Eugeniusz Pilat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eugeniusz Pilat has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Weglarzy
Department of Cardiac Anaesthesia and Intensive Care Upper‐Silesian Medical Centre in Katowice Katowice Poland
1 shared publication - Anna Drzewiecka
Department of Electrocardiology, Upper-Silesian Medical Centre in Katowice, Ziolowa 45/47 Str., 40-635 Katowice, Poland
1 shared publication - Joanna Stachanczyk
Department of Cardiac Rehabilitation Murcki Hospital Katowice Poland
1 shared publication - Jolanta Biernat
Department of Electrocardiology and Heart Failure, Upper-Silesian Medical Center, Ziolowa 45/47 Str., 40-635 Katowice, Poland
1 shared publication - Krzysztof Stanislaw Golba
Department of Electrocardiology and Heart Failure, Medical University of Silesia, 40-635 Katowice, Poland
1 shared publication - Michal Joniec
Department of Electrocardiology, Upper-Silesian Medical Centre in Katowice, 40-635 Katowice, Poland
1 shared publication
Latest Publications
- Open Access
- 9 January 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (3) , 493-500
Symptomatic Deep Venous Thrombosis of the Upper Extremity Following Transvenous Lead Extraction, Data From EXTRACT Registry
Background: Venous thrombosis occurring after TLE procedures is a fairly common but poorly described complication and requires further investigation into its causes. Aim: The aim of this study was to identify independent predictors of UEDVT occurrence after TLE procedures. Methods: We analyzed data from 504 transvenous lead extraction procedures performed in the hybrid surgery room of the Department of Electrocardiology and Heart Failure at the Medical University of Silesia, Katowice, Poland, between January 2016 and May 2022. All procedures were performed using mechanical‐only techniques. Results: In the analyzed period, as a result of 504 transvenous extraction procedures of cardiac implantable electronic device leads, 19 (3.8%) cases of symptomatic venous thrombosis of the upper extremity on the side of the procedure occurred. The mean age of patients who developed the complication was 65.8 ± 13.3 years, and 68.4% were men, which did not differ significantly from the general group. Based on variables selected in the univariate analysis, a logistic regression model of risk factors for UEDVT was calculated. These include a history of cancer disease in patients ( p = 0.0110), heart failure according to the Class IV NYHA scale ( p = 0.0397), advanced longest dwell time ( p = 0.0323), extraction of atrial lead ( p = 0.0368), and the use of mechanical non‐powered telescopic sheaths ( p = 0.0455). As protective factors were assessed, infectious indications for TLE ( p = 0.0288) and the highest platelet concentration ( p = 0.0448). Conclusions: Thrombosis is a relatively rare but serious complication. The precise selection of patients at risk of thrombosis after TLE may increase clinical success. It has been shown that an increased risk of thrombosis after TLE occurs in patients with a history of cancer, with heart failure in NYHA Class IV, and platelet concentration is low, in whom TLE is performed for noninfectious reasons, with the use of additional equipment like mechanical non‐powered telescopic sheaths.
- 9 January 2026
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 37 (3) , 493-500
Open AccessSymptomatic Deep Venous Thrombosis of the Upper Extremity Following Transvenous Lead Extraction, Data From EXTRACT Registry
Background: Venous thrombosis occurring after TLE procedures is a fairly common but poorly described complication and requires further investigation into its causes. Aim: The aim of this study was to identify independent predictors of UEDVT occurrence after TLE procedures. Methods: We analyzed data from 504 transvenous lead extraction procedures performed in the hybrid surgery room of the Department of Electrocardiology and Heart Failure at the Medical University of Silesia, Katowice, Poland, between January 2016 and May 2022. All procedures were performed using mechanical‐only techniques. Results: In the analyzed period, as a result of 504 transvenous extraction procedures of cardiac implantable electronic device leads, 19 (3.8%) cases of symptomatic venous thrombosis of the upper extremity on the side of the procedure occurred. The mean age of patients who developed the complication was 65.8 ± 13.3 years, and 68.4% were men, which did not differ significantly from the general group. Based on variables selected in the univariate analysis, a logistic regression model of risk factors for UEDVT was calculated. These include a history of cancer disease in patients ( p = 0.0110), heart failure according to the Class IV NYHA scale ( p = 0.0397), advanced longest dwell time ( p = 0.0323), extraction of atrial lead ( p = 0.0368), and the use of mechanical non‐powered telescopic sheaths ( p = 0.0455). As protective factors were assessed, infectious indications for TLE ( p = 0.0288) and the highest platelet concentration ( p = 0.0448). Conclusions: Thrombosis is a relatively rare but serious complication. The precise selection of patients at risk of thrombosis after TLE may increase clinical success. It has been shown that an increased risk of thrombosis after TLE occurs in patients with a history of cancer, with heart failure in NYHA Class IV, and platelet concentration is low, in whom TLE is performed for noninfectious reasons, with the use of additional equipment like mechanical non‐powered telescopic sheaths.