Muhammad Hafizuddin Al-Helmy Nouxman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Muhammad Hafizuddin Al-Helmy Nouxman has a total of 588 co-authors. Here are the top co-authors by number of shared publications:
- A. B. Kaliyar
The Belle II Collaboration)
1 shared publication - A. Baur
The Belle II Collaboration)
1 shared publication - A. Beaubien
The Belle II Collaboration)
1 shared publication - A. Bobrov
The Belle II Collaboration)
1 shared publication - A. Bondar
Budker Institute of Nuclear Physics
1 shared publication - A. De Yta-Hernandez
Centro de Investigacion y de Estudios Avanzados del Instituto Politecnico Nacional, Av. IPN 2508, San Pedro Zacatenco, Mexico City 07360, Mexico
1 shared publication
Latest Publications
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (6) , 7989-7996
Screen-Printed Organic Electrochemical Transistor With 3-D-Printed Hollow Microneedle for a Fully Integrated Glucose Sensor
In this work, a novel fully integrated glucose sensor based on organic electrochemical transistor (OECT) has been proposed through feasible printing on a flexible substrate. The fully integrated glucose sensor incorporates: 1) a screen-printed OECT featuring poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) channel functionalized with a chitosan–titanium dioxide (CS-TiO₂) nanocomposite and glucose oxidase (GOx) enzyme to enable glucose detection; 2) a 3D-printed 3x3 hollow microneedle (HMN) platform with reservoir pad for minimally invasive sampling; and 3) a flexible compact wireless interfacing circuit for glucose analysis. Mechanical and electrical stability are investigated on the OECT device after 100 bending cycles and over a week of testing on a curved surface. With respect to glucose, the OECT showed a strong linear response in between 0.01 to 30 mM (r² = 0.993), a high sensitivity of 6.01 μA·mM⁻¹·cm⁻², and good selectivity against ascorbic acid and uric acid. Upon integration, the integrated glucose sensor achieved a rapid response time of under 20 s when tested on an agar gel-based skin model. The output currents were calibrated and then verified within the glucose range of 1–10 mM, with a total reading time of less than 120 s, demonstrating good accuracy. Overall, the implementation of OECT coupled with HMN offers a promising platform for a fully integrated glucose sensor, with great potential towards commercialization.
- 6 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (6) , 7989-7996
Screen-Printed Organic Electrochemical Transistor With 3-D-Printed Hollow Microneedle for a Fully Integrated Glucose Sensor
In this work, a novel fully integrated glucose sensor based on organic electrochemical transistor (OECT) has been proposed through feasible printing on a flexible substrate. The fully integrated glucose sensor incorporates: 1) a screen-printed OECT featuring poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) channel functionalized with a chitosan–titanium dioxide (CS-TiO₂) nanocomposite and glucose oxidase (GOx) enzyme to enable glucose detection; 2) a 3D-printed 3x3 hollow microneedle (HMN) platform with reservoir pad for minimally invasive sampling; and 3) a flexible compact wireless interfacing circuit for glucose analysis. Mechanical and electrical stability are investigated on the OECT device after 100 bending cycles and over a week of testing on a curved surface. With respect to glucose, the OECT showed a strong linear response in between 0.01 to 30 mM (r² = 0.993), a high sensitivity of 6.01 μA·mM⁻¹·cm⁻², and good selectivity against ascorbic acid and uric acid. Upon integration, the integrated glucose sensor achieved a rapid response time of under 20 s when tested on an agar gel-based skin model. The output currents were calibrated and then verified within the glucose range of 1–10 mM, with a total reading time of less than 120 s, demonstrating good accuracy. Overall, the implementation of OECT coupled with HMN offers a promising platform for a fully integrated glucose sensor, with great potential towards commercialization.
- Open AccessReconstruction of $B \to ρ\ell ν_\ell$ decays identified using hadronic decays of the recoil $B$ meson in 2019 -- 2021 Belle II dataWe present results on the semileptonic decays $B^0 \to \rho^- \ell^+ \nu_\ell$ and $B^+ \to \rho^0 \ell^+ \nu_\ell$ in a sample corresponding to 189.9/fb of Belle II data at the SuperKEKB $e^- e^+$ collider. Signal decays are identified using full reconstruction of the recoil $B$ meson in hadronic final states. We determine the total branching fractions via fits to the distributions of the square of the "missing" mass in the event and the dipion mass in the signal candidate and find ${\mathcal{B}(B^0\to\rho^-\ell^+ \nu_\ell) = (4.12 \pm 0.64(\mathrm{stat}) \pm 1.16(\mathrm{syst})) \times 10^{-4}}$ and ${\mathcal{B}({B^+\to\rho^0\ell^+\nu_\ell}) = (1.77 \pm 0.23 (\mathrm{stat}) \pm 0.36 (\mathrm{syst})) \times 10^{-4}}$ where the dominant systematic uncertainty comes from modeling the nonresonant $B\to (\pi\pi)\ell^+\nu_\ell$ contribution.Open AccessReconstruction of $B \to ρ\ell ν_\ell$ decays identified using hadronic decays of the recoil $B$ meson in 2019 -- 2021 Belle II dataWe present results on the semileptonic decays $B^0 \to \rho^- \ell^+ \nu_\ell$ and $B^+ \to \rho^0 \ell^+ \nu_\ell$ in a sample corresponding to 189.9/fb of Belle II data at the SuperKEKB $e^- e^+$ collider. Signal decays are identified using full reconstruction of the recoil $B$ meson in hadronic final states. We determine the total branching fractions via fits to the distributions of the square of the "missing" mass in the event and the dipion mass in the signal candidate and find ${\mathcal{B}(B^0\to\rho^-\ell^+ \nu_\ell) = (4.12 \pm 0.64(\mathrm{stat}) \pm 1.16(\mathrm{syst})) \times 10^{-4}}$ and ${\mathcal{B}({B^+\to\rho^0\ell^+\nu_\ell}) = (1.77 \pm 0.23 (\mathrm{stat}) \pm 0.36 (\mathrm{syst})) \times 10^{-4}}$ where the dominant systematic uncertainty comes from modeling the nonresonant $B\to (\pi\pi)\ell^+\nu_\ell$ contribution.