Screen-Printed Organic Electrochemical Transistor With 3-D-Printed Hollow Microneedle for a Fully Integrated Glucose Sensor
Authors:
- Fazliyatul Azwa Md RezaliFRFazliyatul Azwa Md Rezali
- Sharifah Fatmadiana Wan Muhamad HattaSHSharifah Fatmadiana Wan Muhamad Hatta
- Norhayati SoinNSNorhayati Soin
- Muhammad Hafizuddin Al-Helmy NouxmanMNMuhammad Hafizuddin Al-Helmy Nouxman
- Ahmad Syafiq Aiman A. BakarABAhmad Syafiq Aiman A. Bakar
- Li-Ya MaLMLi-Ya Ma
- 6 February 2026
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (6) , 7989-7996
Abstract
In this work, a novel fully integrated glucose sensor based on organic electrochemical transistor (OECT) has been proposed through feasible printing on a flexible substrate. The fully integrated glucose sensor incorporates: 1) a screen-printed OECT featuring poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) channel functionalized with a chitosan–titanium dioxide (CS-TiO₂) nanocomposite and glucose oxidase (GOx) enzyme to enable glucose detection; 2) a 3D-printed 3x3 hollow microneedle (HMN) platform with reservoir pad for minimally invasive sampling; and 3) a flexible compact wireless interfacing circuit for glucose analysis. Mechanical and electrical stability are investigated on the OECT device after 100 bending cycles and over a week of testing on a curved surface. With respect to glucose, the OECT showed a strong linear response in between 0.01 to 30 mM (r² = 0.993), a high sensitivity of 6.01 μA·mM⁻¹·cm⁻², and good selectivity against ascorbic acid and uric acid. Upon integration, the integrated glucose sensor achieved a rapid response time of under 20 s when tested on an agar gel-based skin model. The output currents were calibrated and then verified within the glucose range of 1–10 mM, with a total reading time of less than 120 s, demonstrating good accuracy. Overall, the implementation of OECT coupled with HMN offers a promising platform for a fully integrated glucose sensor, with great potential towards commercialization.Keywords
Funding Information
- Universiti Malaya Centre of Research Grant 2024 (UM.0000290/HRU.RC)
- Collaborative Research in Engineering, Science & Technology Center
This publication has 73 references indexed in Scilit:
- Research Progress in Wearable Microneedle Sensors for Health AnalysisAdvanced Sensor Research, 2025
- Characterization of 3D-Printed Hollow Microneedle Array Towards Analyte Sampling and Detection2025
- High gain transimpedance amplification for wireless glucose monitoring in a wearable health sensor systemAnalog Integrated Circuits and Signal Processing, 2024
- Remote‐Controlled Sensing and Drug Delivery via 3D‐Printed Hollow MicroneedlesAdvanced Healthcare Materials, 2024
- A Performance Comparison Between Organic Electrochemical Transistor and Electrode Configurations for Enzymatic SensingAdvanced Sensor Research, 2024
- A Wearable Touch‐Activated Device Integrated with Hollow Microneedles for Continuous Sampling and Sensing of Dermal Interstitial Fluid (Adv. Mater. 2/2024)Advanced Materials, 2024
- Electrochemically activated polyaniline based ambipolar organic electrochemical transistorElectrochemical Science Advances, 2021
- Fabrication of screen-printed electrodes: opportunities and challengesJournal of Materials Science, 2021
- Degradation of water-soluble methyl orange in visible light with the use of silver and copper co-doped TiO2 nanoparticlesJournal of Materials Science: Materials in Electronics, 2016
- A glucose sensor via stable immobilization of the GOx enzyme on an organic transistor using a polymer brushJournal of Polymer Science Part A: Polymer Chemistry, 2014