Gas Silencer (EGS) installed in the Emergency Diesel Generator (EDG) system of a nuclear power plant. Using Finite Element Analysis (FEA) with ANSYS 12.1, the structural performance of the EGS was assessed under normal, upset (½ Safe Shutdown Earthquake), and faulted (Safe Shutdown Earthquake) conditions, in accordance with KEPIC MN Class 3 and ASME Section III standards. Modal analysis confirmed a fundamental natural frequency of 69.13 Hz, exceeding the 33 Hz threshold, thereby validating the use of equivalent static seismic analysis. Locations of analysis which were critical, including saddle supports, head-to-shell junctions and reinforced areas, proved that the maximum combined membrane and bending stresses did not exceed those defined by code. The maximum stress of 240.62 MPa was observed at the reinforced angle, which remained below the permissible stress of 243.12 MPa during faulted seismic loading. These findings justify the structural integrity and seismic resilience of the EGS.By maintaining emission control during seismic events, the qualified EGS ensures safe dispersal of exhaust gases, preventing uncontrolled environmental release and supporting sustainability in nuclear operations.The study also establishes a replicable and code-compliant methodology for qualifying auxiliary components in nuclear systems subjected to seismic loading.
- 11 August 2025
- Published by Academic Science Publications and Distributions in International Journal of Environmental Sciences
- p. 817-825
Open AccessSeismic Qualification Of An Exhaust Gas Silencer In A Nuclear Power Plant Using Finite Element Analysis
This study presents the seismic qualification of an Exhaust Gas Silencer (EGS) installed in the Emergency Diesel Generator (EDG) system of a nuclear power plant. Using Finite Element Analysis (FEA) with ANSYS 12.1, the structural performance of the EGS was assessed under normal, upset (½ Safe Shutdown Earthquake), and faulted (Safe Shutdown Earthquake) conditions, in accordance with KEPIC MN Class 3 and ASME Section III standards. Modal analysis confirmed a fundamental natural frequency of 69.13 Hz, exceeding the 33 Hz threshold, thereby validating the use of equivalent static seismic analysis. Locations of analysis which were critical, including saddle supports, head-to-shell junctions and reinforced areas, proved that the maximum combined membrane and bending stresses did not exceed those defined by code. The maximum stress of 240.62 MPa was observed at the reinforced angle, which remained below the permissible stress of 243.12 MPa during faulted seismic loading. These findings justify the structural integrity and seismic resilience of the EGS.By maintaining emission control during seismic events, the qualified EGS ensures safe dispersal of exhaust gases, preventing uncontrolled environmental release and supporting sustainability in nuclear operations.The study also establishes a replicable and code-compliant methodology for qualifying auxiliary components in nuclear systems subjected to seismic loading.