Khalil Hajlaoui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Khalil Hajlaoui has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Husam Rajab
College of Engineering, Department of Mechanical Engineering, Najran University, King Abdulaziz Road, P.O Box 1988, Najran, Saudi Arabia
4 shared publications - Zoubeir Tourki
University of Sousse
4 shared publications - Rifaqat Ali
Department of Mathematics, Applied College in Mohayil, Asir, King Khalid University, Abha, Saudi Arabia
3 shared publications A. R. Yavari
SIMaP-LTPCM, Institut National Polytechnique de Grenoble, Saint Martin d’Heres, France
2 shared publicationsAli Fawzi Al-Hussainy
College of Pharmacy, Ahl Al Bayt University, Kerbala, Iraq
2 shared publications- Hana Ihsan Hassan
Department of Radiology Techniques, Health and Medical Techniques College, Alnoor University, Nineveh, Iraq
2 shared publications
Latest Publications
- 12 June 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Nonlinear Resonance Dynamics of SWBNNTs in Viscoelastic Media: Primary, Subharmonic, and Superharmonic Regimes
This study investigates the nonlinear vibrational behavior of single-walled boron nitride nanotubes (SWBNNTs) using a nonlinear Euler–Bernoulli beam model. The governing partial differential equations are reduced to a set of ordinary differential equations through Galerkin’s method employing trigonometric shape functions. The multiple time scales method is then applied to analyze the nonlinear frequency response under primary, subharmonic, and superharmonic resonances, and implicit analytical expressions for the frequency response are derived. A comprehensive parametric study is conducted to examine the influences of stiffness, excitation amplitude, damping coefficient, and detuning parameter on the nonlinear dynamic behavior. The results reveal that increased stiffness significantly suppresses nonlinear effects by enhancing resistance to deformation, while higher excitation amplitudes amplify nonlinear response intensity across all resonance cases. Subharmonic resonance exhibits response trends distinct from those of primary and superharmonic resonances, although their overall effectiveness remains comparable. Backbone curve curvature effectively captures the growth or decay of nonlinear intensity due to parameter variations. Furthermore, damping is shown to attenuate nonlinear effects owing to energy dissipation, whereas increased detuning leads to stronger nonlinear responses characterized by pronounced multi-valued behavior. These findings provide valuable insights into controlling and tuning the nonlinear vibration characteristics of SWBNNT-based nanostructures.
- 12 June 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Structural Stability and Dynamics
Nonlinear Resonance Dynamics of SWBNNTs in Viscoelastic Media: Primary, Subharmonic, and Superharmonic Regimes
This study investigates the nonlinear vibrational behavior of single-walled boron nitride nanotubes (SWBNNTs) using a nonlinear Euler–Bernoulli beam model. The governing partial differential equations are reduced to a set of ordinary differential equations through Galerkin’s method employing trigonometric shape functions. The multiple time scales method is then applied to analyze the nonlinear frequency response under primary, subharmonic, and superharmonic resonances, and implicit analytical expressions for the frequency response are derived. A comprehensive parametric study is conducted to examine the influences of stiffness, excitation amplitude, damping coefficient, and detuning parameter on the nonlinear dynamic behavior. The results reveal that increased stiffness significantly suppresses nonlinear effects by enhancing resistance to deformation, while higher excitation amplitudes amplify nonlinear response intensity across all resonance cases. Subharmonic resonance exhibits response trends distinct from those of primary and superharmonic resonances, although their overall effectiveness remains comparable. Backbone curve curvature effectively captures the growth or decay of nonlinear intensity due to parameter variations. Furthermore, damping is shown to attenuate nonlinear effects owing to energy dissipation, whereas increased detuning leads to stronger nonlinear responses characterized by pronounced multi-valued behavior. These findings provide valuable insights into controlling and tuning the nonlinear vibration characteristics of SWBNNT-based nanostructures.
- 3 February 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (05)
Comparative hemodynamic remodeling induced by coil embolization in intracranial aneurysms: Computational study
This study evaluates the hemodynamic influence of endovascular coiling on four intracranial aneurysm types — ACA, MCA, BAS and ICA — using patient-specific CFD models with matched sac volumes. The analysis focuses on key biomechanical markers associated with aneurysm growth and rupture, including wall shear stress (WSS), oscillatory shear index (OSI), pressure and intra-saccular velocity structure. Unsteady, incompressible, non-Newtonian blood flow was simulated using the Casson model and rigid-wall assumptions. Coiling was represented through a porous-medium formulation, with permeability derived from coil geometry and Kozeny-based relations. Boundary conditions employed physiological inlet waveforms and zero-pressure outlets. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. Flow patterns, WSS, pressure, AWSS, OSI, iso-velocity surfaces and streamline structures were examined before and after coiling across three simulated cardiac cycles. In untreated aneurysms, strong inflow jets, elevated WSS and high OSI were observed, with substantial variability among ACA, MCA, BAS and ICA geometries. Coiling treatment significantly reduced intra-saccular velocity magnitudes, suppressed vortex formation and limited inflow penetration at the neck. WSS and AWSS decreased by more than 60–75% in all cases, while OSI was broadly reduced, indicating improved temporal shear stability. Pressure distributions became smoother and more uniform, reflecting coil-induced flow damping. The differences between aneurysm locations diminished considerably after coiling, demonstrating the homogenizing effect of porous resistance on hemodynamic behavior. Endovascular coiling consistently attenuates harmful hemodynamic conditions across four major aneurysm locations, producing lower shear stress, reduced oscillatory flow and stabilized intra-saccular pressure. These findings highlight the effectiveness of coiling in promoting a low-velocity, low-shear environment conducive to thrombosis and aneurysm healing, while emphasizing the value of CFD-based comparative analysis for understanding location-specific treatment responses.
- 3 February 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (05)
Comparative hemodynamic remodeling induced by coil embolization in intracranial aneurysms: Computational study
This study evaluates the hemodynamic influence of endovascular coiling on four intracranial aneurysm types — ACA, MCA, BAS and ICA — using patient-specific CFD models with matched sac volumes. The analysis focuses on key biomechanical markers associated with aneurysm growth and rupture, including wall shear stress (WSS), oscillatory shear index (OSI), pressure and intra-saccular velocity structure. Unsteady, incompressible, non-Newtonian blood flow was simulated using the Casson model and rigid-wall assumptions. Coiling was represented through a porous-medium formulation, with permeability derived from coil geometry and Kozeny-based relations. Boundary conditions employed physiological inlet waveforms and zero-pressure outlets. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. The simulations were performed using a finite-volume computational fluid dynamics framework implemented in ANSYS Fluent, solving the unsteady incompressible Navier–Stokes equations with a non-Newtonian Casson blood rheology. Endovascular coiling was modeled through a porous-medium formulation to account for coil-induced hydraulic resistance within the aneurysm sac. Flow patterns, WSS, pressure, AWSS, OSI, iso-velocity surfaces and streamline structures were examined before and after coiling across three simulated cardiac cycles. In untreated aneurysms, strong inflow jets, elevated WSS and high OSI were observed, with substantial variability among ACA, MCA, BAS and ICA geometries. Coiling treatment significantly reduced intra-saccular velocity magnitudes, suppressed vortex formation and limited inflow penetration at the neck. WSS and AWSS decreased by more than 60–75% in all cases, while OSI was broadly reduced, indicating improved temporal shear stability. Pressure distributions became smoother and more uniform, reflecting coil-induced flow damping. The differences between aneurysm locations diminished considerably after coiling, demonstrating the homogenizing effect of porous resistance on hemodynamic behavior. Endovascular coiling consistently attenuates harmful hemodynamic conditions across four major aneurysm locations, producing lower shear stress, reduced oscillatory flow and stabilized intra-saccular pressure. These findings highlight the effectiveness of coiling in promoting a low-velocity, low-shear environment conducive to thrombosis and aneurysm healing, while emphasizing the value of CFD-based comparative analysis for understanding location-specific treatment responses.
- 31 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Computational analysis of flow-induced stresses in cerebral aneurysms during normal and exercise conditions
This study numerically investigates the hemodynamic behavior of cerebral aneurysms under two distinct physiological states—rest and exercise—using a non-Newtonian Casson fluid model. Four patient-specific aneurysm geometries located in the anterior cerebral artery (ACA), middle cerebral artery (MCA), internal carotid artery (ICA) and basilar artery (BAS) were simulated using the finite-volume solver ANSYS Fluent. Blood was modeled as an incompressible Casson fluid with a hematocrit level of 0.42 and the vessel walls were assumed rigid (non-FSI). Transient simulations were performed for three cardiac cycles with a time step of 0.00297[ ]s. Time-dependent inlet mass flow and outlet pressure waveforms were applied to reproduce physiological pulsatility at both rest and exercise states.Results demonstrated that exercise significantly amplifies flow velocity, wall shear stress (WSS) and pressure throughout the aneurysm domain. The maximum and average WSS increased by more than threefold under exercise conditions, reaching peak systolic values up to 10[ ]Pa, while wall pressure rose proportionally with flow rate and systemic pressure. Time-averaged WSS (AWSS) and oscillatory shear index (OSI) analyses revealed that exercise enhances shear uniformity but reduces low-shear oscillatory regions, suggesting a shift toward more directional, high-energy flow. Increased vorticity and jet impingement during exercise further intensified the local hemodynamic stresses at the aneurysm neck. These findings highlight the critical influence of physiological activity on intra-aneurysmal flow dynamics and may provide insights into the biomechanical factors governing aneurysm growth and rupture risk.
- 31 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Computational analysis of flow-induced stresses in cerebral aneurysms during normal and exercise conditions
This study numerically investigates the hemodynamic behavior of cerebral aneurysms under two distinct physiological states—rest and exercise—using a non-Newtonian Casson fluid model. Four patient-specific aneurysm geometries located in the anterior cerebral artery (ACA), middle cerebral artery (MCA), internal carotid artery (ICA) and basilar artery (BAS) were simulated using the finite-volume solver ANSYS Fluent. Blood was modeled as an incompressible Casson fluid with a hematocrit level of 0.42 and the vessel walls were assumed rigid (non-FSI). Transient simulations were performed for three cardiac cycles with a time step of 0.00297[ ]s. Time-dependent inlet mass flow and outlet pressure waveforms were applied to reproduce physiological pulsatility at both rest and exercise states.Results demonstrated that exercise significantly amplifies flow velocity, wall shear stress (WSS) and pressure throughout the aneurysm domain. The maximum and average WSS increased by more than threefold under exercise conditions, reaching peak systolic values up to 10[ ]Pa, while wall pressure rose proportionally with flow rate and systemic pressure. Time-averaged WSS (AWSS) and oscillatory shear index (OSI) analyses revealed that exercise enhances shear uniformity but reduces low-shear oscillatory regions, suggesting a shift toward more directional, high-energy flow. Increased vorticity and jet impingement during exercise further intensified the local hemodynamic stresses at the aneurysm neck. These findings highlight the critical influence of physiological activity on intra-aneurysmal flow dynamics and may provide insights into the biomechanical factors governing aneurysm growth and rupture risk.
- 14 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Hemodynamic analysis of cerebral saccular aneurysms across sizes and cardiac cycle stages via computational technique
In the present study, the variations in hemodynamic parameters within distinct cerebral saccular aneurysms during different stages of the cardiac cycle are comprehensively investigated. By comparing these parameters, the research aims to elucidate potential differences in hemodynamic behavior across aneurysm types and cardiac cycle phases. A computational technique is applied for the evaluation of the blood flow inside cerebral aneurysms. The primary attention is to investigate the change of main hemodynamic factors related to the haemorrhage of the aneurysm in six different patients with different sac sizes. The Casson Model is used for the estimation of blood viscosity in our simulations. The findings offer insights into the hemodynamic intricacies of cerebral saccular aneurysms, shedding light on how these variations might influence the pathology and potential treatment strategies for such conditions. Our finding shows that the wall shear stress is high near the ostium region and increasing the sac volume decreases the critical high Wall shear stress region near the neck area.
- 14 January 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics C
- Vol. 38 (04)
Hemodynamic analysis of cerebral saccular aneurysms across sizes and cardiac cycle stages via computational technique
In the present study, the variations in hemodynamic parameters within distinct cerebral saccular aneurysms during different stages of the cardiac cycle are comprehensively investigated. By comparing these parameters, the research aims to elucidate potential differences in hemodynamic behavior across aneurysm types and cardiac cycle phases. A computational technique is applied for the evaluation of the blood flow inside cerebral aneurysms. The primary attention is to investigate the change of main hemodynamic factors related to the haemorrhage of the aneurysm in six different patients with different sac sizes. The Casson Model is used for the estimation of blood viscosity in our simulations. The findings offer insights into the hemodynamic intricacies of cerebral saccular aneurysms, shedding light on how these variations might influence the pathology and potential treatment strategies for such conditions. Our finding shows that the wall shear stress is high near the ostium region and increasing the sac volume decreases the critical high Wall shear stress region near the neck area.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
Advanced Fin Design for Efficient Heat Transfer in Double‐Pipe Latent Heat Thermal Storage: A Comparative Study of Straight and Inclined Multielement Fins
The inherently low thermal conductivity of phase change materials (PCMs) in latent heat thermal energy storage (LHTES) systems hampers efficient heat transfer during melting and solidification processes. This study aims to enhance PCM thermal performance by optimizing fin geometry within a vertical double‐pipe heat exchanger, with a focus on inclined multielement fin configurations. Novelty lies in the systematic investigation of fin orientation (30°, 35°, and 40°), number, thickness, and flow direction through detailed two‐dimensional axisymmetric simulations using ANSYS Fluent. The model incorporates buoyancy‐driven convection via the Boussinesq approximation and has been validated against experimental benchmarks with <3% deviation. Results reveal that an inclined three‐element fin configuration at a 40° angle (Case 3‐3) outperforms conventional straight fins (Case 0), increasing melting rate by 6.5% (48.16 W vs. 45.24 W) and reducing melting time by 2.3% (2470 s vs. 2529 s). During solidification, Case 3‐3 also demonstrates superior performance with a 20.8% higher discharging rate (35.42 W vs. 28.05 W) and 18.4% shorter solidification time (3497 s vs. 4352 s). Excessive fin thickness (up to 1.2x baseline) and suboptimal flow direction were shown to reduce performance by up to 25.5%. These findings provide critical insights for thermal system designers by demonstrating how geometric tailoring of fins can substantially boost energy storage and retrieval rates in PCM‐based systems. The proposed configurations offer a practical route to more compact, efficient, and responsive LHTES systems for renewable heating, industrial recovery, and building applications.
- 1 January 2026
- Published by Wiley in International Journal of Energy Research
- Vol. 2026 (1)
Open AccessAdvanced Fin Design for Efficient Heat Transfer in Double‐Pipe Latent Heat Thermal Storage: A Comparative Study of Straight and Inclined Multielement Fins
The inherently low thermal conductivity of phase change materials (PCMs) in latent heat thermal energy storage (LHTES) systems hampers efficient heat transfer during melting and solidification processes. This study aims to enhance PCM thermal performance by optimizing fin geometry within a vertical double‐pipe heat exchanger, with a focus on inclined multielement fin configurations. Novelty lies in the systematic investigation of fin orientation (30°, 35°, and 40°), number, thickness, and flow direction through detailed two‐dimensional axisymmetric simulations using ANSYS Fluent. The model incorporates buoyancy‐driven convection via the Boussinesq approximation and has been validated against experimental benchmarks with <3% deviation. Results reveal that an inclined three‐element fin configuration at a 40° angle (Case 3‐3) outperforms conventional straight fins (Case 0), increasing melting rate by 6.5% (48.16 W vs. 45.24 W) and reducing melting time by 2.3% (2470 s vs. 2529 s). During solidification, Case 3‐3 also demonstrates superior performance with a 20.8% higher discharging rate (35.42 W vs. 28.05 W) and 18.4% shorter solidification time (3497 s vs. 4352 s). Excessive fin thickness (up to 1.2x baseline) and suboptimal flow direction were shown to reduce performance by up to 25.5%. These findings provide critical insights for thermal system designers by demonstrating how geometric tailoring of fins can substantially boost energy storage and retrieval rates in PCM‐based systems. The proposed configurations offer a practical route to more compact, efficient, and responsive LHTES systems for renewable heating, industrial recovery, and building applications.
- 5 November 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 193
Optimizing fuel-air mixing using double strut injector configurations in supersonic combustion
- 5 November 2025
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 193
Optimizing fuel-air mixing using double strut injector configurations in supersonic combustion
- Open Access
- 1 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (12) , 125207
Hydrogen-induced softening and hardening of Zr-based amorphous alloy: dependence on the hydrogen content and mobility
- 1 December 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (12) , 125207
Open AccessHydrogen-induced softening and hardening of Zr-based amorphous alloy: dependence on the hydrogen content and mobility
- Open Access
- 16 August 2017
- Published by MathDoc/Centre Mersenne in Comptes Rendus Mécanique
- Vol. 345 (11) , 797-804
On a new electromechanical switch using the reversible wavy elastic response of metallic glass ribbons
- 16 August 2017
- Published by MathDoc/Centre Mersenne in Comptes Rendus Mécanique
- Vol. 345 (11) , 797-804
Open AccessOn a new electromechanical switch using the reversible wavy elastic response of metallic glass ribbons
- Open Access
On the Modelling of the Transient Flow Behavior of Metallic Glasses: Analogy with Portevin-Le Chatelier Effect
A constitutive model for serrated flow together with a finite element (FE) analysis was developed to simulate discontinuous yielding behavior of metallic glasses, commonly known as serrated flow inhomogeneous deformation. The constructed model is based on transient behavior resulting from the time dependence of the flow defect concentration in the shear bands. The computed results of stress-strain curves were consistent with the experimental data. The main features of the serrated flow effect have also been exhibited by the model.
Open AccessOn the Modelling of the Transient Flow Behavior of Metallic Glasses: Analogy with Portevin-Le Chatelier Effect
A constitutive model for serrated flow together with a finite element (FE) analysis was developed to simulate discontinuous yielding behavior of metallic glasses, commonly known as serrated flow inhomogeneous deformation. The constructed model is based on transient behavior resulting from the time dependence of the flow defect concentration in the shear bands. The computed results of stress-strain curves were consistent with the experimental data. The main features of the serrated flow effect have also been exhibited by the model.
- 17 September 2013
- Published by Elsevier in Acta Metallurgica Sinica (English Letters)
- Vol. 26 (5) , 503-508
Serrated flow model for metallic glasses under compressive loading
- 17 September 2013
- Published by Elsevier in Acta Metallurgica Sinica (English Letters)
- Vol. 26 (5) , 503-508
Serrated flow model for metallic glasses under compressive loading