Husam Rajab
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Husam Rajab has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Khalil Hajlaoui
College of Engineering, Imam Mohammad Ibn Saud Islamic University (IMSIU), Riyadh, Saudi Arabia
4 shared publications - Rifaqat Ali
Department of Mathematics, Applied College in Mohayil, Asir, King Khalid University, Abha, Saudi Arabia
3 shared publications Ali Fawzi Al-Hussainy
College of Pharmacy, Ahl Al Bayt University, Kerbala, Iraq
2 shared publications- Hana Ihsan Hassan
Department of Radiology Techniques, Health and Medical Techniques College, Alnoor University, Nineveh, Iraq
2 shared publications - Hiba Mushtaq
College of Pharmacy, Gilgamesh Ahliya University, Baghdad, Iraq
2 shared publications Mahmood Jasem Jawad
Department of pharmacy, Al-Zahrawi University College, Karbala, Iraq
2 shared publications
Latest Publications
- 11 September 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
Reduced-order surrogate modeling of non-Newtonian blood stream inside cerebral aneurysm via hybrid POD-transformer networks
Accurate and efficient prediction of hemodynamic parameters is essential for assessing the rupture risk of cerebral aneurysms, particularly in the middle cerebral artery (MCA). In this study, we propose a reduced-order modeling framework that combines proper orthogonal decomposition (POD) with a transformer-based deep learning model to reconstruct and forecast key hemodynamic indicators — velocity components, wall shear stress (WSS), oscillatory shear index (OSI) and pressure (P) — across the pulsatile cardiac cycle. Patient-specific flow simulations were performed under age-dependent inlet conditions for two cohorts (ages 20–39 and 50–59 years) to evaluate the model’s performance under physiologically realistic scenarios. POD was used to extract dominant flow features and reduce the dimensionality of the data, with energy analysis showing that fewer than 10 modes captured over 95% of the energy for velocity and pressure, while OSI required more modes due to its complex oscillatory behavior. The transformer model, trained on the temporal evolution of the POD coefficients, accurately reproduced the flow field dynamics, achieving low reconstruction errors on both training and unseen test data. Comparative analysis revealed that the older age group exhibited more stable OSI behavior, resulting in improved predictive accuracy. In contrast, the younger group, characterized by more dynamic and energetic flow, required more modes and exhibited higher prediction error — particularly in OSI. Overall, the proposed POD [Formula: see text] Transformer framework enables fast and reliable prediction of critical hemodynamic factors with a significant reduction in computational cost. This approach holds promise for large-scale aneurysm studies and real-time clinical applications in personalized risk assessment and treatment planning.
- 11 September 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
Reduced-order surrogate modeling of non-Newtonian blood stream inside cerebral aneurysm via hybrid POD-transformer networks
Accurate and efficient prediction of hemodynamic parameters is essential for assessing the rupture risk of cerebral aneurysms, particularly in the middle cerebral artery (MCA). In this study, we propose a reduced-order modeling framework that combines proper orthogonal decomposition (POD) with a transformer-based deep learning model to reconstruct and forecast key hemodynamic indicators — velocity components, wall shear stress (WSS), oscillatory shear index (OSI) and pressure (P) — across the pulsatile cardiac cycle. Patient-specific flow simulations were performed under age-dependent inlet conditions for two cohorts (ages 20–39 and 50–59 years) to evaluate the model’s performance under physiologically realistic scenarios. POD was used to extract dominant flow features and reduce the dimensionality of the data, with energy analysis showing that fewer than 10 modes captured over 95% of the energy for velocity and pressure, while OSI required more modes due to its complex oscillatory behavior. The transformer model, trained on the temporal evolution of the POD coefficients, accurately reproduced the flow field dynamics, achieving low reconstruction errors on both training and unseen test data. Comparative analysis revealed that the older age group exhibited more stable OSI behavior, resulting in improved predictive accuracy. In contrast, the younger group, characterized by more dynamic and energetic flow, required more modes and exhibited higher prediction error — particularly in OSI. Overall, the proposed POD [Formula: see text] Transformer framework enables fast and reliable prediction of critical hemodynamic factors with a significant reduction in computational cost. This approach holds promise for large-scale aneurysm studies and real-time clinical applications in personalized risk assessment and treatment planning.
- 26 August 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
Computational analysis of hemodynamic alterations induced by calcium channel blockers in MCA cerebral aneurysms
Cerebral vasospasm following subarachnoid hemorrhage (SAH) can severely compromise cerebral perfusion and elevate the risk of ischemic injury. Calcium channel-blocking (CCB) drugs, such as nimodipine, are widely used to alleviate vasospasm by inducing smooth muscle relaxation and vessel dilation. However, the detailed hemodynamic consequences of such pharmacologically induced vasodilation remain poorly understood. In this study, computational fluid dynamics (CFD) simulations were performed on three patient-specific middle cerebral artery (MCA) aneurysm models to investigate the hemodynamic effects of vessel widening representative of the CCB response. Blood was modeled as a Casson non-Newtonian fluid with hematocrit 0.42 and density 1060[Formula: see text]kg/m 3 . Transient, pulsatile flow corresponding to one cardiac cycle (0.89[Formula: see text]s) was simulated, and parameters such as velocity, pressure, wall shear stress (WSS), vorticity, oscillatory shear index (OSI) and area-weighted WSS (AWSS) were analyzed for both the original and widened vessel geometries. The widened (CCB-effect) models exhibited lower peak velocity and pressure, along with a 20–30% reduction in WSS and vorticity intensity at the aneurysm neck. The AWSS decreased by 10–26%, while OSI values declined across all cases, indicating reduced shear oscillations and more stable intra-aneurysmal flow. Flow streamlines and iso-surface visualizations revealed attenuated jet impingement and simplified vortex structures following vessel dilation. The findings demonstrate that CCB-induced vasodilation promotes a favorable hemodynamic environment, characterized by reduced shear load, lower pressure gradients and improved flow stability within cerebral aneurysms. These results provide mechanistic evidence that supports the clinical role of calcium channel blockers not only in preventing vasospasm but also in mitigating hemodynamic stresses that contribute to aneurysm growth and rupture risk.
- 26 August 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
Computational analysis of hemodynamic alterations induced by calcium channel blockers in MCA cerebral aneurysms
Cerebral vasospasm following subarachnoid hemorrhage (SAH) can severely compromise cerebral perfusion and elevate the risk of ischemic injury. Calcium channel-blocking (CCB) drugs, such as nimodipine, are widely used to alleviate vasospasm by inducing smooth muscle relaxation and vessel dilation. However, the detailed hemodynamic consequences of such pharmacologically induced vasodilation remain poorly understood. In this study, computational fluid dynamics (CFD) simulations were performed on three patient-specific middle cerebral artery (MCA) aneurysm models to investigate the hemodynamic effects of vessel widening representative of the CCB response. Blood was modeled as a Casson non-Newtonian fluid with hematocrit 0.42 and density 1060[Formula: see text]kg/m 3 . Transient, pulsatile flow corresponding to one cardiac cycle (0.89[Formula: see text]s) was simulated, and parameters such as velocity, pressure, wall shear stress (WSS), vorticity, oscillatory shear index (OSI) and area-weighted WSS (AWSS) were analyzed for both the original and widened vessel geometries. The widened (CCB-effect) models exhibited lower peak velocity and pressure, along with a 20–30% reduction in WSS and vorticity intensity at the aneurysm neck. The AWSS decreased by 10–26%, while OSI values declined across all cases, indicating reduced shear oscillations and more stable intra-aneurysmal flow. Flow streamlines and iso-surface visualizations revealed attenuated jet impingement and simplified vortex structures following vessel dilation. The findings demonstrate that CCB-induced vasodilation promotes a favorable hemodynamic environment, characterized by reduced shear load, lower pressure gradients and improved flow stability within cerebral aneurysms. These results provide mechanistic evidence that supports the clinical role of calcium channel blockers not only in preventing vasospasm but also in mitigating hemodynamic stresses that contribute to aneurysm growth and rupture risk.
- 12 June 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Nonlinear Resonance Dynamics of SWBNNTs in Viscoelastic Media: Primary, Subharmonic, and Superharmonic Regimes
This study investigates the nonlinear vibrational behavior of single-walled boron nitride nanotubes (SWBNNTs) using a nonlinear Euler–Bernoulli beam model. The governing partial differential equations are reduced to a set of ordinary differential equations through Galerkin’s method employing trigonometric shape functions. The multiple time scales method is then applied to analyze the nonlinear frequency response under primary, subharmonic, and superharmonic resonances, and implicit analytical expressions for the frequency response are derived. A comprehensive parametric study is conducted to examine the influences of stiffness, excitation amplitude, damping coefficient, and detuning parameter on the nonlinear dynamic behavior. The results reveal that increased stiffness significantly suppresses nonlinear effects by enhancing resistance to deformation, while higher excitation amplitudes amplify nonlinear response intensity across all resonance cases. Subharmonic resonance exhibits response trends distinct from those of primary and superharmonic resonances, although their overall effectiveness remains comparable. Backbone curve curvature effectively captures the growth or decay of nonlinear intensity due to parameter variations. Furthermore, damping is shown to attenuate nonlinear effects owing to energy dissipation, whereas increased detuning leads to stronger nonlinear responses characterized by pronounced multi-valued behavior. These findings provide valuable insights into controlling and tuning the nonlinear vibration characteristics of SWBNNT-based nanostructures.
- 12 June 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Nonlinear Resonance Dynamics of SWBNNTs in Viscoelastic Media: Primary, Subharmonic, and Superharmonic Regimes
This study investigates the nonlinear vibrational behavior of single-walled boron nitride nanotubes (SWBNNTs) using a nonlinear Euler–Bernoulli beam model. The governing partial differential equations are reduced to a set of ordinary differential equations through Galerkin’s method employing trigonometric shape functions. The multiple time scales method is then applied to analyze the nonlinear frequency response under primary, subharmonic, and superharmonic resonances, and implicit analytical expressions for the frequency response are derived. A comprehensive parametric study is conducted to examine the influences of stiffness, excitation amplitude, damping coefficient, and detuning parameter on the nonlinear dynamic behavior. The results reveal that increased stiffness significantly suppresses nonlinear effects by enhancing resistance to deformation, while higher excitation amplitudes amplify nonlinear response intensity across all resonance cases. Subharmonic resonance exhibits response trends distinct from those of primary and superharmonic resonances, although their overall effectiveness remains comparable. Backbone curve curvature effectively captures the growth or decay of nonlinear intensity due to parameter variations. Furthermore, damping is shown to attenuate nonlinear effects owing to energy dissipation, whereas increased detuning leads to stronger nonlinear responses characterized by pronounced multi-valued behavior. These findings provide valuable insights into controlling and tuning the nonlinear vibration characteristics of SWBNNT-based nanostructures.
- 3 February 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (05)
Comparative hemodynamic remodeling induced by coil embolization in intracranial aneurysms: Computational study
This study evaluates the hemodynamic influence of endovascular coiling on four intracranial aneurysm types — ACA, MCA, BAS and ICA — using patient-specific CFD models with matched sac volumes. The analysis focuses on key biomechanical markers associated with aneurysm growth and rupture, including wall shear stress (WSS), oscillatory shear index (OSI), pressure and intra-saccular velocity structure. Unsteady, incompressible, non-Newtonian blood flow was simulated using the Casson model and rigid-wall assumptions. Coiling was represented through a porous-medium formulation, with permeability derived from coil geometry and Kozeny-based relations. Boundary conditions employed physiological inlet waveforms and zero-pressure outlets. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. Flow patterns, WSS, pressure, AWSS, OSI, iso-velocity surfaces and streamline structures were examined before and after coiling across three simulated cardiac cycles. In untreated aneurysms, strong inflow jets, elevated WSS and high OSI were observed, with substantial variability among ACA, MCA, BAS and ICA geometries. Coiling treatment significantly reduced intra-saccular velocity magnitudes, suppressed vortex formation and limited inflow penetration at the neck. WSS and AWSS decreased by more than 60–75% in all cases, while OSI was broadly reduced, indicating improved temporal shear stability. Pressure distributions became smoother and more uniform, reflecting coil-induced flow damping. The differences between aneurysm locations diminished considerably after coiling, demonstrating the homogenizing effect of porous resistance on hemodynamic behavior. Endovascular coiling consistently attenuates harmful hemodynamic conditions across four major aneurysm locations, producing lower shear stress, reduced oscillatory flow and stabilized intra-saccular pressure. These findings highlight the effectiveness of coiling in promoting a low-velocity, low-shear environment conducive to thrombosis and aneurysm healing, while emphasizing the value of CFD-based comparative analysis for understanding location-specific treatment responses.
- 3 February 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (05)
Comparative hemodynamic remodeling induced by coil embolization in intracranial aneurysms: Computational study
This study evaluates the hemodynamic influence of endovascular coiling on four intracranial aneurysm types — ACA, MCA, BAS and ICA — using patient-specific CFD models with matched sac volumes. The analysis focuses on key biomechanical markers associated with aneurysm growth and rupture, including wall shear stress (WSS), oscillatory shear index (OSI), pressure and intra-saccular velocity structure. Unsteady, incompressible, non-Newtonian blood flow was simulated using the Casson model and rigid-wall assumptions. Coiling was represented through a porous-medium formulation, with permeability derived from coil geometry and Kozeny-based relations. Boundary conditions employed physiological inlet waveforms and zero-pressure outlets. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. Flow patterns, WSS, pressure, AWSS, OSI, iso-velocity surfaces and streamline structures were examined before and after coiling across three simulated cardiac cycles. In untreated aneurysms, strong inflow jets, elevated WSS and high OSI were observed, with substantial variability among ACA, MCA, BAS and ICA geometries. Coiling treatment significantly reduced intra-saccular velocity magnitudes, suppressed vortex formation and limited inflow penetration at the neck. WSS and AWSS decreased by more than 60–75% in all cases, while OSI was broadly reduced, indicating improved temporal shear stability. Pressure distributions became smoother and more uniform, reflecting coil-induced flow damping. The differences between aneurysm locations diminished considerably after coiling, demonstrating the homogenizing effect of porous resistance on hemodynamic behavior. Endovascular coiling consistently attenuates harmful hemodynamic conditions across four major aneurysm locations, producing lower shear stress, reduced oscillatory flow and stabilized intra-saccular pressure. These findings highlight the effectiveness of coiling in promoting a low-velocity, low-shear environment conducive to thrombosis and aneurysm healing, while emphasizing the value of CFD-based comparative analysis for understanding location-specific treatment responses.
- 31 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Computational analysis of flow-induced stresses in cerebral aneurysms during normal and exercise conditions
This study numerically investigates the hemodynamic behavior of cerebral aneurysms under two distinct physiological states—rest and exercise—using a non-Newtonian Casson fluid model. Four patient-specific aneurysm geometries located in the anterior cerebral artery (ACA), middle cerebral artery (MCA), internal carotid artery (ICA) and basilar artery (BAS) were simulated using the finite-volume solver ANSYS Fluent. Blood was modeled as an incompressible Casson fluid with a hematocrit level of 0.42 and the vessel walls were assumed rigid (non-FSI). Transient simulations were performed for three cardiac cycles with a time step of 0.00297[ ]s. Time-dependent inlet mass flow and outlet pressure waveforms were applied to reproduce physiological pulsatility at both rest and exercise states.Results demonstrated that exercise significantly amplifies flow velocity, wall shear stress (WSS) and pressure throughout the aneurysm domain. The maximum and average WSS increased by more than threefold under exercise conditions, reaching peak systolic values up to 10[ ]Pa, while wall pressure rose proportionally with flow rate and systemic pressure. Time-averaged WSS (AWSS) and oscillatory shear index (OSI) analyses revealed that exercise enhances shear uniformity but reduces low-shear oscillatory regions, suggesting a shift toward more directional, high-energy flow. Increased vorticity and jet impingement during exercise further intensified the local hemodynamic stresses at the aneurysm neck. These findings highlight the critical influence of physiological activity on intra-aneurysmal flow dynamics and may provide insights into the biomechanical factors governing aneurysm growth and rupture risk.
- 31 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Computational analysis of flow-induced stresses in cerebral aneurysms during normal and exercise conditions
This study numerically investigates the hemodynamic behavior of cerebral aneurysms under two distinct physiological states—rest and exercise—using a non-Newtonian Casson fluid model. Four patient-specific aneurysm geometries located in the anterior cerebral artery (ACA), middle cerebral artery (MCA), internal carotid artery (ICA) and basilar artery (BAS) were simulated using the finite-volume solver ANSYS Fluent. Blood was modeled as an incompressible Casson fluid with a hematocrit level of 0.42 and the vessel walls were assumed rigid (non-FSI). Transient simulations were performed for three cardiac cycles with a time step of 0.00297[ ]s. Time-dependent inlet mass flow and outlet pressure waveforms were applied to reproduce physiological pulsatility at both rest and exercise states.Results demonstrated that exercise significantly amplifies flow velocity, wall shear stress (WSS) and pressure throughout the aneurysm domain. The maximum and average WSS increased by more than threefold under exercise conditions, reaching peak systolic values up to 10[ ]Pa, while wall pressure rose proportionally with flow rate and systemic pressure. Time-averaged WSS (AWSS) and oscillatory shear index (OSI) analyses revealed that exercise enhances shear uniformity but reduces low-shear oscillatory regions, suggesting a shift toward more directional, high-energy flow. Increased vorticity and jet impingement during exercise further intensified the local hemodynamic stresses at the aneurysm neck. These findings highlight the critical influence of physiological activity on intra-aneurysmal flow dynamics and may provide insights into the biomechanical factors governing aneurysm growth and rupture risk.
- 14 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Hemodynamic analysis of cerebral saccular aneurysms across sizes and cardiac cycle stages via computational technique
In the present study, the variations in hemodynamic parameters within distinct cerebral saccular aneurysms during different stages of the cardiac cycle are comprehensively investigated. By comparing these parameters, the research aims to elucidate potential differences in hemodynamic behavior across aneurysm types and cardiac cycle phases. A computational technique is applied for the evaluation of the blood flow inside cerebral aneurysms. The primary attention is to investigate the change of main hemodynamic factors related to the haemorrhage of the aneurysm in six different patients with different sac sizes. The Casson Model is used for the estimation of blood viscosity in our simulations. The findings offer insights into the hemodynamic intricacies of cerebral saccular aneurysms, shedding light on how these variations might influence the pathology and potential treatment strategies for such conditions. Our finding shows that the wall shear stress is high near the ostium region and increasing the sac volume decreases the critical high Wall shear stress region near the neck area.
- 14 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Hemodynamic analysis of cerebral saccular aneurysms across sizes and cardiac cycle stages via computational technique
In the present study, the variations in hemodynamic parameters within distinct cerebral saccular aneurysms during different stages of the cardiac cycle are comprehensively investigated. By comparing these parameters, the research aims to elucidate potential differences in hemodynamic behavior across aneurysm types and cardiac cycle phases. A computational technique is applied for the evaluation of the blood flow inside cerebral aneurysms. The primary attention is to investigate the change of main hemodynamic factors related to the haemorrhage of the aneurysm in six different patients with different sac sizes. The Casson Model is used for the estimation of blood viscosity in our simulations. The findings offer insights into the hemodynamic intricacies of cerebral saccular aneurysms, shedding light on how these variations might influence the pathology and potential treatment strategies for such conditions. Our finding shows that the wall shear stress is high near the ostium region and increasing the sac volume decreases the critical high Wall shear stress region near the neck area.